Measurement of ethyl methanesulfonate in human plasma and breast milk samples using high-performance liquid chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry

被引:4
|
作者
Montesano, M. Angela [1 ]
Whitehead, Ralph D., Jr. [1 ]
Jayatilaka, Nayana K. [1 ]
Kuklenyik, Peter [1 ]
Davis, Mark D. [1 ]
Needham, Larry L. [1 ]
Barr, Dana Boyd [1 ]
机构
[1] Ctr Dis Control & Prevent, CDC, Natl Ctr Environm Hlth, Div Sci Lab, Atlanta, GA 30341 USA
关键词
Ethyl methanesulfonate; EMS; HPLC; Mass spectrometry; Electrospray ionization; GC-MS METHOD; METHYL METHANESULFONATE; GAS-CHROMATOGRAPHY; METHANE SULFONATE; DRUG SUBSTANCES; VALIDATION; MESYLATE; SALT; ACID;
D O I
10.1016/j.jpba.2009.12.030
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ethyl methanesulfonate (EMS) is a mesylate ester, which is known to be a potent mutagen, teratogen, and possibly carcinogen. Mesylate esters have been found in pharmaceuticals as contaminants formed during the manufacturing process and may potentially pose an exposure hazard to humans. We have developed and validated a method for detection of trace amounts (ng/ml levels) of EMS in human plasma and breast milk. The samples were extracted by matrix solid-phase dispersion with ethyl acetate using Hydromatrix (TM) and the ASE 200 Accelerated Solvent Extractor. The extracts were separated by high-performance liquid chromatography (HPLC) using a HILIC column. The detection was performed with a triple quadrupole mass spectrometer (TSQ Quantum Ultra, Thermo Electron Corporation) using atmospheric pressure chemical ionization in negative-ion mode and multiple reaction monitoring. The use of a surrogate internal standard in combination with HPLC-MS/MS provided a high degree of accuracy and precision. The extraction efficiency was greater than 70%. Repeated analyses of plasma and breast milk samples spiked with high (100 ng/ml), medium (50 ng/ml) and low (5 ng/ml) concentrations of the analytes gave relative standard deviations of less than 12%. The limits of detection were in the range of 0.5-0.9 ng/ml for both matrices. Published by Elsevier B.V.
引用
收藏
页码:260 / 264
页数:5
相关论文
共 50 条
  • [41] Determination of plasticizers by high-performance liquid chromatography and atmospheric pressure chemical ionization mass spectrometry in water and sediment samples
    Gimeno, RA
    Marcé, RM
    Borrull, F
    CHROMATOGRAPHIA, 2003, 58 (1-2) : 37 - 41
  • [42] Determination of Plasticizers by High-Performance Liquid Chromatography and Atmospheric Pressure Chemical Ionization Mass Spectrometry in Water and Sediment Samples
    R. A. Gimeno
    R. M. Marcé
    F. Borrull
    Chromatographia, 2003, 58 : 37 - 41
  • [43] Determination of eight herbicide residues in foodstuffs of plant origin by gas chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry
    Yang, Zhijin
    Lin, Binbin
    Huang, Xuliang
    Shi, Bing
    Ma, Qiang
    Han, Chao
    Shen, Yan
    MICROCHEMICAL JOURNAL, 2023, 193
  • [44] High-performance liquid chromatography-atmospheric pressure photoionization/tandem mass spectrometric analysis for small molecules in plasma
    Hsieh, YS
    Merkle, K
    Wang, GF
    Brisson, JM
    Korfmacher, WA
    ANALYTICAL CHEMISTRY, 2003, 75 (13) : 3122 - 3127
  • [45] Characterization of plant oils on a monolithic silica column by high-performance liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry
    Jakab, A
    Forgács, E
    CHROMATOGRAPHIA, 2002, 56 (1) : S69 - S73
  • [46] Monitoring of olanzapine in serum by liquid chromatography-atmospheric pressure chemical ionization mass spectrometry
    Bogusz, MJ
    Krüger, KD
    Maier, RD
    Erkwoh, R
    Tuchtenhagen, F
    JOURNAL OF CHROMATOGRAPHY B, 1999, 732 (02): : 257 - 269
  • [47] Liquid chromatography atmospheric pressure chemical ionization tandem mass spectrometry method for the quantification of pregabalin in human plasma
    Nirogi, Ramakrishna
    Kandikere, Vishwottam
    Mudigonda, Koteshwara
    Komarneni, Prashanth
    Aleti, Raghupathi
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (30): : 3899 - 3906
  • [48] Determination of vitamin K encapsulated into lipid nanocarriers by dispersive liquid-liquid microextraction combined with liquid chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry
    Yoo, Guijae
    Kim, Tae-Eun
    Lee, Min Hyeock
    Kim, Bum-Keun
    Jang, Hae Won
    FOOD SCIENCE & NUTRITION, 2023, 11 (02): : 688 - 695
  • [49] Analysis of Ginsenosides in Ginseng by Liquid Chromatography-Atmospheric Pressure Chemical Ionization Mass Spectrometry
    Ma Xiaoqiong
    Xu Qing
    Liang Xinmiao
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2005, 23 (04) : 389 - 393
  • [50] Determination of duloxetine in human plasma by liquid chromatography with atmospheric pressure ionization-tandem mass spectrometry and its application to pharmacokinetic study
    Selvan, P. Senthamil
    Gowda, K. Veeran
    Mandal, U.
    Solomon, W. D. Sam
    Pal, T. K.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 858 (1-2): : 269 - 275