THE EFFECT OF REFRIGERANT OUTLET TEMPERATURE FOR EXERGY EFFICIENCY OF HEAT PUMPS USING CO2

被引:0
|
作者
Ozgur, Arif Emre [1 ]
Bayrakci, Hilmi Cenk [2 ]
机构
[1] Suleyman Demirel Univ, Tekn Egitim Fak, Makine Egitimi Bolumu, TR-32260 Isparta, Turkey
[2] Suleyman Demirel Univ, Senirkent Meslek Yuksek Okulu Iklimlendirme Sogut, TR-32260 Isparta, Turkey
关键词
CO2; Transcritical; Heat pump; Exergy; Efficiency; CARBON-DIOXIDE; PRESSURES; CYCLES;
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
Because of the global warming, usage of natural refrigerants is being common in large scale. CO, cooling systems especially preferred at vehicle air conditioners and hot water heat pump applications. In this study, a single stage heat pump using CO2 refrigerant and having transcritical cycle is theoretically modeled. The effect of gas cooler outlet temperature for exergetic efficiency of heat pump is presented. Range of evaporating temperature is selected between -10 and +10 C degrees values. Calculations are made by software (EES-Engineering Equation Solver), and results are presented graphically.
引用
收藏
页码:73 / 78
页数:6
相关论文
共 50 条
  • [41] Effects of refrigerant charge amount on the performance of a transcritical CO2 heat pump
    Cho, HY
    Ryu, CG
    Kim, YC
    Kim, HY
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (08): : 1266 - 1273
  • [42] Efficiency of vapor compression heat pumps based on non-azeotropic refrigerant mixtures
    Mezentseva N.N.
    [J]. Thermophysics and Aeromechanics, 2011, 18 (2) : 323 - 330
  • [43] Optimization of Refrigerant Charge in Transcritical CO2 Heat Pump Water Heater
    He, Yu-Jia
    Liang, Xing-Yu
    Cheng, Jia-Hao
    Zhang, Chun-Lu
    [J]. Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2021, 42 (04): : 824 - 827
  • [44] A Simulation Model for CO2 Solar-Assisted Heat Pumps
    Neto, Carlos Boabaid
    de Abreu, Samuel L.
    Goncalves, Joaquim M.
    de Noni, Bruna
    [J]. PROCEEDINGS OF THE ISES SOLAR WORLD CONFERENCE 2019 AND THE IEA SHC SOLAR HEATING AND COOLING CONFERENCE FOR BUILDINGS AND INDUSTRY 2019, 2019, : 145 - 156
  • [45] The potential for CO2 heat pumps in the South African industrial sector
    Kaiser, Werner H.
    van Eldik, Martin
    [J]. PROCEEDINGS OF THE 13TH CONFERENCE ON THE INDUSTRIAL AND COMMERCIAL USE OF ENERGY, 2015, : 70 - 75
  • [46] Ship transport of CO2 -: Technical solutions and analysis of costs, energy utilization, exergy efficiency and CO2 emissions
    Aspelund, A.
    Molnvik, M. J.
    De Koeijer, G.
    [J]. CHEMICAL ENGINEERING RESEARCH & DESIGN, 2006, 84 (A9): : 847 - 855
  • [47] Exergy Efficiency and COP Improvement of a CO2 Transcritical Heat Pump System by Replacing an Expansion Valve with a Tesla Turbine
    Aghagoli, Abbas
    Sorin, Mikhail
    Khennich, Mohammed
    [J]. ENERGIES, 2022, 15 (14)
  • [48] Energy and exergy analysis of an air-source heat pump water heater system using CO2/R170 mixture as an azeotropy refrigerant for sustainable development
    Wang, Dong
    Liu, Yaru
    Kou, Zunli
    Yao, Lifang
    Lu, Yuehong
    Tao, Leren
    Xia, Peng
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 106 : 628 - 638
  • [49] Moderately high temperature water source heat-pumps using a near-azeotropic refrigerant mixture
    Liu, NX
    Lin, S
    Han, LZ
    Zhu, MS
    [J]. APPLIED ENERGY, 2005, 80 (04) : 435 - 447
  • [50] Photocatalytic reduction of CO2 under supercritical CO2 conditions: Effect of pressure, temperature, and solvent on catalytic efficiency
    Kawanami, Hajime
    Grills, David C.
    Ishizaka, Takayuki
    Chatterjee, Maya
    Suzuki, Akira
    [J]. JOURNAL OF CO2 UTILIZATION, 2013, 3-4 : 93 - 97