THE EFFECT OF REFRIGERANT OUTLET TEMPERATURE FOR EXERGY EFFICIENCY OF HEAT PUMPS USING CO2

被引:0
|
作者
Ozgur, Arif Emre [1 ]
Bayrakci, Hilmi Cenk [2 ]
机构
[1] Suleyman Demirel Univ, Tekn Egitim Fak, Makine Egitimi Bolumu, TR-32260 Isparta, Turkey
[2] Suleyman Demirel Univ, Senirkent Meslek Yuksek Okulu Iklimlendirme Sogut, TR-32260 Isparta, Turkey
关键词
CO2; Transcritical; Heat pump; Exergy; Efficiency; CARBON-DIOXIDE; PRESSURES; CYCLES;
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
Because of the global warming, usage of natural refrigerants is being common in large scale. CO, cooling systems especially preferred at vehicle air conditioners and hot water heat pump applications. In this study, a single stage heat pump using CO2 refrigerant and having transcritical cycle is theoretically modeled. The effect of gas cooler outlet temperature for exergetic efficiency of heat pump is presented. Range of evaporating temperature is selected between -10 and +10 C degrees values. Calculations are made by software (EES-Engineering Equation Solver), and results are presented graphically.
引用
收藏
页码:73 / 78
页数:6
相关论文
共 50 条
  • [1] Thermodynamical appraisal of heat pumps with CO2 refrigerant
    Chumak, IG
    Onistchenko, VP
    Zagoruchenko, NV
    Kustovsky, VG
    Kurbatov, AV
    [J]. APPLICATIONS FOR NATURAL REFRIGERANTS, 1996, : 633 - 637
  • [2] Exergy modelling of vapour compression heat pumps using refrigerant mixtures
    Stegou-Sagia, Athina
    Papadaki, Argyro
    [J]. INTERNATIONAL JOURNAL OF EXERGY, 2006, 3 (03) : 305 - 322
  • [3] On intrinsic exergy efficiency and heat pumps
    Labidi, J
    Boulet, E
    Paris, J
    [J]. CHEMICAL ENGINEERING RESEARCH & DESIGN, 2000, 78 (A2): : 180 - 183
  • [4] The effect of air humidity on the exergy efficiency of domestic heat pumps
    Zevenhoven, Ron
    Arnas, Ozer
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2020, 221
  • [5] Numerical Investigation of the Effect of Using CO2 as the Refrigerant in a Heat Pump Tumble Dryer System
    Erdem, Serkan
    Heperkan, Hasan
    [J]. DRYING TECHNOLOGY, 2014, 32 (16) : 1923 - 1930
  • [6] Experimental performance evaluation of heat pump by using CO2 as a refrigerant
    Venkatesh, V. K.
    Basavaraju, M. G.
    Rao, K. V. Sreenivas
    [J]. INTERNATIONAL CONFERENCE ON ADVANCES IN MATERIALS AND MANUFACTURING APPLICATIONS (ICONAMMA-2016), 2016, 149
  • [7] Research on Condensation Pressure and Temperature of Heat Pumps Using Blends of CO2 with Butane and Isobutane
    Zhang, Xianping
    Fan, Xiaowei
    Wei, Xinli
    Wang, Fang
    Zhang, Xiaojing
    [J]. PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 2: HVAC&R COMPONENT AND ENERGY SYSTEM, 2014, 262 : 791 - 797
  • [8] A novel control method for the automotive CO2 heat pumps under inappropriate refrigerant charge conditions
    Jia, Fan
    Yin, Xiang
    Cao, Feng
    Fang, Jianmin
    Wang, Anci
    Wang, Xixi
    Yang, Lichen
    [J]. ENERGY, 2024, 286
  • [9] Exergy-Optimum coupling of radiant panels with heat pumps for minimum CO2 emission responsibility
    Kilkis, Birol
    [J]. ENERGY CONVERSION AND MANAGEMENT-X, 2023, 20
  • [10] High temperature heat pumps for industrial heating processes using water as refrigerant
    Wang, Ruzhu
    Yan, Hongzhi
    Wu, Di
    Jiang, Jiatong
    Dong, Yixiu
    [J]. Energy, 2024, 313