Highly Selective Catalytic Spectrophotometric Determination of Copper in Water Samples

被引:0
|
作者
Bagheri, H. [1 ]
Tabatabaee, M. [1 ]
Kerdegari, A. A. [1 ]
Shahvazian, M. [1 ]
Shishehbore, M. R. [1 ]
机构
[1] Islamic Azad Univ, Yazd Branch, Dept Chem, Yazd, Iran
关键词
Kinetic; Spectrophotometric method; Copper determination; o-Phenanthroline; Thionine; SOLID-PHASE EXTRACTION; TRACE AMOUNTS; MASS-SPECTROMETRY; HYDROGEN-PEROXIDE; KINETIC METHOD; OXIDATION; THIONINE; VANADIUM; NICKEL; SILVER;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A simple, rapid and sensitive method has been developed for determination of trace amounts of copper(II) (1-160 ng mL(-1)) based on it's catalytic effect on the oxidation of thionine by hydrogen peroxide in an alkaline media and in the presence of o-phenanthroline as an activator. The reaction is monitored spectrophotometrically by measuring the decrease in absorbance of thionine at 600 nm by the fixed time method. The detection limit is 0.7 ng mL(-1) and relative standard deviation for ten replicate determinations of 2, 20, 50 and 100 ng mL(-1) copper were 1.71, 1.2, 0.98 and 0.75%, respectively. The proposed method is sensitive. accurate and tolerant to many foreign substances and all the reagents used are stable under the conditions. Moreover, the method is easy to perform for the determination of copper in real samples.
引用
收藏
页码:661 / 668
页数:8
相关论文
共 50 条