Design and simulation of a life detection system based on detection of the heart beat using Doppler frequency

被引:1
|
作者
Izadi, A. [1 ]
Ghatan, Z.
Vahdat, B. Vosoughi
Farzaneh, F.
机构
[1] Sharif Univ Technol, Dept Biomed Engn, Tehran, Iran
[2] Univ Tehran, Dept Elect Engn, Tehran, Iran
关键词
microwave life detection; Doppler frequency; ADS;
D O I
10.1109/ISSPIT.2006.270887
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The ability and how to use a microwave life-detection system to search for the humans buried under earthquake rubble or laid behind various barriers has been investigated. Based on the behavior of a human under multiple layers of barriers and the detection capability of the microwave tools a system has been proposed. This system operating at 1150 MHz can remotely defect the movement of the heart of the trapped alive people. The operation principle is based on detection of the Doppler frequency shift of the electromagnetic wave reflected from the periodic moving part of a living human body such as the heart. In this paper, various parts of a microwave life-detection system such as patch antenna, directional coupler, band-pass Microstrip filter, power amplifier, and low noise amplifier, are simulated using ADS2003A and Microwave Office software. The practical notes for realization of the system and of each part have been recommended. In addition, through using the simulated system, an overall systematic performance of a complete life detection system has been investigated.
引用
收藏
页码:685 / 690
页数:6
相关论文
共 50 条
  • [21] Deepfake source detection in a heart beat
    Umur Aybars Çiftçi
    İlke Demir
    Lijun Yin
    The Visual Computer, 2024, 40 : 2733 - 2750
  • [22] Multiple Frequency Detection System Design
    Liu, Wen
    Hu, Jun Da
    Shi, Ji Cui
    ADVANCES IN COMPUTER SCIENCE, ENVIRONMENT, ECOINFORMATICS, AND EDUCATION, PT I, 2011, 214 : 201 - 206
  • [23] Deepfake source detection in a heart beat
    Ciftci, Umur Aybars
    Demir, Ilke
    Yin, Lijun
    VISUAL COMPUTER, 2024, 40 (04): : 2733 - 2750
  • [24] Lab VIEW Based Design of Heart Disease Detection System
    Kaur, Poonam
    Sharma, R. K.
    2014 RECENT ADVANCES AND INNOVATIONS IN ENGINEERING (ICRAIE), 2014,
  • [25] A Simulation Design Based on the Six Quadrants Laser Detection System
    Zhang, Yan-mei
    Liu, Xu
    Xu, Fei
    Niu, Zhi-yin
    PROCEEDINGS OF THE 3RD INTERNATIONAL CONFERENCE ON ELECTRIC AND ELECTRONICS, 2013, : 141 - 144
  • [26] Space-Based Detection of Spoofing AIS Signals Using Doppler Frequency
    Guo, Shanzeng
    MULTISENSOR, MULTISOURCE INFORMATION FUSION: ARCHITECTURES, ALGORITHMS, AND APPLICATIONS 2014, 2014, 9121
  • [27] Systematic Design of an Optimum FMCW System for Medium to Long Range Detection with Constant Beat Frequency Technique
    Mokri, Mohammad Ali
    Masoumi, Nasser
    Tabrizi, Mohammad Moghaddam
    2015 23RD IRANIAN CONFERENCE ON ELECTRICAL ENGINEERING (ICEE), 2015, : 1406 - 1410
  • [28] An accurate heart beat detection method in the EKG recorded in fMRI system
    Oh, Sung Suk
    Chung, Jun-Young
    Yoon, Hyo Woon
    Park, HyunWook
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 656 - +
  • [29] Beat-to-beat heart rate detection by smartphone accelerometers
    Landreani, F.
    Martin-Yebra, A.
    Casellato, C.
    Frigo, C.
    Pavan, E.
    Migeotte, P. -F.
    Caiani, E. G.
    EUROPEAN HEART JOURNAL, 2016, 37 : 859 - 860
  • [30] Assessment of beat-to-beat heart rate detection method using a camera as contactless sensor
    Iozzia, L.
    Cerina, L.
    Mainardi, L. T.
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 521 - 524