Experimental Comparison of the Low-Frequency Noise of Small-Size Magnetic Sensors

被引:3
|
作者
Vyhnanek, Jan [1 ]
Ripka, Pavel [1 ]
机构
[1] Czech Tech Univ, Fac Elect Engn, Dept Measurement, Prague 16627, Czech Republic
关键词
Magnetic sensors; noise measurement; MAGNETOMETER; ARRAY;
D O I
10.1109/TMAG.2016.2633398
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Small-size ac magnetic-field sensors are used for nondestructive testing (NDT), magnetic particle detection, and other applications, which require high spatial resolution. Up to now, inductive coils dominated this area, as their sensitivity at kHz frequencies, is superior to other magnetic sensors. However, some applications, such as magnetic imaging through conducting sheath, require lower working frequencies, in extreme case units of Hz. We successfully replaced inductive coils by an AMR sensor in NDT application and for distance measurement. In this paper, we compare designs of miniature ac magnetic field sensors, their achievable frequency characteristics, dynamic range, and noise parameters.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] Experimental Study of Underwater Propeller Low-frequency Noise Flied
    Li Song
    Yang Desen
    Zhang Haoyang
    2016 IEEE/OES CHINA OCEAN ACOUSTICS SYMPOSIUM (COA), 2016,
  • [32] SMALL-SIZE VACUUM SENSORS BASED ON SILICON THERMOPHILES
    VANHERWAARDEN, AW
    VANDUYN, DC
    GROENEWEG, J
    SENSORS AND ACTUATORS A-PHYSICAL, 1991, 27 (1-3) : 565 - 569
  • [33] Low-frequency magnetic and resistance noise in magnetoresistive tunnel junctions
    Jiang, L
    Skovholt, JF
    Nowak, ER
    Slaughter, JM
    FLUCTUATIONS AND NOISE IN MATERIALS, 2004, : 13 - 27
  • [34] Low-frequency electrical noise in Ni: The effects of magnetic fluctuations
    Giordano, N
    PHYSICAL REVIEW B, 1996, 53 (22): : 14937 - 14940
  • [35] MONITORING AND ANALYSIS OF TECHNICAL LOW-FREQUENCY MAGNETIC NOISE IN KIEV
    Romenets, A. O.
    Orliuk, I. M.
    GEODYNAMICS, 2013, (15): : 314 - 316
  • [36] Reduction of low-frequency noise in magnetic induction tomography systems
    Scharfetter, H.
    Issa, S.
    4TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2009, 22 (1-3): : 752 - 755
  • [37] EXPERIMENTAL-STUDY OF EXCESS LOW-FREQUENCY NOISE IN TIN
    FLEETWOOD, DM
    GIORDANO, N
    PHYSICAL REVIEW B, 1982, 25 (02): : 1427 - 1430
  • [38] Design of a Preamplifier for Capacitive Sensors With Wide Low-Frequency Range and Low Drift Noise
    Nakamura, Tetsuo
    Kurihara, Yosuke
    Watanabe, Kajiro
    Terada, Masahide
    IEEE SENSORS JOURNAL, 2012, 12 (02) : 378 - 383
  • [39] Experimental study of a model of a small-size neutron generator with pulsed magnetic insulation
    K. I. Kozlovsky
    D. D. Ponomarev
    V. I. Ryzhkov
    A. S. Tsybin
    A. E. Shikanov
    Atomic Energy, 2012, 112 : 218 - 221
  • [40] Comparison of modeling approaches to low-frequency noise propagation in the ocean
    Korakas, Alexios
    Hovem, Jens Martin
    2013 MTS/IEEE OCEANS - BERGEN, 2013,