Determination of residues of endosulfan in human blood by a negative ion chemical ionization gas chromatographic/mass spectrometric method: impact of long-term aerial spray exposure

被引:6
|
作者
Ramesh, A [1 ]
Ravi, PE [1 ]
机构
[1] Int Inst Biotechnol & Toxicol, Dept Pesticide Chem, IIBAT, Madras 601301, Tamil Nadu, India
关键词
analysis; endosulfan; isomers; metabolites; blood; residues; environmental exposure;
D O I
10.1002/ps.628
中图分类号
S3 [农学(农艺学)];
学科分类号
0901 ;
摘要
A new and sensitive analytical method using negative ion chemical ionization gas chromatography/mass spectrometry in selective ion monitoring (SIM) mode has been developed for the determination of residues of endosulfan in the human blood. The residues of endosulfan are extracted from whole blood samples without separating the serum by the addition of 60% sulfuric acid at 10degreesC followed by partition with hexane+acetone (9+1 by volume). The total endosulfan is quantified as the sum of alpha-endosulfan, beta-endosulfan and endosulfan sulfate in SIM mode. The mass-fragment ions used for this purpose that are monitored for in SIM mode include endosulfan diol: 95, 169, 214, 313, alpha-endosulfan: 99, 242, 270, 406, beta-endosulfan: 99, 242, 270, 406, and endosulfan sulfate: 97, 353, 386. Recovery experiments were conducted at the concentration range 1.0-100 pg ml(-1). Results showed 112-98% recovery of total endosulfan from the whole blood samples. The relative standard deviation was 1.49-2.68%. The method was found to be highly sensitive in quantifying endosulfan residues down to the 0.1 pg ml(-1) level. Conversion of endosulfan to endosulfan diol was found to be less than 0.1% under the conditions used. The results were compared with published data. The applications of the analytical method for the determination of endosulfan residues in real samples was tested by analyzing 106 human blood samples collected from a population living in Padre village, Kasargode District, Kerala, India, where aerial spraying of endosulfan has been a common agricultural practice over the years. The results showed that none of the blood samples contained residues of endosulfan (alpha-endosulfan+beta-endosulfan+endosulfan sulfate) or endosulfan diol. The results were confirmed by the detection of the appropriate amounts in a number of these samples which had subsequently been spiked with endosulfan. (C) 2003 Society of Chemical Industry.
引用
收藏
页码:252 / 258
页数:7
相关论文
共 50 条
  • [21] Negative ion chemical ionization for the determination of methylphenidate in human plasma by stable isotope dilution gas chromatography/mass spectrometry
    Leis, HJ
    Fauler, G
    Raspotnig, G
    Windischhofer, W
    JOURNAL OF MASS SPECTROMETRY, 2000, 35 (09): : 1100 - 1104
  • [22] GAS-CHROMATOGRAPHIC MASS-SPECTROMETRIC DETERMINATION OF 4-HYDROXYLATED AND 6-HYDROXYLATED BILE-ACIDS IN HUMAN URINE WITH NEGATIVE-ION CHEMICAL IONIZATION DETECTION .254.
    GOTO, J
    HASEGAWA, K
    NAMBARA, T
    IIDA, T
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 574 (01): : 1 - 7
  • [23] Determination of polybrominated diphenyl ethers in human blood by gas chromatography-negative chemical ionization-mass spectrometry
    Qu Wei-Yue
    Bi Xin-Hui
    Sheng Guo-Ying
    Lu Shao-You
    Fu Jia-Mo
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2007, 35 (07) : 1015 - 1017
  • [24] GAS-CHROMATOGRAPHIC ELECTRON-IMPACT CHEMICAL-IONIZATION MASS-SPECTROMETRIC IDENTIFICATION OF CINMETACIN AND ITS METABOLITES IN HUMAN URINE
    MYUNG, SW
    KIM, MS
    YOON, CN
    PARK, JS
    AHN, WS
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 660 (01): : 75 - 84
  • [25] A sensitive and selective method for the determination of mevalonic acid in dog plasma by gas chromatography negative ion chemical ionization mass spectrometry
    Saisho, Y
    Kuroda, T
    Umeda, T
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1997, 15 (9-10) : 1223 - 1230
  • [26] Determination of alprazolam and alpha-hydroxyalprazolam in human plasma by gas chromatography negative-ion chemical ionization mass spectrometry
    Hold, KM
    Crouch, DJ
    Rollins, DE
    Wilkins, DG
    Canfield, DV
    Maes, RA
    JOURNAL OF MASS SPECTROMETRY, 1996, 31 (09): : 1033 - 1038
  • [27] DETERMINATION OF CORTISOL IN HUMAN PLASMA BY GAS-CHROMATOGRAPHY NEGATIVE-ION CHEMICAL-IONIZATION MASS-SPECTROMETRY
    HSU, FF
    WANG, LH
    BIER, DM
    ANALYTICAL BIOCHEMISTRY, 1994, 216 (02) : 401 - 405
  • [28] Stable isotope labelling and determination of ketoprofen in human plasma and urine by gas chromatography/negative ion chemical ionization mass spectrometry
    Leis, H.J.
    Leis, M.
    Windischhofer, W.
    Journal of Mass Spectrometry, 1996, 31 (05):
  • [29] Stable isotope labelling and determination of ketroprofen in human plasma and urine by gas chromatography negative ion chemical ionization mass spectrometry
    Leis, HJ
    Leis, M
    Windischhofer, W
    JOURNAL OF MASS SPECTROMETRY, 1996, 31 (05): : 486 - 492
  • [30] HIGHLY SENSITIVE GAS-CHROMATOGRAPHIC MASS-SPECTROMETRIC METHOD FOR THE DETERMINATION OF PLATELET-ACTIVATING FACTOR IN HUMAN-BLOOD
    YAMADA, K
    ASANO, O
    YOSHIMURA, T
    KATAYAMA, K
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 433 : 243 - 247