An overview of attenuation and scatter correction of planar and SPECT data for dosimetry studies

被引:22
|
作者
King, M [1 ]
Farncombe, T [1 ]
机构
[1] Univ Massachusetts, Sch Med, Div Nucl Med, Dept Radiol, Worcester, MA 01655 USA
关键词
SPECT; quantitation; dosimetry; attenuation correction; scatter correction;
D O I
10.1089/108497803765036346
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
A number of factors impact the accuracy of activity quantitation in planar and single photon emission computed tomographic (SPECT) imaging. Two important such factors are attenuation and scattering in the medium containing the activity. The first removes photons which otherwise would have been included in the images, and the second adds events to the images from photons which would not have otherwise been imaged. A number of methods have been developed to compensate for these biases to activity quantitation. This review will briefly introduce planar quantitation which is commonly used for dosimetric purposes, and then present a slightly more detailed overview of SPECT quantitation which is arguably more accurate. It will conclude by cautioning users of commercial. reconstruction software to validate it for quantitation before using it for dosimetric purposes.
引用
收藏
页码:181 / 190
页数:10
相关论文
共 50 条
  • [31] Quantitative Reconstruction of Multiplexed Multi-Pinhole SPECT with Scatter and Attenuation Correction
    Strydhorst, J.
    Wells, R. Glenn
    MEDICAL PHYSICS, 2011, 38 (06)
  • [32] CT-based attenuation and scatter correction compared with uniform attenuation correction in brain perfusion SPECT imaging for dementia
    Gillen, Rebecca
    Firbank, Michael J.
    Lloyd, Jim
    O'Brien, John T.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (17): : 6775 - 6787
  • [33] SCATTER AND ATTENUATION CORRECTION IN SPECT CARDIAC IMAGING - A COMPARISON USING MONTE-CARLO SIMULATED NONHOMOGENEOUS DATA
    LJUNGBERG, M
    KING, MA
    PAN, TS
    DEVRIES, DJ
    STRAND, SE
    JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (05) : P189 - P189
  • [34] Simultaneous 3D correction for attenuation, scatter, and detector response in SPECT
    Laurette, I
    Zeng, GL
    Gullberg, GT
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 1220 - 1223
  • [35] Novel attenuation correction of SPECT images using scatter photopeak window data for the detection of coronary artery disease
    Yamauchi, Yohei
    Kanzaki, Yumiko
    Otsuka, Kaoru
    Hayashi, Masuo
    Okada, Mami
    Nogi, Shimpei
    Morita, Hideaki
    Komori, Tsuyoshi
    Ishizaka, Nobukazu
    JOURNAL OF NUCLEAR CARDIOLOGY, 2014, 21 (01) : 109 - 117
  • [36] Novel attenuation correction of SPECT images using scatter photopeak window data for the detection of coronary artery disease
    Yohei Yamauchi
    Yumiko Kanzaki
    Kaoru Otsuka
    Masuo Hayashi
    Mami Okada
    Shimpei Nogi
    Hideaki Morita
    Tsuyoshi Komori
    Nobukazu Ishizaka
    Journal of Nuclear Cardiology, 2014, 21 : 109 - 117
  • [37] Optimization of becquerel calibration factor for quantitative bone SPECT without attenuation and scatter correction in the lumbar spine: Head-to-head comparison with attenuation and scatter correction
    Ichikawa, H.
    Onoguchi, M.
    Shibutani, T.
    Ito, T.
    Shimada, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (SUPPL 1) : S504 - S504
  • [38] Simulation and patient studies of scatter correction in cardiac SPECT imaging
    Noori-Asl M.
    Bitarafan-Rajabi A.
    Iranian Journal of Medical Physics, 2019, 16 (06) : 430 - 438
  • [39] Towards Quantitative SPECT: Error Estimation of SPECT OSEM with 3D Resolution Recovery, Attenuation Correction and Scatter Correction
    Zeintl, J.
    Vija, A. H.
    Yahil, A.
    Ding, X.
    Hornegger, J.
    Kuwert, T.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3381 - +
  • [40] AN EMISSION-BASED TECHNIQUE FOR OBTAINING ATTENUATION CORRECTION DATA FOR MYOCARDIAL SPECT STUDIES
    MADSEN, MT
    KIRCHNER, PT
    EDLIN, JP
    NATHAN, MA
    KAHN, D
    NUCLEAR MEDICINE COMMUNICATIONS, 1993, 14 (08) : 689 - 695