Space-based correction method for LED array misalignment in Fourier ptychographic microscopy

被引:8
|
作者
Zhu, Youqiang [1 ]
Sun, Minglu [1 ,2 ]
Wu, Peilin [1 ,2 ]
Mu, Quanquan [1 ,2 ]
Xuan, Li [1 ,2 ]
Li, Dayu [1 ]
Wang, Bin [1 ,2 ]
机构
[1] Chinese Acad Sci, Changchun Inst Opt Fine Mech & Phys, Changchun 130033, Peoples R China
[2] Univ Chinese Acad Sci, Ctr Mat Sci & Optoelect Engn, Beijing 100049, Peoples R China
基金
国家重点研发计划; 中国国家自然科学基金;
关键词
Computational imaging; Fourier ptychographic microscopy; Misalignment; Particle swarm optimization; SHOT PHASE RETRIEVAL; HIGH-RESOLUTION; WIDE-FIELD; RECONSTRUCTION; ILLUMINATION;
D O I
10.1016/j.optcom.2022.128163
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Fourier ptychographic microscopy is a super-resolution technique, which could break through the Space-Band Product (SBP) limit of the system by employing varied-illumination and phase retrieval algorithm. A LED array is used to provide angularly varying illuminations, which is portable and cheap. However, the installation accuracy of the LED array is not sufficient, resulting in position misalignment errors. The misalignment errors not only cause the calculation error of the sub-apertures in the frequency domain, but also the artifacts in reconstruction images. Although some correction methods have been proposed, the correction ability of these methods cannot deal with the misalignment errors well. In this paper, we proposed a misalignment errors correction method. This method uses the Particle swarm optimization (PSO) algorithm to search the four misalignment parameters (delta x, delta y, theta, delta h) in space domain. It is termed as Space based correction (SBC) method. Compared with the state-of-art methods, the SBC method is more stable and accuracy.& nbsp;
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Accurate and stable two-step LED position calibration method for Fourier ptychographic microscopy
    Wei, Haojie
    Du, Jing
    Liu, Lei
    He, Yu
    Yang, Yong
    Hu, Song
    Tang, Yan
    JOURNAL OF BIOMEDICAL OPTICS, 2021, 26 (10)
  • [32] Sampling criteria for Fourier ptychographic microscopy in object space and frequency space
    Sun, Jiasong
    Chen, Qian
    Zhang, Yuzhen
    Zuo, Chao
    OPTICS EXPRESS, 2016, 24 (14): : 15765 - 15781
  • [33] Precise and independent position correction strategy for Fourier ptychographic microscopy
    Chen, Yiwen
    Xu, Tingfa
    Zhang, Jizhou
    Zhang, Jinhua
    Li, Jianan
    OPTIK, 2022, 265
  • [34] Hyperuniform illumination subsampling method for Fourier ptychographic microscopy
    Ni, Ying-Hui
    Fan, Si -Yuan
    Zhang, Shu-Yuan
    Sun, Ming-Jie
    OPTICS AND LASERS IN ENGINEERING, 2024, 176
  • [35] A fast Fourier ptychographic microscopy method with biomedical application
    Duan, Chaijie
    Kuang, Yawei
    Ma, Hui
    QUANTITATIVE PHASE IMAGING III, 2017, 10074
  • [36] Linear-space-variant model for Fourier ptychographic microscopy
    Feng, Tianci
    Wang, Aiye
    Wang, Zhiping
    Liao, Yizheng
    Pan, An
    OPTICS LETTERS, 2024, 49 (10) : 2617 - 2620
  • [37] Fourier Ptychographic Microscopy Reconstruction Method Based on Residual Local Mixture Network
    Wang, Yan
    Wang, Yongshan
    Li, Jie
    Wang, Xiaoli
    SENSORS, 2024, 24 (13)
  • [38] Research on Blood Cell Image Detection Method Based on Fourier Ptychographic Microscopy
    Li, Mingjing
    Yang, Le
    Fang, Shu
    Liu, Xinyang
    Yun, Haijiao
    Wang, Xiaoli
    Du, Qingyu
    Han, Ziqing
    Wang, Junshuai
    SENSORS, 2025, 25 (03)
  • [39] An Efficient Fourier Ptychographic Microscopy Imaging Method Based on Angle Illumination Optimization
    Li Tong
    Zhao Jufeng
    Mao Haifeng
    Cui Guangmang
    Hu Jinxing
    LASER & OPTOELECTRONICS PROGRESS, 2020, 57 (08)
  • [40] Blind deep-learning based preprocessing method for Fourier ptychographic microscopy
    Wu, Kai
    Pan, An
    Sun, Zhonghan
    Shi, Yinxia
    Gao, Wei
    OPTICS AND LASER TECHNOLOGY, 2024, 169