Arthroscopic Fixation Technique for Comminuted, Displaced Greater Tuberosity Fracture

被引:49
|
作者
Ji, Jong-Hun [1 ]
Shafi, Mohamed [1 ]
Song, In-Soo [2 ]
Kim, Young-Yul [1 ]
McFarland, Edward G. [3 ]
Moon, Chang-Yun [1 ]
机构
[1] Catholic Univ Korea, Daejon St Marys Hosp, Dept Orthoped Surg, Coll Med, Taejon 302803, South Korea
[2] Sun Hosp, Taejon, South Korea
[3] Johns Hopkins Univ, Baltimore, MD USA
关键词
SUTURE-ANCHOR FIXATION; ROTATOR CUFF REPAIR; SINGLE-ROW; INTERNAL-FIXATION; PROXIMAL HUMERUS; REDUCTION; EPIDEMIOLOGY; FOOTPRINT; PRESSURE; SHOULDER;
D O I
10.1016/j.arthro.2009.09.011
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The purpose of this retrospective study was to evaluate the early results of arthroscopic treatment in patients with comminuted, displaced greater tuberosity (GT) fractures using the arthroscopic double-row suture anchor fixation (ADSF) technique. Methods: Between August 2004 and December 2007, we used the ADSF technique in 16 cases of isolated comminuted, displaced GT fractures. The early clinical results were evaluated in these patients at a mean of 24 months (range, 16 to 51 months) after surgery. There were 11 male and 5 female patients with a mean age of 56.5 years (range, 27 to 82 years). These 16 cases had at least 5 mm of displacement of the fracture fragments in any plane. For measurement of clinical outcomes, we assessed range of motion and evaluated the visual analog scale score; the University of California, Los Angeles (UCLA) rating scale; and the shoulder index of the American Shoulder and Elbow Surgeons. Results: At final follow-up, the visual analog scale score improved from 9.4 (range, 8 to 10 points) to 1.2 (range, 0 to 4 points), the mean UCLA score improved to 31 points (range, 21 to 35 points) postoperatively, and the American Shoulder and Elbow Surgeons score improved to 88.1 points (range, 81.5 to 100 points). According to the UCLA score, there were 3 excellent results, 11 good results, and 2 poor results. Mean forward flexion was 148.7 degrees (range, 120 degrees to 170 degrees), mean abduction was 145 degrees (range, 120 degrees to 170 degrees), mean external rotation in the neutral position was 24 degrees (range, 10 degrees to 40 degrees), and internal rotation improved to the first lumbar vertebral level (from L3 to T7) at last follow-up. Conclusions: The early results of the ADSF technique used for displaced, comminuted GT fractures are encouraging, and arthroscopists should attempt to expand the indications for arthroscopic treatment of these fractures. Level of Evidence: Level IV, therapeutic case series.
引用
收藏
页码:600 / 609
页数:10
相关论文
共 50 条
  • [31] Arthroscopic fixation for a malunited greater tuberosity fracture using the suture-bridge technique: technical report and literature review
    Jong-Hun Ji
    Chang-Yun Moon
    Young-Yul Kim
    Mohamed Shafi
    Knee Surgery, Sports Traumatology, Arthroscopy, 2009, 17 : 1473 - 1476
  • [32] The bony partial articular surface tendon avulsion lesion: An arthroscopic technique for fixation of the partially avulsed greater tuberosity fracture
    Bhatia, Deepak N.
    de Beer, Joe F.
    van Rooyen, Karin S.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2007, 23 (07): : 786.e1 - 786.e6
  • [33] Arthroscopic reduction and fixation for isolated greater tuberosity fractures
    Wang Yong-ping
    Zhao Jin-zhong
    Huangfu Xiao-qiao
    Liu Wen-xin
    Jiang Yao
    Zhou Xin-hua
    He Yao-hua
    CHINESE MEDICAL JOURNAL, 2012, 125 (07) : 1272 - 1275
  • [34] Arthroscopic reduction and internal fixation of a displaced fracture of the acromion: case report and arthroscopic technique
    Hsu, Jason E.
    Lee, Chang Soo
    CURRENT ORTHOPAEDIC PRACTICE, 2011, 22 (06): : 564 - 566
  • [35] A new low-profile anatomic locking plate for fixation of comminuted, displaced greater tuberosity fractures of the proximal humerus
    Zeng, Lang-Qing
    Chen, Yun-Feng
    Jiang, Yu-Wen
    Zeng, Lu-Lu
    Miao, Xiao-Gang
    Liang, Wei-Guo
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2021, 30 (06) : 1402 - 1409
  • [36] Comparison between arthroscopic suture anchor fixation and open plate fixation in the greater tuberosity fracture of the proximal humerus
    Kim, Young-Jun
    Ji, Jong-Hun
    Park, Sang-Eun
    Parikh, Darshil
    Lee, Woo-Jin
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2024, 34 (01): : 621 - 631
  • [37] Comparison between arthroscopic suture anchor fixation and open plate fixation in the greater tuberosity fracture of the proximal humerus
    Young-Jun Kim
    Jong-Hun Ji
    Sang-Eun Park
    Darshil Parikh
    Woo-Jin Lee
    European Journal of Orthopaedic Surgery & Traumatology, 2024, 34 (1) : 621 - 631
  • [38] Arthroscopic management of occult greater tuberosity fracture of the shoulder
    Park S.-E.
    Ji J.-H.
    Shafi M.
    Jung J.J.
    Gil H.-J.
    Lee H.-H.
    European Journal of Orthopaedic Surgery & Traumatology, 2014, 24 (4) : 475 - 482
  • [39] Chronic displaced greater tuberosity fracture of the proximal humerus - Diagnosis
    Butler, JS
    Smith, AM
    Sundaram, M
    Sperling, JW
    ORTHOPEDICS, 2004, 27 (10) : 1016 - +
  • [40] Arthroscopic treatment for greater tuberosity fractures: Rationale and surgical technique
    Taverna, E
    Sansone, V
    Battistella, F
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2004, 20 (06): : e53 - e57