Usefulness of 3D-PISA as compared to guideline endorsed parameters for mitral regurgitation quantification

被引:19
|
作者
Schmidt, Frank P. [1 ]
Gniewosz, Theresa [1 ]
Jabs, Alexander [1 ]
Muenzel, Thomas [1 ]
Hink, Ulrich [1 ]
Lancellotti, Patrizio [2 ]
von Bardeleben, Ralph-Stephan [1 ]
机构
[1] Johannes Gutenberg Univ Mainz, Dept Med 2, Univ Med Ctr, D-55131 Mainz, Germany
[2] Univ Liege Hosp, GIGA Cardiovasc Sci, Heart Valve Clin, CHU Sart Tilman, Liege, Belgium
来源
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING | 2014年 / 30卷 / 08期
关键词
Mitral regurgitation; 3D echocardiography; 3D PISA; ISOVELOCITY SURFACE-AREA; COLOR DOPPLER-ECHOCARDIOGRAPHY; FLOW CONVERGENCE METHOD; VENA CONTRACTA AREA; ORIFICE AREA; IN-VITRO; RECOMMENDATIONS; VALIDATION; ASSOCIATION; SEVERITY;
D O I
10.1007/s10554-014-0496-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study was intended to evaluate the diagnostic value of three dimensional proximal isovelocity surface area (3D PISA) derived effective regurgitant orifice area (EROA) and the accuracy of automatic 3D PISA detection in a population resembling clinical practice. Quantification of mitral regurgitation (MR) remains challenging and 3D PISA EROA is a novel diagnostic tool with promising results. However its' usefulness compared to guideline endorsed parameters has not been shown. In 93 consecutive patients examined in routine practice conventional parameters and 3D-datasets for offline 3D PISA evaluation were recorded. EROA was determined from the largest (peak) PISA and also averaged over systole for meanEROA. Results of 3D PISA calculation were compared with a combination of expert grading by two examiners and two scores for MR grading. In receiver operator characteristic-analysis the meanEROA as determined by 3D PISA had the best diagnostic value (AUC = 0.907 CI 0.832-0.983) as compared to peakEROA (AUC 0.840 CI 0.739-0.941), vena contracta width (AUC 0.831 CI 0.745-0.918) and 2D PISA (AUC 0.747 CI 0.644-0.850). A meanEROA of 0.15 cm(2) had a sensitivity of 88.2 % and a specificity of 81.4 % for distinguishing severe from non-severe MR. Semiautomatic 3D PISA detection correlated very well with manually corrected values (r = 0.955). Semiautomatic 3D PISA measurement is feasible in a clinical population and has better diagnostic value compared to 2D PISA. Calculation of mean EROA throughout systole further improves diagnostic value compared to conventional parameters.
引用
收藏
页码:1501 / 1508
页数:8
相关论文
共 50 条
  • [21] Quantification of mitral valve regurgitation volume by 2D and 3D echocardiography compared with cardiac magnetic resonance: a systematic review and meta-analysis
    Skoldborg, V.
    Abdulla, J.
    EUROPEAN HEART JOURNAL, 2019, 40 : 1996 - 1996
  • [22] Quantification of valve dimensions by transesophageal 3D echocardiography in patients with functional and degenerative mitral regurgitation
    Goebel, B.
    Heck, R.
    Hamadanchi, A.
    Otto, S.
    Jung, C.
    Lauten, A.
    Figulla, H. R.
    Poerner, T. C.
    EUROPEAN HEART JOURNAL, 2015, 36 : 426 - 426
  • [23] 3D VENA CONTRACTA AREA FOR THE QUANTIFICATION OF RESIDUAL MITRAL REGURGITATION AFTER MITRACLIP PROCEDURE
    Avenatti, Eleonora
    Reisman, Mark
    Barker, Colin
    Mackensen, G. Burkhard
    Little, Stephen
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (11) : 1254 - 1254
  • [24] Quantification of Mitral Regurgitation on Cardiac Computed Tomography: Comparison With Qualitative and Quantitative Echocardiographic Parameters
    Arnous, Samer
    Killeen, Ronan P.
    Martos, Ramon
    Quinn, Martin
    McDonald, Kenneth
    Dodd, Jonathan Dermot
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2011, 35 (05) : 625 - 630
  • [25] Impact of correcting the 2D PISA method on the quantification of functional tricuspid regurgitation severity
    Tomaselli, Michele
    Badano, Luigi P.
    Mene, Roberto
    Gavazzoni, Mara
    Heilbron, Francesca
    Radu, Noela
    Caravita, Sergio
    Baratto, Claudia
    Oliverio, Giorgio
    Florescu, Diana R.
    Parati, Gianfranco
    Muraru, Denisa
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2022, 23 (11) : 1459 - 1470
  • [26] Mitral valve regurgitation and 3D echocardiography
    Zakkar, Mustafa
    Patni, Ravi
    Punjabi, Prakash P.
    FUTURE CARDIOLOGY, 2010, 6 (02) : 231 - 242
  • [27] Quantification of mitral regurgitation during percutaneous mitral valve repair: added value of simultaneous hemodynamic and 3D echocardiographic assessment
    Ilonka Rohm
    Tudor C. Poerner
    Ali Hamadanchi
    Sylvia Otto
    Torsten Doenst
    Christian Jung
    P. Christian Schulze
    Björn Goebel
    The International Journal of Cardiovascular Imaging, 2017, 33 : 1531 - 1539
  • [28] Quantification of mitral regurgitation during percutaneous mitral valve repair: added value of simultaneous hemodynamic and 3D echocardiographic assessment
    Rohm, Ilonka
    Poerner, Tudor C.
    Hamadanchi, Ali
    Otto, Sylvia
    Doenst, Torsten
    Jung, Christian
    Schulze, P. Christian
    Goebel, Bjorn
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2017, 33 (10): : 1531 - 1539
  • [29] QUANTIFICATION OF MITRAL REGURGITATION - COMPARISON OF 3 COLOR-DOPPLER ECHOCARDIOGRAPHIC METHODS
    GROSSMANN, G
    GIESLER, M
    SCHMIDT, A
    KOCHS, M
    WIESHAMMER, S
    FELDER, C
    HOHER, M
    HOMBACH, V
    ZEITSCHRIFT FUR KARDIOLOGIE, 1995, 84 (03): : 190 - 197
  • [30] Quantification of mitral regurgitation orifice area by 3-dimensional echocardiography: comparison with effective regurgitant orifice area by PISA method and proximal regurgitant jet diameter
    Lange, A
    Palka, P
    Donnelly, JE
    Burstow, DJ
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2002, 86 (01) : 87 - 98