Usefulness of 3D-PISA as compared to guideline endorsed parameters for mitral regurgitation quantification

被引:19
|
作者
Schmidt, Frank P. [1 ]
Gniewosz, Theresa [1 ]
Jabs, Alexander [1 ]
Muenzel, Thomas [1 ]
Hink, Ulrich [1 ]
Lancellotti, Patrizio [2 ]
von Bardeleben, Ralph-Stephan [1 ]
机构
[1] Johannes Gutenberg Univ Mainz, Dept Med 2, Univ Med Ctr, D-55131 Mainz, Germany
[2] Univ Liege Hosp, GIGA Cardiovasc Sci, Heart Valve Clin, CHU Sart Tilman, Liege, Belgium
来源
关键词
Mitral regurgitation; 3D echocardiography; 3D PISA; ISOVELOCITY SURFACE-AREA; COLOR DOPPLER-ECHOCARDIOGRAPHY; FLOW CONVERGENCE METHOD; VENA CONTRACTA AREA; ORIFICE AREA; IN-VITRO; RECOMMENDATIONS; VALIDATION; ASSOCIATION; SEVERITY;
D O I
10.1007/s10554-014-0496-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study was intended to evaluate the diagnostic value of three dimensional proximal isovelocity surface area (3D PISA) derived effective regurgitant orifice area (EROA) and the accuracy of automatic 3D PISA detection in a population resembling clinical practice. Quantification of mitral regurgitation (MR) remains challenging and 3D PISA EROA is a novel diagnostic tool with promising results. However its' usefulness compared to guideline endorsed parameters has not been shown. In 93 consecutive patients examined in routine practice conventional parameters and 3D-datasets for offline 3D PISA evaluation were recorded. EROA was determined from the largest (peak) PISA and also averaged over systole for meanEROA. Results of 3D PISA calculation were compared with a combination of expert grading by two examiners and two scores for MR grading. In receiver operator characteristic-analysis the meanEROA as determined by 3D PISA had the best diagnostic value (AUC = 0.907 CI 0.832-0.983) as compared to peakEROA (AUC 0.840 CI 0.739-0.941), vena contracta width (AUC 0.831 CI 0.745-0.918) and 2D PISA (AUC 0.747 CI 0.644-0.850). A meanEROA of 0.15 cm(2) had a sensitivity of 88.2 % and a specificity of 81.4 % for distinguishing severe from non-severe MR. Semiautomatic 3D PISA detection correlated very well with manually corrected values (r = 0.955). Semiautomatic 3D PISA measurement is feasible in a clinical population and has better diagnostic value compared to 2D PISA. Calculation of mean EROA throughout systole further improves diagnostic value compared to conventional parameters.
引用
收藏
页码:1501 / 1508
页数:8
相关论文
共 50 条
  • [1] Usefulness of 3D-PISA as compared to guideline endorsed parameters for mitral regurgitation quantification
    Frank P. Schmidt
    Theresa Gniewosz
    Alexander Jabs
    Thomas Münzel
    Ulrich Hink
    Patrizio Lancellotti
    Ralph-Stephan von Bardeleben
    The International Journal of Cardiovascular Imaging, 2014, 30 : 1501 - 1508
  • [2] Real-time 3D echocardiography: impact on quantification of mitral regurgitation by PISA method
    Necas, J.
    Kovalova, S.
    Vespalec, J.
    EUROPEAN HEART JOURNAL, 2007, 28 : 395 - 395
  • [3] Quantification of mitral regurgitation by calculation of regurgitant volume: 3D left ventricular echocardiography versus PISA
    Arsac, F.
    Floris, N.
    Reant, P.
    Dijos, M.
    Roudaut, R.
    Lafitte, S.
    EUROPEAN HEART JOURNAL, 2012, 33 : 101 - 101
  • [4] CMR quantification of mitral regurgitation is more reliable than PISA
    Militaru, S.
    Hami, K.
    Houard, L.
    Pasquet, A.
    Vancraeynest, D.
    Pouleur, A. C.
    Vanoverschelde, J. L.
    Gerber, B. L.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2019, 20 : 407 - 407
  • [5] Regurgitation Quantification Using 3D PISA in Volume Echocardiography
    Grady, Leo
    Datta, Saurabh
    Kutter, Oliver
    Duong, Christophe
    Wein, Wolfgang
    Little, Stephen H.
    Igo, Stephen R.
    Liu, Shizhen
    Vanna, Mani
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION, MICCAI 2011, PT III, 2011, 6893 : 512 - +
  • [6] 3D Echocardiographic Quantification in Functional Mitral Regurgitation
    Lang, Roberto M.
    Adams, David H.
    JACC-CARDIOVASCULAR IMAGING, 2012, 5 (04) : 346 - 347
  • [7] Automated Quantification of Mitral Regurgitation by 3D PISA Using Real Time Three Dimensional Volume Echocardiography: Comparisons with 2D PISA and Magnetic Resonance Imaging
    Heo, Ran
    Chang, Hyuk-Jae
    Lee, Jin-Kyung
    Song, Ran-Young
    Jung, Hee-Jung
    Kim, Young-Jin
    Shim, Chi Young
    Datta, Saurabh
    Hong, Geu-Ru
    Ha, Jong-Won
    Chung, Namsik
    CIRCULATION, 2012, 126 (21)
  • [8] MITRAL REGURGITATION - USEFULNESS OF HEMODYNAMIC PARAMETERS TO PREDICT OPERATIVE RISK
    CARLON, R
    BRUNI, A
    MEDICINA-RIVISTA DELLA ENCICLOPEDIA MEDICA ITALIANA, 1984, 4 (01): : 80 - 82
  • [9] Assessment of the PISA shape by 3D echocardiography in children with mitral regurgitation or ventricular shunt
    Ziani, A.
    Latcu, D.
    Abadir, S.
    Acar, P.
    EUROPEAN HEART JOURNAL, 2008, 29 : 873 - 873
  • [10] Quantification of Tethering Patterns in Secondary Mitral Regurgitation by 3D Echocardiography Mitral Valve Mapping
    Capoulade, Romain
    Mihos, Christos G.
    Handschumacher, Mark D.
    Teoh, Jonathan G.
    Zeng, Xin
    Park, Yong H.
    Bartko, Philipp E.
    D'Alessandro, David A.
    Melnitchouk, Serguei
    Levine, Robert A.
    Hung, Judy W.
    CIRCULATION, 2016, 134