Effect of an ionic air cleaner on indoor/outdoor particle ratios in a residential environment

被引:21
|
作者
Berry, David
Mainelis, Gediminas
Fennell, Donna
机构
[1] Rutgers State Univ, Dept Environm Sci, New Brunswick, NJ 08901 USA
[2] Univ Michigan, Dept Civil & Environm Engn, Ann Arbor, MI 48109 USA
关键词
D O I
10.1080/02786820701199702
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
We tested a leading commercially available ionic air cleaner in a typical residential apartment to study the effect of the device on indoor/outdoor airborne particle number and mass concentration ratios. In addition, we also determined the indoor ozone and ion concentration levels. When measured during normal daily activity, the average indoor/outdoor mass concentration ratio was reduced from 1.03 to 0.73 and the number concentration ratios underwent reductions for most of the particle size fractions. However, due to a substantial inter- and intra-measurement variation in particle ratios, the observed average reductions were not statistically significant. When measurements were performed in a still room, the indoor/outdoor particle mass concentration ratio decreased from 0.9-1.4 to 0.3-0.4 in eight hours when the air cleaner was operating. Ambient ozone concentrations measured in the middle of the apartment were between 13-19 ppb during normal daily activity and the ozone levels increased to 77 ppb when measured in front of the ionic cleaner during still conditions. We also found that that there was a limited vertical diffusion of ions. The highest ion concentrations were measured at a 0.5 m height from the floor and decreased substantially with increasing measurement height. This finding may have implications for effective particle removal from a person's breathing zone. Overall, we found that the tested brand of commercially available ionic air cleaners may have the capability to remove some airborne particulate matter in actual residential settings, but its cleaning effect is reduced under normal daily activity.
引用
收藏
页码:315 / 328
页数:14
相关论文
共 50 条
  • [41] Evaluation of urban residential thermal comfort in relation to indoor and outdoor air temperatures in Ibadan, Nigeria
    Adunola, Adewale Oluseyi
    [J]. BUILDING AND ENVIRONMENT, 2014, 75 : 190 - 205
  • [42] The lasting effect of limonene-induced particle formation on air quality in a genuine indoor environment
    Roesch, Carolin
    Wissenbach, Dirk K.
    von Bergen, Martin
    Franck, Ulrich
    Wendisch, Manfred
    Schlink, Uwe
    [J]. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2015, 22 (18) : 14209 - 14219
  • [43] Evaluation of particle penetration factors based on indoor PM2.5 removal by an air cleaner
    Chaohua Peng
    Peiyong Ni
    Guannan Xi
    Weiguang Tian
    Lujian Fan
    Dacheng Zhou
    Qi Zhang
    Yu Tang
    [J]. Environmental Science and Pollution Research, 2020, 27 : 8395 - 8405
  • [44] The effect of an ion generator on indoor air quality in a residential room
    Waring, M. S.
    Siegel, J. A.
    [J]. INDOOR AIR, 2011, 21 (04) : 267 - 276
  • [45] Effect of Window Characteristics on Indoor Air Quality in Residential Housing
    Li, Xianli
    You, Shijun
    Xia, Ying
    [J]. 2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 3695 - +
  • [46] Evaluation of particle penetration factors based on indoor PM2.5 removal by an air cleaner
    Peng, Chaohua
    Ni, Peiyong
    Xi, Guannan
    Tian, Weiguang
    Fan, Lujian
    Zhou, Dacheng
    Zhang, Qi
    Tang, Yu
    [J]. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2020, 27 (08) : 8395 - 8405
  • [47] EFFECT OF AN ELECTRONIC AIR CLEANER AND NEGATIVE IONIZER ON THE POPULATION OF INDOOR MOLD SPORES
    MALONEY, MJ
    WRAY, BB
    DURANT, RH
    SMITH, L
    SMITH, L
    [J]. ANNALS OF ALLERGY, 1987, 59 (03): : 192 - 194
  • [48] EFFECT OF AN ELECTRONIC AIR CLEANER AND NEGATIVE IONIZER ON THE POPULATION OF INDOOR MOLD SPORES
    MALONEY, MJ
    WRAY, BB
    SMITH, L
    [J]. ANNALS OF ALLERGY, 1985, 54 (04): : 352 - 352
  • [49] Indoor and outdoor air quality assessment in daycare centres in Ghent (Belgium) in view of outdoor sleeping in an urban environment
    De Coster, Gynaika
    Van Overmeiren, Preben
    Vandermeersch, Lore
    Van Langenhove, Herman
    Demeestere, Kristof
    Walgraeve, Christophe
    [J]. ATMOSPHERIC ENVIRONMENT, 2023, 303
  • [50] CHARACTERIZATION OF FINE PARTICLE AEROSOLS IN INDOOR AND OUTDOOR AIR IN TELECOMMUNICATION EXCHANGE BUILDINGS.
    Raunemaa, T.
    Hautojarvi, A.
    Lindfors, V.
    Reponen, A.
    [J]. Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms, 1983, 231 (B3) (1-3) : 489 - 492