Leakage current in high-purity germanium detectors with amorphous semiconductor contacts

被引:15
|
作者
Looker, Q. [1 ,2 ]
Amman, M. [1 ]
Vetter, K. [1 ,2 ]
机构
[1] Univ Calif Berkeley, Ernest Orlando Lawrence Berkeley Natl Lab, Berkeley, CA 94720 USA
[2] Univ Calif Berkeley, Dept Nucl Engn, Berkeley, CA 94720 USA
关键词
Gamma-ray detectors; High-parity germanium; Radiation detectors; Semiconductor radiation detectors; STRIP DETECTORS; SILICON; FABRICATION; OPERATION; BARRIER; LAYER;
D O I
10.1016/j.nima.2014.12.104
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Amorphous semiconductor electrical contacts on high purity Ge radiation detectors have become a valuable technology because they are simple to fabricate, result in thin dead layers, block both electron and hole injection, and can readily be finely segmented as needed for applications requiring imaging or particle tracking. Though significant numbers of detectors have been successfully produced for a variety of applications using the amorphous semiconductor contact technology, there remains a need to better understand the dependence of performance characteristics, particularly leakage current, on the fabrication process parameters so that the performance can be better optimized. To this end, we have performed a systematic study of leakage current on BF-sputter-deposited amorphous-Ge (a-Ge) and amorphous-Si (a-Si) contacts as a function of process and operational parameters including sputter gas pressure and composition, number of detector temperature cycles, and time spent at room temperature. The study focused primarily on the current resulting from electron injection at the contact. Significant findings from the study include that a-Si produces lower electron injection than a-Ge, the time the detector spends at room temperature rather than the number of temperature cycles experienced by the detector is the primary factor associated with leakage current change when the detector is warmed, and the time stability of the a-Ge contact depends on the sputter gas pressure with a higher pressure producing more stable characteristics. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:138 / 147
页数:10
相关论文
共 50 条
  • [31] RESPONSE OF HIGH-PURITY GERMANIUM DETECTORS TO CHARGED-PARTICLES
    BACHER, AD
    SLOAN, WT
    KOVAR, DG
    PEHL, RH
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1974, 19 (04): : 529 - 529
  • [32] PHOTOMASK TECHNIQUE FOR FABRICATING HIGH-PURITY GERMANIUM STRIP DETECTORS
    GUTKNECHT, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 288 (01): : 13 - 18
  • [33] EFFECT OF DISLOCATION OF ENERGY RESOLUTION OF HIGH-PURITY GERMANIUM DETECTORS
    GLASOW, PA
    HALLER, EE
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1976, 23 (01) : 92 - 96
  • [34] TEMPERATURE SENSITIVITY OF SURFACE CHANNEL EFFECTS ON HIGH-PURITY GERMANIUM DETECTORS
    HULL, EL
    PEHL, RH
    MADDEN, NW
    LUKE, PN
    CORK, CP
    MALONE, DL
    XING, JS
    KOMISARCIK, K
    VANDERWERP, JD
    FRIESEL, DL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 364 (03): : 488 - 495
  • [35] Advancing Nuclear Breast Imaging with the use of High-Purity Germanium Detectors
    Campbell, Desmond L.
    Peterson, Todd E.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3025 - 3028
  • [36] Uncertainty of Plutonium Isotopic Measurements with Microcalorimeter and High-Purity Germanium Detectors
    Hoover, Andrew S.
    Winkler, Ryan
    Rabin, Michael W.
    Bennett, Douglas A.
    Doriese, William B.
    Fowler, Joseph W.
    Hayes-Wehle, James
    Horansky, Robert D.
    Reintsema, Carl D.
    Schmidt, Dan R.
    Vale, Leila R.
    Ullom, Joel N.
    Schaffer, Kathryn
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2014, 61 (04) : 2365 - 2372
  • [37] THE USE OF HIGH-PURITY GERMANIUM DETECTORS FOR X-RAY-MICROANALYSIS
    LOCK, DA
    INSTITUTE OF PHYSICS CONFERENCE SERIES, 1993, (130): : 173 - 176
  • [38] INCREASING RELIABILITY OF FABRICATION AND HANDLING OF LARGE HIGH-PURITY GERMANIUM DETECTORS
    EWINS, J
    LLACER, J
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1974, NS21 (01) : 370 - 373
  • [39] High-purity germanium strip detectors - Possible applications to SR studies
    Beveridge, TE
    Gillam, JE
    Lewis, RA
    Berry, A
    Hall, CJ
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 4672 - 4675
  • [40] HIGH-PURITY PLANAR GERMANIUM DETECTORS FOR INVIVO MEASUREMENTS OF TRANSURANIC NUCLIDES
    PALMER, HE
    RIEKSTS, GA
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1984, 46 : 314 - 316