Thermal performance of a closed wet cooling tower for chilled ceilings: measurement and CFD simulation

被引:0
|
作者
Riffat, S [1 ]
Oliveira, A [1 ]
Facao, J [1 ]
Gan, GH [1 ]
Doherty, P [1 ]
机构
[1] Univ Nottingham, Sch Built Environm, Inst Bldg Technol, Nottingham NG7 2RD, England
关键词
cooling tower; chilled ceiling; thermal performance; CFD;
D O I
10.1002/1099-114X(20001025)24:13<1171::AID-ER668>3.0.CO;2-3
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A closed wet cooling tower, adapted for use with chilled ceilings in buildings, was tested experimentally. The thermal efficiency of the cooling tower was measured for different air flow rates, water flow rates, spray flow rates and wet bulb air temperatures. CFD was also used to predict the thermal performance of the cooling tower. Good agreement was obtained between CFD prediction and experimental measurement. Copyright (C) 2000 John Wiley & Sons, Ltd.
引用
收藏
页码:1171 / 1179
页数:9
相关论文
共 50 条
  • [31] Investigation of the effect of packing location on performance of closed wet cooling tower based on exergy analysis
    Qasim, S. M.
    Hayder, M. J.
    MODTECH INTERNATIONAL CONFERENCE - MODERN TECHNOLOGIES IN INDUSTRIAL ENGINEERING IV, PTS 1-7, 2016, 145
  • [32] Thermal optimization of a natural draft wet cooling tower
    Williamson, N.
    Behnia, M.
    Armfield, S. W.
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2008, 32 (14) : 1349 - 1361
  • [33] Numerical simulation of hydrodynamics in wet cooling tower packings
    Jourdan, Nicolas
    Kanniche, Mohamed
    Neveux, Thibaut
    Potier, Olivier
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 153 : 194 - 204
  • [34] Experimental Study on Performance of a Closed Wet Cooling Tower for Air Wet-Bulb Temperature near 0°C
    ZHOU Yasu
    ZHANG Pan
    ZHAO Jingde
    YANG Honghai
    BAI Yufeng
    Journal of Thermal Science, 2019, 28 (05) : 1015 - 1023
  • [35] Experimental Study on Performance of a Closed Wet Cooling Tower for Air Wet-Bulb Temperature near 0°C
    Zhou Yasu
    Zhang Pan
    Zhao Jingde
    Yang Honghai
    Bai Yufeng
    JOURNAL OF THERMAL SCIENCE, 2019, 28 (05) : 1015 - 1023
  • [36] Experimental Study on Performance of a Closed Wet Cooling Tower for Air Wet-Bulb Temperature near 0°C
    Yasu Zhou
    Pan Zhang
    Jingde Zhao
    Honghai Yang
    Yufeng Bai
    Journal of Thermal Science, 2019, 28 : 1015 - 1023
  • [37] Simplification of analytical models and incorporation with CFD for the performance predication of closed-wet cooling towers
    Hasan, A
    Gang, GH
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2002, 26 (13) : 1161 - 1174
  • [38] Influence of layout pattern on thermal performance of mechanical draft wet cooling tower group
    Deng, Weipeng
    Sun, Fengzhong
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2023, 184
  • [39] Evaluating vaporization heat, thermal performance, and efficiency of a natural draft wet cooling tower
    Song, Baohong
    Song, Yu
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2022, 236 (06) : 1183 - 1191
  • [40] Influence of non-uniform layout fillings on thermal performance for wet cooling tower
    Gao, Ming
    Zhang, Lei
    Wang, Ni-ni
    Shi, Yue-tao
    Sun, Feng-zhong
    APPLIED THERMAL ENGINEERING, 2016, 93 : 549 - 555