Experimental Assessment of Qualitative Microwave Imaging Using a 3-D Realistic Breast Phantom

被引:0
|
作者
Vasquez, J. A. Tobon [1 ]
Vipiana, F. [1 ]
Casu, M. R. [1 ]
Vacca, M. [1 ]
Sarwar, I. [1 ]
Scapaticci, R. [2 ]
Joachimowicz, N. [3 ]
Duchene, B. [4 ]
机构
[1] Politecn Torino, Dept Elect & Telecommun, I-10129 Turin, Italy
[2] CNR IREA, I-80124 Naples, Italy
[3] Univ Paris Sud, UPMC, Cent Supelec, GeePs,CNRS, Gif Sur Yvette, France
[4] Univ Paris Sud, CNRS, Cent Supelec, L2S, Gif Sur Yvette, France
关键词
Microwave Imaging; Breast Cancer Detection; Breast Phantom;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this work we present an experimental study of qualitative microwave imaging algorithms for breast cancer detection. All the experiments are carried out with a 3-D printed realistic breast phantom filled with designed tissue mimicking liquids. In the following, the first experimental results using the Truncated Singular Value Decomposition (TSVD) scheme and the Linear Sampling Method (LSM) reconstructions are reported.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Detection and Localization of Brain Strokes in Realistic 3-D Human Head Phantom
    Mobashsher, A. T.
    Nguyen, P. T.
    Abbosh, A.
    2013 IEEE MTT-S INTERNATIONAL MICROWAVE WORKSHOP SERIES ON RF AND WIRELESS TECHNOLOGIES FOR BIOMEDICAL AND HEALTHCARE APPLICATIONS (IMWS-BIO), 2013, : 65 - 67
  • [22] Numerical study of microwave induced thermoacoustic imaging for initial detection of cancer of breast on anatomically realistic breast phantom
    Rahpeima, Reza
    Soltani, M.
    Kashkooli, Farshad Moradi
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2020, 196 (196)
  • [23] 3-D Ghost Imaging with Microwave Radar
    Xu, Ran
    Li, Yachao
    Xing, Mengdao
    Shao, Peng
    2014 IEEE INTERNATIONAL CONFERENCE ON IMAGING SYSTEMS & TECHNIQUES (IST), 2014, : 190 - 194
  • [24] Realistic Microwave Breast Models Through T1-Weighted 3-D MRI Data
    Tuncay, Ahmet Hakan
    Akduman, Ibrahim
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2015, 62 (02) : 688 - 698
  • [25] Evaluation of a tumor detection microwave system with a realistic breast phantom
    Koutsoupidou, Maria
    Karanasiou, Irene S.
    Kakoyiannis, Constantine G.
    Groumpas, Evangelos
    Conessa, Christophe
    Joachimowicz, Nadine
    Duchene, Bernard
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2017, 59 (01) : 6 - 10
  • [26] 3-D fluorescence tomography tested in phantom breast model
    Butkus, Benjamin D.
    Biophotonics International, 2003, 10 (07): : 32 - 33
  • [27] Realistic head phantom to test microwave systems for brain imaging
    Mohammed, Beada'a J.
    Abbosh, Amin M.
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2014, 56 (04) : 979 - 982
  • [28] Fabrication of a Realistic Breast Phantom Based on 3D Printing Technology for Thermoacoustic Imaging Application in Breast Cancer Detection
    Wang, Xiong
    Liang, Min
    Witte, Russell S.
    Xin, Hao
    2015 USNC-URSI RADIO SCIENCE MEETING (JOINT WITH AP-S SYMPOSIUM) PROCEEDINGS, 2015, : 17 - 17
  • [29] Low-contrast lesion detection in tomosynthetic breast imaging using a realistic breast phantom
    Zhou, Lili
    Oldan, Jorge
    Fisher, Paul
    Gindi, Gene
    MEDICAL IMAGING 2006: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2006, 6142
  • [30] High-Resolution 3-D Microwave Breast Imaging using Spatial Prior Constraints with Variable Strength
    Neira, Luz Maria
    Van Veen, Barry D.
    Hagness, Susan C.
    2015 IEEE MTT-S INTERNATIONAL CONFERENCE ON NUMERICAL ELECTROMAGNETIC AND MULTIPHYSICS MODELING AND OPTIMIZATION (NEMO), 2015,