Identification of orcein and selected natural dyes in 14th and 15th century liturgical paraments with high-performance liquid chromatography coupled to the electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS)

被引:30
|
作者
Witkowski, Bartlomiej [1 ]
Ganeczko, Monika [1 ]
Hryszko, Helena [2 ]
Stachurska, Monika [2 ]
Gierczak, Tomasz [1 ]
Biesaga, Magdalena [1 ]
机构
[1] Univ Warsaw, Biol & Chem Res Ctr, Fac Chem, Al Zwirki & Wigury 101, PL-02089 Warsaw, Poland
[2] Acad Fine Arts Warsaw, Fac Conservat & Restorat Works Art, Al Wybrzeze Kosciuszkowskie 37, PL-00379 Warsaw, Poland
关键词
Natural dyes; Liquid chromatography; Tandem mass spectrometry; Electrospray ionization; Indigo; Orcein; Medieval silk textiles; NONINVASIVE DIAGNOSTIC-TECHNIQUE; IN-SITU FLUOROMETRY; DEGRADATION-PRODUCTS; HISTORICAL TEXTILES; EXTRACTION METHODS; ORGANIC DYESTUFFS; COLORING MATTERS; INDIGO; MS; FLAVONOIDS;
D O I
10.1016/j.microc.2017.03.049
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, a novel method for identification of orcein derivatives from orchil is presented. It was developed, similarly to other methods used to determine natural dyes, with the use of liquid chromatography coupled to tandem mass spectrometry (LC/MS/MS). Apart from presenting a novel method for orcein derivatives determination, this work also aims to review currently existing method for identification of blue (indigo), red (anthraquinones and brazilwood), and yellow (flavonoids) dyes. In described research, selected reaction monitoring (SRM) conditions were optimized for a number of natural colorants, including the characteristic components of blue (indigo), red (anthraquinones, orchil and brazilwood) and yellow (flavonoids) dyes. For the first time, the major colorants of orchil (orcein derivatives) were analyzed with high performance liquid chromatography (HPLC) coupled to the triple quadrupole mass analyzer. This, made the developed analytical method very sensitive and selective with LOD's values in the range of 0.002 and 0.09 mu g/ml (when pure standards were available). HPLC coupled to the time-of-flight mass analyzer (TOF/MS) was used to define elemental composition of the orcein derivatives at given retention times. The analysis of natural indigo allowed to conclude that indigo prepared using Isatis tinctoria and Indigofera tinctoria contained similar amounts of indirubin. However, the isatin content was significantly higher for Indigofera tinctoria than for Isatis tinctoria. Before analyzing historical samples, analysis of the natural indigo were carried out in order to evaluate if isatis to indigotin ratio can be used to elucidate the plant source of indigo detected in historical samples. Commercial Indigofera indigo powder showed significantly higher value of this ratio (above 0.5) than Isatis tinctoria for which this ratio took values below 0.2. This proportion was used for the identification of blue dye's source. Therefore, the difference in isatin content may be used to identify indigo plant source. This approach requires careful and accurate analysis because isatin is not only a component of natural indigo but also its decomposition product. In this work, the developed analytical protocol was used to successfully identify natural dyes: indigo, brazilwood and orchil in medieval silk textiles (14th and 15th century) from collection of liturgical vestments from Saint Mary's Church in Gdansk (Poland), currently stored in National Museum in Gdansk. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:370 / 379
页数:10
相关论文
共 50 条
  • [21] Identification of anthocyanins in the corona of two species of Passiflora and their hybrid by ultra-high performance chromatography with electrospray ionization tandem mass spectrometry (UHPLC-ESI-MS/MS)
    Baldon Aizza, Lilian Cristina
    Helena Frankland Sawaya, Alexandra Christine
    Dornelas, Marcelo Carnier
    BIOCHEMICAL SYSTEMATICS AND ECOLOGY, 2019, 85 : 60 - 67
  • [22] Determination of warfarin and warfarin alcohols in dried blood spots by ultra-high performance liquid chromatography coupled to electrospray ionization-tandem mass spectrometry (UHPLC-ESI-MS/MS)
    Ghimenti, S.
    Lomonaco, T.
    Biagini, D.
    Bellagambi, F. G.
    Onor, M.
    Trivella, M. G.
    Ruocco, L.
    Pellegrini, G.
    Di Francesco, F.
    Fuoco, R.
    MICROCHEMICAL JOURNAL, 2018, 136 : 247 - 254
  • [23] Identification of indigoid dyes in natural organic pigments used in historical art objects by high-performance liquid chromatography coupled to electrospray ionization mass spectrometry
    Puchalska, M
    Polec-Pawlak, K
    Zadrozna, I
    Hryszko, H
    Jarosz, M
    JOURNAL OF MASS SPECTROMETRY, 2004, 39 (12): : 1441 - 1449
  • [24] High Performance Liquid Chromatography/Electrochemistry/High Resolution Electrospray Ionization-Mass Spectrometry (HPLC/EC/HR ESI-MS) Characterization of Selected Cytokinins Oxidation Products
    Karady, Michal
    Novak, Ondrej
    Horna, Ales
    Strnad, Miroslav
    Dolezal, Karel
    ELECTROANALYSIS, 2015, 27 (02) : 406 - 414
  • [25] High-performance liquid chromatography coupled with electrospray tandem mass spectrometry (LC/MS/MS) method for the simultaneous determination of diazepam, atropine and pralidoxime in human plasma
    Abbara, Chadi
    Bardot, Isabelle
    Cailleux, Annie
    Lallement, Guy
    Le Bouil, Anne
    Turcant, Alain
    Clair, Pascal
    Diquet, Bertrand
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 874 (1-2): : 42 - 50
  • [26] Determination of heterocyclic aromatic amines (HAA) in commercially available meat products and fish by high performance liquid chromatography -: Electrospray tandem mass spectrometry (HPLC-ESI-MS-MS)
    Richling, E
    Häring, D
    Herderich, M
    Schreier, P
    CHROMATOGRAPHIA, 1998, 48 (3-4) : 258 - 262
  • [27] Determination of heterocyclic aromatic amines (HAA) in commercially available meat products and fish by high performance liquid chromatography—Electrospray tandem mass spectrometry (HPLC-ESI-MS-MS)
    E. Richling
    D. Häring
    M. Herderich
    P. Schreier
    Chromatographia, 1998, 48 : 258 - 262
  • [28] Identification of flavonoids in hakmeitau beans (Vigna sinensis) by high-performance liquid chromatography-electrospray mass spectrometry (LC-ESI/MS)
    Chang, Q
    Wong, YS
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2004, 52 (22) : 6694 - 6699
  • [29] Simultaneous determination of fluoxetine, citalopram, paroxetine, venlafaxine in plasma by high performance liquid chromatography-electrospray ionization mass spectrometry (HPLC-MS/ESI)
    He, J
    Zhou, ZL
    Li, HD
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 820 (01): : 33 - 39
  • [30] High Performance Liquid Chromatography-Electrochemistry-Electrospray Ionization Mass Spectrometry (HPLC/EC/ESI-MS) for Detection and Characterization of Roscovitine Oxidation Products
    Karady, Michal
    Novak, Ondrej
    Horna, Ales
    Strnad, Miroslav
    Dolezal, Karel
    ELECTROANALYSIS, 2011, 23 (12) : 2898 - 2905