A new intracoronary measurement catheter, MetriCath, compared to intravascular ultrasound and quantitative coronary angiography in a stented porcine coronary model

被引:5
|
作者
van der Giessen, WJ
Carlier, SG
Regar, E
van Beusekom, HMM
Foley, DP
de Feyter, PJ
Verdouw, PD
Boersma, E
Wolthuis, R
Serruys, PW
机构
[1] Erasmus MC, Thoraxctr, Dept Cardiol, NL-3000 CA Rotterdam, Netherlands
[2] Interuniv Cardiol Inst Netherlands, Utrecht, Netherlands
关键词
pressure volume; coronary dimensions; intravascular ultrasound; quantitative coronary angiography; methodology;
D O I
10.1002/ccd.10242
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this study was to compare measurements by MetriCath to intravascular ultrasound (IVUS) and quantitative coronary angiography (QCA). The MetriCath system consists of a low-pressure (200 mm Hg) balloon catheter connected to a pressure transducer and infusion pump linked to a computer that records pressure-volume curves. Cross-sectional area of blood vessels is obtained directly from the unrestrained and in-stent pressure-volume measurements. We compared stent cross-sectional area measurements by MetriCath, IVUS, and QCA in a porcine stented coronary artery model. Comparison of area measurements in 14 stents showed no significant differences between the three methods (P = 0.66). On average, values differed 0.37 0.60 mm2 between MetriCath and QCA, 0.13 0.55 mm2 between MetriCath and IVUS, and 0.22 0.80 mm2 between IVUS and QCA. This corresponds to 6.2% 10%, 3.0% 9.0%, and 3.1% 12.9% relative difference from the average of two corresponding measurements. Linear regression analysis showed excellent correlation between measurements (r = 0.99 for all comparisons). The differences in in-stent area measurements between MetriCath and both QCA and IVUS were small. Considering the ease and rapidity of obtaining MetriCath results, this technique may form an alternative to the others in evaluating stent expansion. Based on these findings, clinical evaluation seems warranted. 2002 Wiley-Liss, Inc.
引用
收藏
页码:2 / 9
页数:8
相关论文
共 50 条
  • [41] Ultrasound-guided femoral approach for coronary angiography and interventions in the porcine model
    Tsigkas, Grigorios
    Vasilagkos, Georgios
    Tousis, Alexandros
    Theofanis, Michail
    Apostolos, Anastasios
    Spyridonidis, Ioannis
    Goudas, Leonidas
    Karpetas, Georgios
    Moulias, Athanasios
    Katsouras, Christos S.
    Kitrou, Panagiotis
    Mplani, Virginia
    Moulas, Anargyros N.
    Karnabatidis, Dimitrios
    Davlouros, Periklis
    [J]. SCIENTIFIC REPORTS, 2022, 12 (01)
  • [42] INTRAVASCULAR ULTRASOUND VS QUANTITATIVE CORONARY ANGIOGRAPHY - A STATISTICAL COMPARISON OF 538 CONSECUTIVE TARGET LESIONS
    MINTZ, GS
    POPMA, JJ
    DITRANO, CJ
    MACKENZIE, J
    SATLER, LF
    [J]. CIRCULATION, 1993, 88 (04) : 411 - 411
  • [43] INTRAVASCULAR ULTRASOUND IMAGING OF ANGIOGRAPHICALLY NORMAL CORONARY-ARTERIES - AN INVIVO COMPARISON WITH QUANTITATIVE ANGIOGRAPHY
    STGOAR, FG
    PINTO, FJ
    ALDERMAN, EL
    FITZGERALD, PJ
    STADIUS, ML
    POPP, RL
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (04) : 952 - 958
  • [44] INTRAVASCULAR ULTRASOUND VS QUANTITATIVE CORONARY ANGIOGRAPHY - A STATISTICAL COMPARISON OF 1106 CONSECUTIVE TARGET LESIONS
    MINTZ, GS
    POPMA, JJ
    PICHARD, AD
    KENT, KM
    PAINTER, JA
    DEIBLE, R
    ROTH, A
    DITRANO, CJ
    SATLER, LF
    LEON, MB
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, : A270 - A270
  • [45] Comparison of quantitative angiography and intravascular ultrasound after coronary stent implantation with 6 different stents
    Itoh, A
    Hall, P
    Moussa, I
    DiMario, C
    Blengino, S
    Ferraro, M
    Martini, G
    DiFrancesco, L
    Finci, L
    Colombo, A
    [J]. CIRCULATION, 1996, 94 (08) : 1537 - 1537
  • [46] Characteristics of patients with a large discrepancy in coronary artery diameter between quantitative angiography and intravascular ultrasound
    Moussa, I
    Kobayashi, Y
    Adamian, M
    Hirose, M
    Di Mario, C
    Mose, J
    Colombo, A
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2001, 88 (03): : 294 - +
  • [47] DIAMETER MEASUREMENTS AFTER BALLOON ANGIOPLASTY BY INTRAVASCULAR ULTRASOUND AND QUANTITATIVE CORONARY ANGIOGRAPHY - REASONS FOR DISCREPANCIES
    MUDRA, H
    BLASINI, R
    KLAUSS, V
    REGAR, E
    RIEBER, J
    KONIG, A
    ROTH, M
    VONESSEN, R
    THEISEN, K
    [J]. CIRCULATION, 1993, 88 (04) : 411 - 411
  • [48] Prospective deep learning-based quantitative assessment of coronary plaque by computed tomography angiography compared with intravascular ultrasound: the REVEALPLAQUE study
    Narula, Jagat
    Stuckey, Thomas D.
    Nakazawa, Gaku
    Ahmadi, Amir
    Matsumura, Mitsuaki
    Petersen, Kersten
    Mirza, Saba
    Ng, Nicholas
    Mullen, Sarah
    Schaap, Michiel
    Leipsic, Jonathan
    Rogers, Campbell
    Taylor, Charles A.
    Yacoub, Harout
    Gupta, Himanshu
    Matsuo, Hitoshi
    Rinehart, Sarah
    Maehara, Akiko
    [J]. EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2024, 25 (09) : 1287 - 1295
  • [49] The effect of intracoronary β-radiation dose on neointimal formation and percent area stenosis in a stented porcine coronary restenosis model.
    Ali, NM
    Buergler, JM
    Raizner, AE
    [J]. CIRCULATION, 1998, 98 (17) : 676 - 676
  • [50] The effect of intracoronary β-radiation dose on neointimal formation and percent area stenosis in a stented porcine coronary restenosis model.
    Ali, NM
    Kaluza, G
    Mazur, W
    Raizner, AE
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1998, 82 (7A): : 21S - 21S