Controlling the flow distribution characteristics in the secondary air system of a gas turbine

被引:4
|
作者
Lee, Jungsoo [1 ]
Kim, Seongmin [1 ]
Kim, Donghwa [2 ]
Cho, GeonHwan [3 ]
Cho, Jinsoo [1 ]
机构
[1] Hanyang Univ, Dept Mech Engn, Seoul, South Korea
[2] Agcy Def Dev, R&D Inst 4, Daegeon, South Korea
[3] Doosan Heavy Ind & Construct, Gas Turbine Syst Integrat Team, Chang Won, South Korea
关键词
Adiabatic effectiveness; Discharge coefficient; Pre-swirl system; Receiver hole; Secondary air system; HEAT-TRANSFER; OPTIMIZATION; MODEL;
D O I
10.1016/j.ijheatfluidflow.2022.108973
中图分类号
O414.1 [热力学];
学科分类号
摘要
Increased gas turbine system efficiency is accompanied by increases in turbine inlet temperature, mass flow rate, and pressure. Because the turbine blade is exposed to high temperatures and high pressure, the secondary air system (SAS) should be designed to optimize operating conditions and blade life. The cooling air discharged from the compressor flows into the rotating disk through the pre-swirl system, then into the receiver holes during the respective stage of the turbine. In this study, the flow distribution characteristics of the secondary cooling air, which flows into the first-stage turbine blade and the second-stage cavity, were analyzed using validated computational fluid dynamics (CFD) methodology. CFD techniques were validated by comparative analysis of various CFD techniques on the experimental data of Bath University and Hanyang University in the previous studies. To apply the k-omega SST turbulence model, which was the most effective technique, the grids near the wall was constructed with y(+) one or less. The frozen rotor method was applied to the stationary-rotating interface to satisfy the change in pitch ratio for each components. As a result, methodologies had been devised to control each flow properties while maintaining SAS efficiency through a change in system outlet area. When the swirl ratio was maintained at one, it was possible to change the mass flow rate for the outlet area without reducing the system efficiency. On the other hand, the outlet static pressure could be changed for the outlet area regardless of the swirl ratio, but the choked flow occurred below a specific pressure ratio. Finally, mass flow rate and static pressure at the receiver hole outlet could be controlled respectively, and the performance curves of the SAS within the designable range were also presented.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Analysis of flow field and aerodynamic noise of marine gas turbine air intake system
    Luan, Yigang
    Yan, Lanyi
    Sun, Tao
    Zunino, Pietro
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2023, 154 (02): : 886 - 901
  • [22] Heavy duty gas turbine simulation: Global performances estimation and secondary air system modifications
    Carcasci, Carlo
    Facchini, Bruno
    Gori, Stefano
    Bozzi, Luca
    Traverso, Stefano
    Proceedings of the ASME Turbo Expo 2006, Vol 4, 2006, : 527 - 536
  • [23] Probabilistic analysis of stationary gas turbine secondary air systems
    Bischoff, Thomas
    Voigt, Matthias
    Chehab, Ed
    Vogeler, Konrad
    Proceedings of the ASME Turbo Expo 2006, Vol 3, Pts A and B: HEAT TRANSFER: GENERAL INTEREST, 2006, : 1365 - 1373
  • [24] Generalized characteristics of gas turbine compressed air generators
    Bikbulatov, AM
    Ar'kov, YG
    Shaikhutdinov, DK
    IZVESTIYA VYSSHIKH UCHEBNYKH ZAVEDENII AVIATSIONAYA TEKHNIKA, 2002, (03): : 62 - 64
  • [25] Generalized characteristics of gas turbine compressed air generators
    Bikbulatov, A.M.
    Ar'kov, Yu.G.
    Shajkhutdinov, D.Kh.
    Izvestiya Vysshikh Uchebnykh Zavedenij. Aviatsionnaya Tekhnika, 2002, (03): : 62 - 65
  • [26] Typical Characteristics of Gas Turbine-based CCHP System with Inlet Air Cooling
    Zeng, Fei
    Yang, Cheng
    Yang, Zeliang
    2011 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2011,
  • [27] Combustion characteristics of pressurized methane-air combustor for chemical gas turbine system
    Furuhata, T
    Miyazaki, T
    Kobayashi, N
    Arai, N
    Bujar, D
    Tanno, S
    Miura, T
    HEAT TRANSFER 1998, VOL 7: GENERAL PAPERS, 1998, : 283 - 288
  • [28] The analyses on operation characteristics and application of gas turbine dual source air conditioning system
    Wang, Xi
    Yang, Yong-Ping
    Song, Zhi-Ping
    Xu, Er-Shu
    Bi, Qing-Sheng
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2010, 31 (05): : 745 - 748
  • [29] Parametric Studies on Gas Turbine Labyrinth Seal for the Secondary Air Flow Optimization at Static and Rotating Conditions
    Kaliraj, Karthick Raja
    Yepuri, Giridhara Babu
    Sarasamma, Jayakumar Janardanan
    Kumar, Kishor
    Jesuraj, Felix
    PROCEEDINGS OF THE ASME GAS TURBINE INDIA CONFERENCE, 2019, VOL 1, 2020,
  • [30] A novel combined model for energy consumption performance prediction in the secondary air system of gas turbine engines based on flow resistance network
    Gong, Wenbin
    Lei, Zhao
    Nie, Shunpeng
    Liu, Gaowen
    Lin, Aqiang
    Feng, Qing
    Wang, Zhiwu
    ENERGY, 2023, 280