Overlay metrology tool calibration - art. no. 65180I

被引:4
|
作者
Binns, L. A.
Dasari, P.
Smith, N. P.
Ananew, G.
Fink, H.
机构
关键词
overlay metrology; optical calibration; tool matching;
D O I
10.1117/12.712769
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In a previous publication, we introduced Blossom, a multi-layer overlay mark (Ausschnitt, et al. 2006, [1]). Through further testing carried out since that publication, Blossom has been shown to meet the requirements on current design rules (Ausschnitt, et al. 2007, [2]), while giving some unique benefits. However, as future design rules shrink, efforts must be made now to ensure the extensibility of the Blossom technology. Previous work has shown that the precision component of Total Measurement Uncertainty (TMU) can be reduced by using extra redundancy in the target design, to achieve performance beyond that of a conventional box-in-box measurement. However, improvements that single contributor to TMU would not be sufficient for future design rules; therefore we have also to consider the Tool Induced Shift (TIS) variability and tool to tool matching contributions to TMU. In this paper, we introduce a calibration artifact, based on the Blossom technology. The calibration artifact is both compact, and produced by standard lithography process, so it can be placed in a production scribe line if required, reducing the need for special sets of calibration wafers compared to other possible calibration methodologies. Calibration is currently with respect to the exposure tool / process / mask, which is arguably more pertinent to good yield, and less expensive, than calibration to an external standard; externally calibrated artifacts would be straightforward to manufacture if needed. By using this artifact, we can map out remaining optical distortions within an overlay tool, to a precision significantly better than the operational tool precision, in a way that directly relates to overlay performance. The effect of process-induced mark uncertainties on calibration can be reduced by performing measurements on a large number of targets; by taking multiple measurements of each target we can also use the artifact to evaluate the current levels of process induced mark uncertainty. The former result leads to an improvement method for TIS and matching capability. We describe the artifact and its usage, and present results from a group of operational overlay tools. We show how the use of this information also provides further insight into the layout optimizations discussed previously (Binns et al. 2006 [3]). It provides the current limits of measurement precision and mark fidelity with respect to target redundancy, enabling us to use a predictive cost-benefit term in the optimization. Finally, examining the bulk behaviour of a fleet of overlay tools, allows us to examine how future mark layouts can also contribute to minimizing TMU rather than just precision.
引用
收藏
页码:I5180 / I5180
页数:9
相关论文
共 50 条
  • [21] The WISE In-orbit Calibration - art. no. 70161N
    Fabinsky, Beth
    Heinrichsen, Ingolf
    Mainzer, Amy
    Eisenhardt, Peter
    OBSERVATORY OPERATIONS: STRATEGIES, PROCESSES, AND SYSTEMS II, 2008, 7016 : N161 - N161
  • [22] Calibration of the length of a chain of single gold atoms -: art. no. 085418
    Untiedt, C
    Yanson, AI
    Grande, R
    Rubio-Bollinger, G
    Agraït, N
    Vieira, S
    van Ruitenbeek, JM
    PHYSICAL REVIEW B, 2002, 66 (08): : 854181 - 854186
  • [23] Polarization scattering from a Spectralon calibration sample - art. no. 668219
    Noble, Hannah
    Lam, Wai-Sze Tiffany
    Smith, Greg
    McClain, Stephen
    Chipman, Russell A.
    POLARIZATION SCIENCE AND REMOTE SENSING III, 2007, 6682 : 68219 - 68219
  • [24] Enhancements to FDTD modeling for optical metrology applications - art. no. 66170U
    Salski, Bartlomiej
    Celuch, Malgorzata
    Gwarek, Wojciech
    Modeling Aspects in Optical Metrology, 2007, 6617 : U6170 - U6170
  • [25] The limits of image-based optical metrology - art. no. 61520Z
    Silver, R. M.
    Barnes, B. M.
    Attota, R.
    Jun, J.
    Filliben, J.
    Soto, J.
    Stocker, M.
    Lipscomb, P.
    Marx, E.
    Patrick, H. J.
    Dixson, R.
    Larrabee, R.
    Metrology, Inspection, and Process Control for Microlithography XX, Pts 1 and 2, 2006, 6152 : Z1520 - Z1520
  • [26] Metrology for templates of UV nano imprint lithography - art. no. 67305O
    Yoshida, Konji
    Kojinia, Kouichirou
    Abe, Makoto
    Sasaki, Shiho
    Kurihara, Masaaki
    Mohri, Hiroshi
    Hayashi, Naoya
    PHOTOMASK TECHNOLOGY 2007, PTS 1-3, 2007, 6730 : O7305 - O7305
  • [27] Multi-Wavelength digital holographic metrology - art. no. 63111D
    Aleksoff, Carl C.
    Optical Information Systems IV, 2006, 6311 : D3111 - D3111
  • [28] Camera calibration method used in computer vision coordinate measurement systems - art. no. 68291I
    Yu, Zhijing
    Li, Xinxin
    Tian, Wei
    Gong, Miao
    He, Dongrui
    Xia, Lingli
    ADVANCED MATERIALS AND DEVICES FOR SENSING AND IMAGING III, 2008, 6829 : I8291 - I8291
  • [29] A proposed standard method for polarimetric calibration and calibration verification - art. no. 66820K
    Persons, Christopher M.
    Jones, Michael W.
    Farlow, Craig A.
    Morell, L. Denise
    Gulley, Michael G.
    Spradley, Kevin D.
    POLARIZATION SCIENCE AND REMOTE SENSING III, 2007, 6682 : K6820 - K6820
  • [30] Slide projector calibration based on calibration of digital camera - art. no. 67882K
    Tao, Jun
    MIPPR 2007: PATTERN RECOGNITION AND COMPUTER VISION, 2007, 6788 : K7882 - K7882