Measurement of carotid stenosis: Comparisons between duplex and different angiographic grading methods
被引:19
|作者:
Hwang, CS
Liao, KM
Lee, JH
Tegeler, CH
机构:
[1] Chung Hsiao Municipal Hosp, Dept Neurol, Taipei, Taiwan
[2] Chung Hsiao Municipal Hosp, Dept Internal Med, Taipei, Taiwan
[3] Natl Taiwan Univ, Grad Inst Clin Med, Coll Med, Taipei, Taiwan
[4] Yonsei Univ, Coll Med, Dept Neurol, Natl Hlth Insurance Corp,Ilsan Hosp, Seoul 120749, South Korea
[5] Wake Forest Univ, Dept Neurol, Baptist Med Ctr, Winston Salem, NC 27109 USA
关键词:
carotid stenosis;
angiography;
ultrasonic;
D O I:
10.1177/1051228403251087
中图分类号:
R74 [神经病学与精神病学];
学科分类号:
摘要:
Background and Purpose. Endarterectomy has been proved to be an effective stroke prevention procedure. However, there are still inconsistencies between the results of different preoperative evaluation methods, which may sometimes complicate treatment plans. This study measured the discrepancies between different angiographic grading methods and attempted to further assess the accuracy of the carotid duplex examination according to these different angiographic grading methods. Methods. One hundred seventy-one preendarterectomy carotid duplex examinations and angiograms were reviewed. All angiograms were measured blindly by one of the authors using the North American Symptomatic Carotid Endarterectomy Trial (N), the European Carotid Surgery Trial (E), and the common carotid (C) methods. The measurement results were further converted into the area of stenosis indices (N-2, E-2, and C-2, respectively). By using regression testing, all results could be compared. The duplex examination data were then compared with the results of different angiographic measurement methods to evaluate their accuracy. Results. The measurement results of all angiographic grading methods were well correlated. Using different angiographic grading systems as the gold standard, duplex examination for screening endarterectomy candidates produced the following results: According to the N method, accuracy was 74%; according to the E method, accuracy was 90%; and according to the C method, the accuracy rate was 2 92%. According to N-2, accuracy was 88%; according to E-2 accuracy was 94%; and according to C-2, the accuracy rate was 93%. Conclusions. The measurement results of all 3 commonly used angiographic grading methods were linearly correlated with one another. (It is important to note that none of those standards should be treated as the only gold standard.) In this study, the duplex criteria have a greater accuracy rate according to E or C rather than N. However, this study also demonstrated that the cut point of the Doppler criteria is the determinant factor for accuracy rather than which gold standard was compared. Through careful adjustment of the cutoff criteria, carotid duplex can be highly accurate, despite the use of different reference standards.
引用
收藏
页码:133 / 139
页数:7
相关论文