Measurement of carotid stenosis: Comparisons between duplex and different angiographic grading methods

被引:19
|
作者
Hwang, CS
Liao, KM
Lee, JH
Tegeler, CH
机构
[1] Chung Hsiao Municipal Hosp, Dept Neurol, Taipei, Taiwan
[2] Chung Hsiao Municipal Hosp, Dept Internal Med, Taipei, Taiwan
[3] Natl Taiwan Univ, Grad Inst Clin Med, Coll Med, Taipei, Taiwan
[4] Yonsei Univ, Coll Med, Dept Neurol, Natl Hlth Insurance Corp,Ilsan Hosp, Seoul 120749, South Korea
[5] Wake Forest Univ, Dept Neurol, Baptist Med Ctr, Winston Salem, NC 27109 USA
关键词
carotid stenosis; angiography; ultrasonic;
D O I
10.1177/1051228403251087
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose. Endarterectomy has been proved to be an effective stroke prevention procedure. However, there are still inconsistencies between the results of different preoperative evaluation methods, which may sometimes complicate treatment plans. This study measured the discrepancies between different angiographic grading methods and attempted to further assess the accuracy of the carotid duplex examination according to these different angiographic grading methods. Methods. One hundred seventy-one preendarterectomy carotid duplex examinations and angiograms were reviewed. All angiograms were measured blindly by one of the authors using the North American Symptomatic Carotid Endarterectomy Trial (N), the European Carotid Surgery Trial (E), and the common carotid (C) methods. The measurement results were further converted into the area of stenosis indices (N-2, E-2, and C-2, respectively). By using regression testing, all results could be compared. The duplex examination data were then compared with the results of different angiographic measurement methods to evaluate their accuracy. Results. The measurement results of all angiographic grading methods were well correlated. Using different angiographic grading systems as the gold standard, duplex examination for screening endarterectomy candidates produced the following results: According to the N method, accuracy was 74%; according to the E method, accuracy was 90%; and according to the C method, the accuracy rate was 2 92%. According to N-2, accuracy was 88%; according to E-2 accuracy was 94%; and according to C-2, the accuracy rate was 93%. Conclusions. The measurement results of all 3 commonly used angiographic grading methods were linearly correlated with one another. (It is important to note that none of those standards should be treated as the only gold standard.) In this study, the duplex criteria have a greater accuracy rate according to E or C rather than N. However, this study also demonstrated that the cut point of the Doppler criteria is the determinant factor for accuracy rather than which gold standard was compared. Through careful adjustment of the cutoff criteria, carotid duplex can be highly accurate, despite the use of different reference standards.
引用
下载
收藏
页码:133 / 139
页数:7
相关论文
共 50 条
  • [1] Angiographic and duplex grading of internal carotid stenosis: Can we overcome the confusion?
    Nicolaides, AN
    Shifrin, EG
    Bradbury, A
    Dhanjil, S
    Griffin, M
    Belcaro, G
    Williams, M
    JOURNAL OF ENDOVASCULAR SURGERY, 1996, 3 (02): : 158 - 165
  • [2] The Implications of Different Criteria for Grading Carotid Artery Stenosis by Duplex Ultrasound
    Gray, Cleona
    Murray, Sorcha A.
    Connolly, Mary
    O'Donohoe, Martin K.
    McDonnell, Ciaran O.
    Badger, Stephen A.
    JOURNAL OF CLINICAL ULTRASOUND, 2015, 43 (09) : 563 - 566
  • [3] Duplex Criteria for Grading of External Carotid Stenosis
    Shmelev, Artem
    Ganti, Avinash
    Hosseini, Motahar
    Wilkerson, Donald
    Darwazeh, Ghaleb
    Zatina, Michael
    ANNALS OF VASCULAR SURGERY, 2020, 63 : 319 - 324
  • [4] COMBINATION OF CAROTID DUPLEX AND TRANSCRANIAL DOPPLER FOR THE ASSESSMENT OF CAROTID STENOSIS - A CORRELATION WITH NASCET ANGIOGRAPHIC MEASUREMENT
    HIRSCH, R
    LEE, DH
    STROKE, 1994, 25 (01) : 250 - 250
  • [5] Comparisons between carotid duplex sonography and cerebral angiography in assessing the degree of carotid stenosis
    Fox, AJ
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2000, 21 (04) : 618 - 619
  • [6] Grading Carotid Stenosis Using Ultrasonic Methods
    von Reutern, Gerhard-Michael
    Goertler, Michael-Wolfgang
    Bornstein, Natan M.
    Del Sette, Massimo
    Evans, David H.
    Hetzel, Andreas
    Kaps, Manfred
    Perren, Fabienne
    Razumovky, Alexander
    von Reutern, Michael
    Shiogai, Toshiyuki
    Titianova, Ekaterina
    Traubner, Pavel
    Venketasubramanian, Narayanaswamy
    Wong, Lawrence K. S.
    Yasaka, Masahiro
    STROKE, 2012, 43 (03) : 916 - 921
  • [7] Variability of angiographic measurements of internal carotid artery stenosis between methods and observers
    Fox, AD
    Robbins, SE
    Whiteley, MS
    Modi, P
    Collin, J
    BRITISH JOURNAL OF SURGERY, 1998, 85 (04) : 567 - 567
  • [8] Ageing Affects the Accuracy of Duplex Ultrasonography in Grading Carotid Artery Stenosis
    Schreuder, Floris H. B. M.
    Mess, Werner H.
    Hoeks, Arnold P. G.
    CEREBROVASCULAR DISEASES, 2009, 27 (01) : 75 - 83
  • [9] COMBINED TRANSCRANIAL DOPPLER AND CAROTID DUPLEX ULTRASOUND BEST PREDICTS DEGREE OF ANGIOGRAPHIC CAROTID STENOSIS
    WILTERDINK, JL
    FELDMANN, E
    FURIE, KL
    BRAGONI, M
    BENAVIDES, JG
    WILCOCK, C
    WARD, R
    ANNALS OF NEUROLOGY, 1994, 36 (02) : 266 - 266
  • [10] Carotid duplex criteria for a 60% or greater angiographic stenosis: Variation according to equipment
    Fillinger, MF
    Baker, RJ
    Zwolak, RM
    Musson, A
    Lenz, JE
    Mott, J
    Bech, FR
    Walsh, DB
    Cronenwett, JL
    JOURNAL OF VASCULAR SURGERY, 1996, 24 (05) : 856 - 864