Improving Filtered Backprojection Reconstruction by Data-Dependent Filtering

被引:32
|
作者
Pelt, Daniel M. [1 ]
Batenburg, Kees Joost [1 ,2 ,3 ]
机构
[1] Ctr Wiskunde & Informat, NL-1090 GB Amsterdam, Netherlands
[2] Leiden Univ, Math Inst, NL-2311 EZ Leiden, Netherlands
[3] Univ Antwerp, iMinds Vis Lab, B-2610 Antwerp, Belgium
关键词
Tomography; image reconstruction; algebraic methods; TOMOGRAPHIC RECONSTRUCTION; COMPUTED-TOMOGRAPHY; ALGORITHM;
D O I
10.1109/TIP.2014.2341971
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Filtered backprojection, one of the most widely used reconstruction methods in tomography, requires a large number of low-noise projections to yield accurate reconstructions. In many applications of tomography, complete projection data of high quality cannot be obtained, because of practical considerations. Algebraic methods tend to handle such problems better, but are computationally more expensive. In this paper, we introduce a new method that improves the filtered backprojection method by using a custom data-dependent filter that minimizes the projection error of the resulting reconstruction. We show that the computational cost of the new method is significantly lower than that of algebraic methods. Experiments on both simulation and experimental data show that the method is able to produce more accurate reconstructions than filtered backprojection based on popular static filters when presented with data with a limited number of projections or statistical noise present. Furthermore, the results show that the method produces reconstructions with similar accuracy to algebraic methods, but is faster at producing them. Finally, we show that the method can be extended to exploit certain forms of prior knowledge, improving reconstruction accuracy in specific cases.
引用
收藏
页码:4750 / 4762
页数:13
相关论文
共 50 条
  • [41] Improved attenuation correction method for SPECT by iterative filtered backprojection reconstruction
    Chuang, K.
    Lue, K.
    Lin, H.
    Wang, H.
    Ni, Y.
    Jan, M.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S366 - S366
  • [42] Efficient Bandwidth Estimation in 2D Filtered Backprojection Reconstruction
    Maitra, Ranjan
    [J]. IEEE TRANSACTIONS ON IMAGE PROCESSING, 2019, 28 (11) : 5610 - 5619
  • [43] Data-dependent weighted median filtering with motion information for image sequence restoration
    Meguro, M
    Taguchi, A
    Hamada, N
    [J]. NONLINEAR IMAGE PROCESSING X, 1999, 3646 : 228 - 239
  • [44] Exact gram filtering and efficient backprojection for iterative CT reconstruction
    Shu, Ziyu
    Entezari, Alireza
    [J]. MEDICAL PHYSICS, 2022, 49 (05) : 3080 - 3092
  • [45] Consideration on image reconstruction of backprojection filtering in the spatial frequency domain
    Suzuki, S
    Wakabayashi, M
    [J]. MEDICAL PHYSICS, 1996, 23 (09) : 1643 - 1645
  • [46] Best data-dependent triangulations
    Alboul, L
    Kloosterman, G
    Traas, C
    van Damme, R
    [J]. JOURNAL OF COMPUTATIONAL AND APPLIED MATHEMATICS, 2000, 119 (1-2) : 1 - 12
  • [47] Motion-compensated reconstruction based on filtered backprojection for helical head CT
    Jang, Seokhwan
    Kim, Seungeon
    Chang, Yongjin
    Ra, Jong Beom
    [J]. MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [48] Iterative reconstruction compared to filtered backprojection in Tl-201-myocard-SPECT
    Lobinger, B
    Kaiser, W
    Reuland, P
    Feine, U
    MullerSchauenburg, W
    Hoffmeister, HM
    [J]. PERFUSION, 1996, 9 (04): : 136 - 139
  • [49] Predicting data-dependent jitter
    Buckwalter, J
    Analui, B
    Hajimiri, A
    [J]. IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS II-EXPRESS BRIEFS, 2004, 51 (09) : 453 - 457
  • [50] COMPARISON OF ITERATIVE FILTERED BACKPROJECTION AND WEIGHTED LEAST-SQUARES RECONSTRUCTION METHODS
    LALUSH, DS
    TSUI, BMW
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (05) : P28 - P28