Diagnostic Performance of MRI Versus Galactography in Women With Pathologic Nipple Discharge: A Systematic Review and Meta-Analysis

被引:51
|
作者
Berger, Nicole [1 ,2 ]
Luparia, Andrea [2 ]
Di Leo, Giovanni [3 ]
Carbonaro, Luca Alessandro [3 ]
Trimboli, Rubina Manuela [4 ]
Ambrogi, Federico [5 ]
Sardanelli, Francesco [3 ,6 ]
机构
[1] Univ Hosp Zurich, Inst Diagnost & Intervent Radiol, Raemistr 100, CH-8091 Zurich, Switzerland
[2] Azienda Prov & Serv Sanit Prov Autonoma Trento, Dipartimento Radiodiagnost, Unita Operat Senol Clin & Screening Mammog, Trento, Italy
[3] IRCCS Policlin San Donato, Unit Radiol, Milan, Italy
[4] Univ Milan, Integrat Biomed Res, Milan, Italy
[5] Univ Milan, Dept Clin Sci & Community Hlth, Milan, Italy
[6] Univ Milan, Dept Biomed Sci Hlth, Milan, Italy
关键词
breast; galactography; MRI; pathologic nipple discharge; systematic review; BREAST MRI; UNILATERAL BLOODY; DUCTOGRAPHY; MAMMOGRAPHY; DUCTOSCOPY;
D O I
10.2214/AJR.16.16682
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The objective of our study was to perform a systematic review of the literature of the diagnostic accuracy of MRI compared with galactography in women with pathologic nipple discharge. MATERIALS AND METHODS. A systematic literature search was performed (MEDLINE, Embase, Web of Science) for articles evaluating the diagnostic performance of MRI and galactography in patients with pathologic nipple discharge and with histologic verification or clinical follow-up. Distinction between any abnormality and cancer was made. Two independent readers selected eligible articles published until December 2015. The quality of the studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool. Data analyses were performed using the bivariate model. RESULTS. Ten articles were analyzed for a total of 921 patients. The study quality was high, with a low risk of bias and low concerns regarding applicability. The pooled sensitivity for any abnormality was significantly higher for MRI, with 92% (95% CI, 85-96%), than for galactography, with 69% (95% CI, 59-78%) (p < 0.001). The pooled specificity was 76% (95% CI, 49-92%) for MRI versus 39% (95% CI, 16-69%) for galactography (p < 0.001). The pooled sensitivity and specificity for cancer detection were calculated for MRI only and were 92% (95% CI, 74-98%) and 97% (95% CI, 80-100%), respectively. CONCLUSION. This meta-analysis shows a higher diagnostic performance of MRI compared with that of galactography in the detection of any kind of lesion in patients with pathologic nipple discharge. Moreover, high sensitivity and very high specificity for cancer by MRI could be confirmed in this clinical setting. If mammography and ultrasound are negative, MRI should be preferred over galactography for further evaluation.
引用
收藏
页码:465 / 471
页数:7
相关论文
共 50 条
  • [31] Diagnostic performance of MRI, SPECT, and PET in detecting renal cell carcinoma: a systematic review and meta-analysis
    Yin, Qihua
    Xu, Huiting
    Zhong, Yanqi
    Ni, Jianming
    Hu, Shudong
    BMC CANCER, 2022, 22 (01)
  • [32] Lesions of Ligamentum Teres: Diagnostic Performance of MRI and MR Arthrography-A Systematic Review and Meta-Analysis
    Shakoor, Delaram
    Farahani, Sahar J.
    Hafezi-Nejad, Nima
    Johnson, Alex
    Vaidya, Dhananjay
    Khanuja, Harpal S.
    Eng, John
    Demehri, Shadpour
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 211 (01) : W52 - W63
  • [33] Diagnostic performance of Kaiser score in the evaluation of breast cancer using MRI: A systematic review and meta-analysis
    Mohammadzadeh, Saeed
    Mohebbi, Alisa
    Moradi, Zahra
    Abdi, Ali
    Mohammadi, Afshin
    Hakim, Peyman Kamali
    Ahmadinejad, Nasrin
    Zeinalkhani, Fahimeh
    EUROPEAN JOURNAL OF RADIOLOGY, 2025, 186
  • [34] Diagnostic Performance of MRI in the Detection of Renal Lipid-Poor Angiomyolipomas: A Systematic Review and Meta-Analysis
    Wilson, Mitchell P.
    Patel, Deelan
    Murad, Mohammad H.
    McInnes, Matthew D. F.
    Katlariwala, Prayash
    Low, Gavin
    RADIOLOGY, 2020, 296 (03) : 511 - 520
  • [35] Diagnostic performance of MRI in detecting locally recurrent soft tissue sarcoma: systematic review and meta-analysis
    Robert M. Kwee
    Thomas C. Kwee
    European Radiology, 2022, 32 : 3915 - 3930
  • [36] Outcomes of robotic nipple-sparing mastectomy versus conventional nipple-sparing mastectomy in women with breast cancer: a systematic review and meta-analysis
    Gabriel De la Cruz-Ku
    Diego Chambergo-Michilot
    Armando Perez
    Bryan Valcarcel
    Larissa Pamen
    David Linshaw
    Abhishek Chatterjee
    Jennifer LaFemina
    Judy C. Boughey
    Journal of Robotic Surgery, 2023, 17 : 1493 - 1509
  • [37] Diagnostic Accuracy of MRI for Solid Renal Masses: A Systematic Review and Meta-analysis
    Frank, Robert A.
    Dawit, Haben
    Bossuyt, Patrick M. M.
    Leeflang, Mariska
    Flood, Trevor A.
    Breau, Rodney H.
    McInnes, Matthew D. F.
    Schieda, Nicola
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2023, 57 (04) : 1172 - 1184
  • [38] Outcomes of robotic nipple-sparing mastectomy versus conventional nipple-sparing mastectomy in women with breast cancer: a systematic review and meta-analysis
    de la Cruz-ku, Gabriel
    Chambergo-Michilot, Diego
    Perez, Armando
    Valcarcel, Bryan
    Pamen, Larissa
    Linshaw, David
    Chatterjee, Abhishek
    LaFemina, Jennifer
    Boughey, Judy C.
    JOURNAL OF ROBOTIC SURGERY, 2023, 17 (04) : 1493 - 1509
  • [39] Diagnostic performance of serum cobalamin tests: a systematic review and meta-analysis
    Willis, Cameron D.
    Elshaug, Adam G.
    Milverton, Joanne L.
    Watt, Amber M.
    Metz, Michael P.
    Hiller, Janet E.
    PATHOLOGY, 2011, 43 (05) : 472 - 481
  • [40] Diagnostic performance of peripheral arterial tonometry: A systematic review and meta-analysis
    Rattanamongkolsak, Ninlaya
    Rattanasiri, Sasivimol
    Tantrakul, Visasiri
    Numthavaj, Pawin
    JOURNAL OF SLEEP RESEARCH, 2024, 33