Control Implementation of the Full-Scale Wind Power Converter without Grid Voltage Sensors

被引:0
|
作者
Zhang, Jianwen [1 ]
Wang, Han [1 ]
Zhu, Miao [1 ]
Cai, Xu [1 ]
机构
[1] Shanghai Jiao Tong Univ, Dept Elect Engn, Shanghai 200240, Peoples R China
关键词
wind active damping; grid-connected inverter (GCI); LCL-filter; power generation; voltage-sensorless control; virtualflux observing; SOGI; LCL; FILTER; DESIGN; GENERATION; INVERTERS;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In order to save sensors for the grid-connected inverter (GCI) with LCL-filter in the full-scale wind power converter, a grid-side voltage-sensorless solution scheme is presented in this paper. A frequency-adaptive SOGI (FA-SOGI) is introduced to realize the virtual flux (VF) estimation. A grid-side voltage observer is thus designed to acquire the phase angle and amplitude, which can realize voltage orientation control (VOC) for the GCI system. With an improved feedback damping method for LCL filter, a full control strategy of the full-scale wind power generation system is given and explained in detail. All theoretical results have been validated by the simulation, followed by analysis and discussion.
引用
收藏
页码:1753 / 1760
页数:8
相关论文
共 50 条
  • [41] FULL-SCALE IMPLEMENTATION OF ACTIVE CONTROL .2. INSTALLATION AND PERFORMANCE
    REINHORN, AM
    SOONG, TT
    RILEY, MA
    LIN, RC
    AIZAWA, S
    HIGASHINO, M
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1993, 119 (06): : 1935 - 1960
  • [42] A Model Predictive Control Method for Grid-Connected Power Converters Without AC Voltage Sensors
    Guo, Leilei
    Jin, Nan
    Li, Yanyan
    Luo, Kui
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2021, 68 (02) : 1299 - 1310
  • [43] Circuit Implementation Enabling Full-Scale Linear Sensing in Mode-Localized Sensors
    Guo, Xin
    Li, Ang
    Gong, Hui
    Hu, Weiming
    Li, Zizheng
    Song, Xiang
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73 : 1 - 12
  • [44] Mechanism of frequency instability of full-scale wind turbines caused by grid short circuit fault and its control method
    Han G.
    Zhang C.
    Cai X.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2018, 33 (10): : 2167 - 2175
  • [45] Hierarchical automatic voltage control for integration of large-scale wind power: Design and implementation
    Guo, Qinglai
    Sun, Hongbin
    Wang, Bin
    Zhang, Boming
    Wu, Wenchuan
    Tang, Lei
    ELECTRIC POWER SYSTEMS RESEARCH, 2015, 120 : 234 - 241
  • [46] PERSPECTIVES ON FULL-SCALE MEASUREMENT OF WIND EFFECTS
    DAVENPORT, AG
    JOURNAL OF INDUSTRIAL AERODYNAMICS, 1975, 1 (01): : 23 - 54
  • [47] MEASUREMENTS OF WIND LOADS ON FULL-SCALE GLASSHOUSES
    WELLS, DA
    HOXEY, RP
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1980, 6 (1-2) : 139 - 167
  • [48] Robust DC-Link Voltage Control of a Full-Scale PMSG Wind Turbine for Effective Integration in DC Grids
    Davari, Masoud
    Mohamed, Yasser Abdel-Rady I.
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (05) : 4021 - 4035
  • [49] Full-scale measurements for wind effects on buildings
    Mehta, KC
    Smith, DA
    ENGINEERING, CONSTRUCTION AND OPERATIONS IN CHALLENGING ENVIRONMENTS: EARTH AND SPACE 2004, 2004, : 190 - 194
  • [50] Grid Voltage Estimation and Current Control of a Single-Phase Grid-Connected Converter Without Grid Voltage Sensor
    Mukherjee, Subhajyoti
    Chowdhury, Vikram Roy
    Shamsi, Pourya
    Ferdowsi, Mehdi
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2018, 33 (05) : 4407 - 4418