The CERES 8-12 micron window channel

被引:0
|
作者
Smith, GL [1 ]
Bess, TD
Manalo-Smith, N
Ramanathan, V
Lee, RB
Barkstrom, BR
机构
[1] Virginia Polytech Inst & State Univ, Dept Mech Engn, Blacksburg, VA 24061 USA
[2] NASA, Langley Res Ctr, Hampton, VA 23665 USA
[3] NASA, Langley Res Ctr, Hampton, VA 23665 USA
[4] Analyt Serv & Mat Inc, Hampton, VA 23666 USA
[5] Univ Calif San Diego, Scripps Inst Oceanog, San Diego, CA USA
来源
关键词
D O I
10.1016/S0273-1177(02)80280-0
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
The CERES (Clouds and Earth Radiant Energy System) scanning radiometer has 3 channels: a shortwave channel for measuring solar radiation reflected from the Earth, a total channel, which combined with the shortwave channel gives the outgoing longwave radiation, and a channel for measuring radiances in the 8 to 12 mu window of the atmosphere. The CERES instrument aboard the Tropical Rainfall Measurement Mission (TRMM) spacecraft provided 8 months of data. This paper discusses the 8-12 mu channel of the CERES. In order to compute fluxes from radiance measurements, limb-darkening functions are required. These limb-darkening functions are also computed from CERES measurements and are then used to compute fluxes from the measured radiances. Finally, maps are examined to show features of radiation in the window channel. Published by Elsevier Science Ltd on behalf of COSPAR.
引用
收藏
页码:2377 / 2382
页数:6
相关论文
共 50 条
  • [31] New 8-12 conversion channel code and its application to high data-rate video recording
    Ishii, Hirotake
    Umemoto, Masuo
    Sawamura, Hidehiko
    Eto, Yoshizumi
    [J]. Electronics and Communications in Japan, Part II: Electronics (English translation of Denshi Tsushin Gakkai Ronbunshi), 1995, 78 (07): : 103 - 113
  • [32] Tuning the photoresponse of quantum dot infrared photodetectors across the 8-12 μm atmospheric window via rapid thermal annealing
    Aivaliotis, P.
    Zibik, E. A.
    Wilson, L. R.
    Cockburn, J. W.
    Hopkinson, M.
    Airey, R. J.
    [J]. APPLIED PHYSICS LETTERS, 2007, 91 (14)
  • [33] A NEW 8-12 CONVERSION CHANNEL CODE AND ITS APPLICATION TO HIGH DATA-RATE VIDEO RECORDING
    ISHII, H
    UMEMOTO, M
    SAWAMURA, H
    ETO, Y
    [J]. ELECTRONICS AND COMMUNICATIONS IN JAPAN PART II-ELECTRONICS, 1995, 78 (07): : 103 - 113
  • [34] Prematurity and reduced body fatness at 8-12 y of age
    Fewtrell, MS
    Lucas, A
    Cole, TJ
    Wells, JCK
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 2004, 80 (02): : 436 - 440
  • [35] FORAMINIFERA FROM DVDP HOLES 8-12, TAYLOR VALLEY
    WEBB, PN
    WRENN, JH
    [J]. ANTARCTIC JOURNAL OF THE UNITED STATES, 1976, 11 (02): : 85 - 86
  • [36] RADIATION OF CLOUDLESS AND CLOUDY ATMOSPHERES IN BAND 8-12 MUM
    BELICH, RB
    GORELIK, AG
    KALACHINSKII, SF
    NOVOKRESHCHENOVA, AS
    FROLOV, YA
    [J]. IZVESTIYA AKADEMII NAUK SSSR FIZIKA ATMOSFERY I OKEANA, 1976, 12 (01): : 29 - 37
  • [37] Dermatological conference in Paris - 8-12 December 2009 - Abstracts
    不详
    [J]. ANNALES DE DERMATOLOGIE ET DE VENEREOLOGIE, 2009, 136 : A53 - A332
  • [38] Spirituality, Religiousness, and Happiness in Children Aged 8-12 Years
    Holder, Mark D.
    Coleman, Ben
    Wallace, Judi M.
    [J]. JOURNAL OF HAPPINESS STUDIES, 2010, 11 (02) : 131 - 150
  • [39] Foam absorbing material properties in range of 8-12 GHZ
    Drobakhin, OO
    Kondrat'yev, YV
    Filinsky, LA
    [J]. IVTH INTERNATIONAL CONFERENCE ON ANTENNA THEORY AND TECHNIQUES, VOLS 1 AND 2, PROCEEDINGS, 2003, : 684 - 686
  • [40] Efficient 1 μm to 8-12 μm OPO converter
    Fukumoto, JM
    Fox, JA
    Swim, CR
    [J]. CHEMICAL AND BIOLOGICAL SENSING, 2000, 4036 : 196 - 199