Visualization of Failure and the Associated Grain-Scale Mechanical Behavior of Granular Soils under Shear using Synchrotron X-Ray Micro-Tomography

被引:3
|
作者
Cheng, Zhuang [1 ]
Wang, Jianfeng [1 ,2 ]
机构
[1] City Univ Hong Kong, Dept Architecture & Civil Engn, Hong Kong, Peoples R China
[2] City Univ Hong Kong, Shenzhen Res Inst, Shenzhen, Peoples R China
来源
基金
美国国家科学基金会;
关键词
Engineering; Issue; 151; granular soils; particle translation; particle rotation; strain localization; contact loss; contact gain; contact movement; triaxial compression; synchrotron X-ray micro-tomography; TRIAXIAL COMPRESSION; LOCALIZED DEFORMATION; ROLLING RESISTANCE; SAND; EVOLUTION; PARTICLES; DISCRETE; SHAPE; IMAGES; CT;
D O I
10.3791/60322
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The rapid development of X-ray imaging techniques with image processing and analysis skills has enabled the acquisition of CT images of granular soils with high-spatial resolutions. Based on such CT images, grain-scale mechanical behavior such as particle kinematics (i.e., particle translations and particle rotations), strain localization and inter-particle contact evolution of granular soils can be quantitatively investigated. However, this is inaccessible using conventional experimental methods. This study demonstrates the exploration of the grain-scale mechanical behavior of a granular soil sample under triaxial compression using synchrotron X-ray micro-tomography (mu CT). With this method, a specially fabricated miniature loading apparatus is used to apply confining and axial stresses to the sample during the triaxial test. The apparatus is fitted into a synchrotron X-ray tomography setup so that high-spatial resolution CT images of the sample can be collected at different loading stages of the test without any disturbance to the sample. With the capability of extracting information at the macro scale (e.g., sample boundary stresses and strains from the triaxial apparatus setup) and the grain scale (e.g., grain movements and contact interactions from the CT images), this procedure provides an effective methodology to investigate the multi-scale mechanics of granular soils.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Assessing failure in epitaxially encapsulated micro-scale sensors using micro and nano x-ray computed tomography
    Ortiz, Lizmarie Comenencia
    Heinz, David B.
    Flader, Ian B.
    Alter, Anne L.
    Shin, Dongsuk D.
    Chen, Yunhan
    Kenny, Thomas W.
    MRS COMMUNICATIONS, 2018, 8 (02) : 275 - 282
  • [42] Assessing failure in epitaxially encapsulated micro-scale sensors using micro and nano x-ray computed tomography
    Lizmarie Comenencia Ortiz
    David B. Heinz
    Ian B. Flader
    Anne L. Alter
    Dongsuk D. Shin
    Yunhan Chen
    Thomas W. Kenny
    W. Kenny Thomas
    MRS Communications, 2018, 8 : 275 - 282
  • [43] 3D-visualization and quantification of soil porous structure using X-ray micro-tomography scanning under native pasture and crop-livestock systems
    Dhaliwal, Jashanjeet K.
    Kumar, Sandeep
    SOIL & TILLAGE RESEARCH, 2022, 218
  • [44] Characterization of ductile damage for a high carbon steel using 3D X-ray micro-tomography and mechanical tests - Application to the identification of a shear modified GTN model
    Cao, T. -S.
    Maire, E.
    Verdu, C.
    Bobadilla, C.
    Lasne, P.
    Montmitonnet, P.
    Bouchard, P. -O.
    COMPUTATIONAL MATERIALS SCIENCE, 2014, 84 : 175 - 187
  • [45] Identification of strain fields in pure Al and hybrid Ni/Al metal foams using X-ray micro-tomography under loading
    Fila, T.
    Jirousek, O.
    Jung, A.
    Kumpova, I.
    JOURNAL OF INSTRUMENTATION, 2016, 11
  • [46] Shear fracture mechanism in micro-tension of an ultrafine-grained pure copper using synchrotron radiation X-ray tomography
    Li, Jianwei
    Xu, Jie
    Guo, Bin
    Shan, Debin
    Langdon, Terence G.
    SCRIPTA MATERIALIA, 2017, 132 : 25 - 29
  • [47] High-energy synchrotron-radiation-based X-ray micro-tomography enables non-destructive and micro-scale palaeohistological assessment of macro-scale fossil dinosaur bones
    Imai, Takuya
    Hattori, Soki
    Uesugi, Kentaro
    Hoshino, Masato
    JOURNAL OF SYNCHROTRON RADIATION, 2023, 30 (Pt 3) : 627 - 633
  • [48] Damage Kinetics at the Sub-micrometric Scale in Bast Fibers Using Finite Element Simulation and High-Resolution X-Ray Micro-Tomography
    Guessasma, Sofiane
    Beaugrand, Johnny
    FRONTIERS IN PLANT SCIENCE, 2019, 10
  • [49] Effect of Particle Breakage of Sand Under High Oedometric Stress on its Microstructural Properties Using 3D X-ray Micro-tomography
    Messioud, Seyf Eddine
    Dadda, Abdelali
    Feia, Sadok
    Elandaloussi, Radja
    Mabrouki, Abdelhak
    INDIAN GEOTECHNICAL JOURNAL, 2024, 54 (06) : 2379 - 2395
  • [50] Fibre failure assessment in carbon fibre reinforced polymers under tensile loading using in situ synchrotron X-ray computed tomography
    Rosini, Sebastian
    Mavrogordato, Mark N.
    Takano, Tsuneo
    Sugiura, Naoki
    Spearing, S. Mark
    Sinclair, Ian
    JOURNAL OF COMPOSITE MATERIALS, 2022, 56 (06) : 825 - 836