Elastic stent recoil in coronary total occlusions: Comparison of durable-polymer zotarolimus eluting stent and ultrathin strut bioabsorbable-polymer sirolimus eluting stent

被引:9
|
作者
Improta, Riccardo [1 ]
Scarparo, Paola [1 ]
Wilschut, Jeroen [1 ]
Wolff, Quinten [1 ]
Daemen, Joost [1 ]
Den Dekker, Wijnand K. [1 ]
Zijlstra, Felix [1 ]
Van Mieghem, Nicolas M. [1 ]
Diletti, Roberto [1 ]
机构
[1] Erasmus MC, Dept Intervent Cardiol, Thoraxctr, Rotterdam, Netherlands
关键词
percutaneous coronary intervention; CTO; quantitative coronary angiography; stent design; structure; coatings; stent; drug eluting; BALLOON ANGIOPLASTY; THIN STRUTS; ALL-COMERS; IMPACT; IMPLANTATION; DESIGN; RESTENOSIS; EFFICACY; OUTCOMES; LESIONS;
D O I
10.1002/ccd.29739
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives To compare stent recoil (SR) of the thin-strut durable-polymer Zotarolimus-eluting stent (dp-ZES) and the ultrathin-strut bioabsorbable-polymer Sirolimus-eluting stent (bp-SES) in chronic total occlusions (CTOs) and to investigate the predictors of high SR in CTOs. Background Newer ultrathin drug eluting stent might be associated with lower radial force and higher elastic recoil due to the thinner strut design, possibly impacting on the rate of in-stent restenosis and thrombosis. Methods Between January 2017 and November 2019, consecutive patients with CTOs undergoing percutaneous coronary intervention were evaluated. Only patients treated with dp-ZES or bp-SES were included and stratified accordingly. Quantitative coronary angiography analysis was used to assess absolute SR, relative SR, absolute focal SR, relative focal SR, high absolute, and high relative focal SR. Results A total of 128 lesions (67 treated with dp-ZES and 61 with bp-SES) in 123 patients were analyzed. Between bp-SES and dp-ZES no differences were found in absolute SR (p = .188), relative SR (p = .138), absolute focal SR (p = .069), and relative focal SR (p = .064). High absolute and high relative focal SR occurred more frequently in bp-SES than in dp-ZES (p = .004 and p = .015). Bp-SES was a predictor of high absolute focal SR (Odds ratio [OR] 3.29, 95% confidence interval [CI] 1.50-7.22, p = .003]. High-pressure postdilation and bp-SES were predictors of high relative focal SR (OR 2.22, 95% CI 1.01-4.86, p = .047; OR 2.74, 95% CI 1.24-6.02, p = .012, respectively). Conclusions Both stents showed an overall low SR. However, ultra-thin strut bp-SES was a predictor of high absolute and high relative focal SR.
引用
下载
收藏
页码:88 / 97
页数:10
相关论文
共 50 条
  • [21] SIROLIMUS: BIODEGRADABLE POLYMER DRUG ELUTING STENT VERSUS PERMANENT POLYMER DRUG ELUTING STENT
    Kumar, Karooa Aswinee
    Wang Hongyan
    Lou Dayuan
    Qu Peng
    HEART, 2012, 98 : E130 - E130
  • [22] Clinical outcome of biodegradable polymer sirolimus-eluting stent and durable polymer everolimus-eluting stent in patients with diabetes
    Kakizaki, Ryota
    Minami, Yoshiyasu
    Katamine, Masahiro
    Katsura, Aritomo
    Muramatsu, Yusuke
    Hashimoto, Takuya
    Meguro, Kentaro
    Shimohama, Takao
    Ako, Junya
    CARDIOVASCULAR DIABETOLOGY, 2020, 19 (01)
  • [23] Clinical outcome of biodegradable polymer sirolimus-eluting stent and durable polymer everolimus-eluting stent in patients with diabetes
    Ryota Kakizaki
    Yoshiyasu Minami
    Masahiro Katamine
    Aritomo Katsura
    Yusuke Muramatsu
    Takuya Hashimoto
    Kentaro Meguro
    Takao Shimohama
    Junya Ako
    Cardiovascular Diabetology, 19
  • [24] Randomized Comparison of a Biodegradable Polymer Ultrathin Strut Sirolimus-Eluting Stent With a Biodegradable Polymer Biolimus-Eluting Stent in Patients Treated With Percutaneous Coronary Intervention The SORT OUT VII Trial
    Jensen, Lisette Okkels
    Thayssen, Per
    Maeng, Michael
    Ravkilde, Jan
    Krusell, Lars Romer
    Raungaard, Bent
    Junker, Anders
    Terkelsen, Christian Juhl
    Veien, Karsten Tange
    Villadsen, Anton Boel
    Kaltoft, Anne
    Tilsted, Hans-Henrik
    Hansen, Knud Norregaard
    Aaroe, Jens
    Kristensen, Steen Dalby
    Hansen, Henrik Steen
    Jensen, Svend Eggert
    Madsen, Morten
    Botker, Hans Erik
    Berencsi, Klara
    Lassen, Jens Flensted
    Christiansen, Evald Hoj
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (07)
  • [25] Comparison the long-term clinical outcomes of Nano polymer-free sirolimus-eluting stent versus Endeavor durable polymer zotarolimus-eluting stent in patients with acute coronary syndrome
    文明洪
    刘松
    纪阳
    韩兆帅
    South China Journal of Cardiology, 2016, 17 (03) : 139 - 146
  • [26] THE COMPARISON OF CLINICAL OUTCOMES BETWEEN ZOTAROLIMUS-ELUTING STENT AND SIROLIMUS-ELUTING STENT FOR LONG CORONARY LESIONS
    Im, Eui
    Ko, Young-Guk
    Kim, Byeong-Keuk
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E1511 - E1511
  • [27] Biodegradable polymer-coated thin strut sirolimus-eluting stent versus durable polymer-coated everolimus-eluting stent in the diabetic population
    Gasior, Pawel
    Gierlotka, Marek
    Szczurek-Katanski, Krzysztof
    Osuch, Marcin
    Roleder, Magda
    Hawranek, Michal
    Wojakowski, Wojciech
    Polonski, Lech
    CARDIOLOGY JOURNAL, 2021, 28 (02) : 235 - 243
  • [28] Comparison of endothelial shear stress between ultrathin strut bioresorbable polymer drug-eluting stent vs durable-polymer drug-eluting stent post-stent implantation: An optical coherence tomography substudy from BIOFLOW II
    Beyene, Solomon
    Tufaro, Vincenzo
    Garg, Mohil
    Gkargkoulas, Fotis
    Calderon, Andrea Teira
    Safi, Hannah
    Waksman, Ron
    Windecker, Stephan
    Torii, Ryo
    Melaku, Gebremedhin D.
    Bulant, Carlos A.
    V. Bourantas, Christos
    Blanco, Pablo J.
    Garcia-Garcia, Hector M.
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2024, 61 : 26 - 34
  • [29] Ultrathin strut biodegradable polymer sirolimus-eluting stent versus durable polymer everolimus-eluting stent for percutaneous coronary revascularisation (BIOSCIENCE): a randomised, single-blind, non-inferiority trial
    Pilgrim, Thomas
    Heg, Dik
    Roffi, Marco
    Tuller, David
    Muller, Olivier
    Vuilliomenet, Andre
    Cook, Stephane
    Weilenmann, Daniel
    Kaiser, Christoph
    Jamshidi, Peiman
    Fahrni, Therese
    Moschovitis, Aris
    Noble, Stephane
    Eberli, Franz R.
    Wenaweser, Peter
    Juni, Peter
    Windecker, Stephan
    LANCET, 2014, 384 (9960): : 2111 - 2122
  • [30] Comparison of a Novel Biodegradable Polymer Sirolimus-Eluting Stent With a Durable Polymer Everolimus-Eluting Stent: A Systematic Review and Meta-Analysis
    Khalid, Yaser
    Dasu, Neethi
    Dasu, Kirti
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 76 (17) : B115 - B116