FPGA Acceleration for 3-D Low-Dose Tomographic Reconstruction

被引:3
|
作者
Zhang, Wentai [1 ]
Qiao, Linjun [2 ]
Hsu, William [3 ]
Cui, Yong [4 ]
Jiang, Ming [2 ]
Luo, Guojie [1 ]
机构
[1] Peking Univ, Ctr Energy Efficient Comp & Applicat, Beijing 100871, Peoples R China
[2] Peking Univ, Sch Math Sci, Dept Informat Sci, Beijing 100871, Peoples R China
[3] Univ Calif Los Angeles, Dept Radiol Sci, Los Angeles, CA 90095 USA
[4] Peking Univ Canc Hosp & Inst, Minist Educ, Dept Radiol, Key Lab Carcinogenesis & Translat Res, Beijing 100142, Peoples R China
基金
北京市自然科学基金; 中国国家自然科学基金;
关键词
Asynchronous parallelism; field-programmable gate array; iterative image reconstruction; low-dose computed tomography (CT); ITERATIVE RECONSTRUCTION; COMPUTED-TOMOGRAPHY; REDUCTION; CT; BACKPROJECTION; IMPLEMENTATION; SEGMENTATION; BASICS; CHEST;
D O I
10.1109/TCAD.2020.3006183
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
X-ray computed tomography (CT) is commonly used to obtain vivo images to characterize diseases but results in radiation exposure to patients. Low-dose CT (LDCT) provides CT images of clinical quality with reduced cumulative radiation dose. Iterative image reconstruction methods with effective regularization are used for LDCT but generally require more computing resources and induce higher computational load than the conventional filtered backprojection (FBP) methods. The high computational demand of the iterative reconstruction (IR) with notably increased reconstruction time precludes its routine clinical application. In this work, we focus on the FPGA acceleration of a compute-intensive full IR (full-IR) algorithm based on the Mumford-Shah regularization. At the algorithmic level, we propose a beam-based asynchronous update algorithm to reduce the computational cost and alleviate the conflicts. At the hardware-level, we first present pipeline-friendly optimization for the original algorithm to increase the computation throughput. We then apply the LDCT-specific tiling strategy to improve the data reuse rate. The experimental results show that our implementation takes 8.5 min to reconstruct a typical physical phantom with the image quality comparable with the vendor's result. The FPGA implementation achieves 11.6x throughput against the state-of-the-art GPU version.
引用
收藏
页码:666 / 679
页数:14
相关论文
共 50 条
  • [41] Image reconstruction by Mumford-Shah regularization for low-dose CT with multi-GPU acceleration
    Zhu, Yining
    Wang, Qian
    Li, Mengfei
    Jiang, Ming
    Zhang, Peng
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (15):
  • [42] A LOW-DOSE IPSILATERAL LUNG RESTRICTION IMPROVES 3-D CONFORMAL PLANNING FOR PARTIAL BREAST RADIATION THERAPY
    Mitchell, Tracy
    Truong, Pauline T.
    Salter, Lee
    Graham, Cathy
    Gaffney, Helene
    Beckham, Wayne
    Ouvotto, Ivo A.
    MEDICAL DOSIMETRY, 2011, 36 (01) : 10 - 13
  • [43] 3-D acceleration comes to LCDs
    Wright, M
    EDN, 1996, 41 (25) : 18 - 18
  • [44] 3-D Reconstruction System
    Cseri, O. E.
    Kerti, A.
    Vamossy, Z.
    2009 7TH INTERNATIONAL SYMPOSIUM ON INTELLIGENT SYSTEMS AND INFORMATICS, 2009, : 156 - 160
  • [45] AN INTERPOLATION TECHNIQUE FOR RECONSTRUCTION OF 3-D MEDICAL IMAGES FROM TOMOGRAPHIC CROSS-SECTIONS
    LIN, WC
    LIANG, CC
    CHEN, CT
    MEDICAL PHYSICS, 1987, 14 (03) : 494 - 494
  • [46] TOMOGRAPHIC RECONSTRUCTION OF 3-D VECTOR-FIELDS USING INNER-PRODUCT PROBES
    PRINCE, JL
    IEEE TRANSACTIONS ON IMAGE PROCESSING, 1994, 3 (02) : 216 - 219
  • [47] Combining a morphological interpolation approach with a surface reconstruction method for the 3-D representation of tomographic data
    Mouravliansky, N
    Matsopoulos, GK
    Delibasis, K
    Asvestas, P
    Nikita, KS
    JOURNAL OF VISUAL COMMUNICATION AND IMAGE REPRESENTATION, 2004, 15 (04) : 565 - 579
  • [48] Enhanced 3-D Reconstruction Method for Polarimetric Coherent Optimal-Based Tomographic SAR
    Dong, Shuhang
    Jiao, Zekun
    Zhou, Liangjiang
    Qiu, Xiaolan
    Yan, Qiancheng
    IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing, 2025, 18 : 5494 - 5508
  • [49] Low-Dose Conebeam CT Reconstruction Using Block-Matching 3D-Transform (BM3D) Regularization
    Lyu, Q.
    Yang, C.
    Gong, S.
    Xue, Y.
    Wang, J.
    O'Connor, D.
    Niu, T.
    Sheng, K.
    MEDICAL PHYSICS, 2017, 44 (06) : 3284 - 3284
  • [50] Combining Acceleration Techniques for Low-Dose X-Ray Cone Beam Computed Tomography Image Reconstruction
    Huang, Hsuan-Ming
    Hsiao, Ing-Tsung
    BIOMED RESEARCH INTERNATIONAL, 2017, 2017