Simple and rapid voltammetric determination of boron in water and steel samples using a pencil graphite electrode

被引:16
|
作者
Liv, Lokman [1 ]
Nakiboglu, Nuri [2 ]
机构
[1] TUBITAK UME, Natl Metrol Inst, Electrochem Lab, Chem Grp, Kocaeli, Turkey
[2] Balikesir Univ, Fac Arts & Sci, Dept Chem, Balikesir, Turkey
关键词
Pencil graphite electrode; boron; voltammetry; water; steel; PLASMA-MASS SPECTROMETRY; ATOMIC-ABSORPTION-SPECTROMETRY; ALIZARIN-RED-S; SPECTROFLUOROMETRIC DETERMINATION; ELECTROCHEMICAL DETERMINATION; STRIPPING VOLTAMMETRY; EMISSION-SPECTROMETRY; ESTER GENERATION; BERYLLON-III; TRACE BORON;
D O I
10.3906/kim-1507-64
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This paper presents a simple, rapid, and accurate voltammetric method for determination of boron in water and steel samples using a disposable pencil graphite electrode. The oxidation of Tiron in the boron Tiron complex in phosphate buffer at pH 7.5 was measured as a response. Type and concentration of supporting electrolyte, pH, ionic strength, Tiron concentration, scan rate, step amplitude, pulse amplitude, and pencil grade were investigated as the parameters affecting the peak current. The limit of detection (3s) was estimated as 84 mu g/L. The relative standard deviation of the method was 4.6 for 1 mg B/L (N = 7). The recovery results varied between 90% and 103% for water samples and between 94% and 108% for steel samples. The results were compared with those obtained from the ICP-OES method and no statistically significant difference between the methods was found.
引用
收藏
页码:412 / 421
页数:10
相关论文
共 50 条
  • [31] A voltammetric method for rapid determination of palladium in a phosphate electrolyte using a graphite electrode
    Kiryushov, VN
    Kletenik, YB
    INDUSTRIAL LABORATORY, 1997, 63 (02): : 63 - 65
  • [32] Rapid Voltammetric Screening Method for the Assessment of Bioflavonoid Content Using the Disposable Bare Pencil Graphite Electrode
    David, Iulia Gabriela
    Numan, Nimet
    Buleandra, Mihaela
    Popa, Dana-Elena
    Litescu, Simona Carmen
    Riga, Sorin
    Ciobanu, Adela Magdalena
    CHEMOSENSORS, 2021, 9 (11)
  • [33] Voltammetric determination of fenitrothion based on pencil graphite electrode modified with poly(Purpald®)
    Soysal, Mert
    CHEMICAL PAPERS, 2019, 73 (07): : 1785 - 1794
  • [34] Voltammetric determination of fenitrothion based on pencil graphite electrode modified with poly(Purpald®)
    Mert Soysal
    Chemical Papers, 2019, 73 : 1785 - 1794
  • [35] Novel Electrochemically Treated Graphite Pencil Electrode Surfaces for the Determination of Trace α-Naphthol in Water Samples
    Rana, Azeem
    Kawde, Abdel-Nasser
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2016, 63 (08) : 668 - 676
  • [36] Simple and rapid voltammetric determination of cephalosporin drug cefixime on boron-doped diamond electrode
    Keskin, Ertugrul
    Allahverdiyeva, Shabnam
    Seker, Hamza
    Yardim, Yavuz
    MONATSHEFTE FUR CHEMIE, 2019, 150 (11): : 1895 - 1902
  • [37] Simple and rapid voltammetric determination of cephalosporin drug cefixime on boron-doped diamond electrode
    Ertuğrul Keskin
    Shabnam Allahverdiyeva
    Hamza Seker
    Yavuz Yardım
    Monatshefte für Chemie - Chemical Monthly, 2019, 150 : 1895 - 1902
  • [38] Differential Pulse Voltammetric Determination of Folic Acid Using a Poly(Cystine) Modified Pencil Graphite Electrode
    Dokur, Ebrar
    Gorduk, Ozge
    Sahin, Yucel
    ANALYTICAL LETTERS, 2020, 53 (13) : 2060 - 2078
  • [39] Square wave anodic adsorptive stripping voltammetric determination of cefpodoxime proxetil by using pencil graphite electrode
    Erden, Sevcan
    MONATSHEFTE FUR CHEMIE, 2021, 152 (06): : 587 - 592
  • [40] Square wave anodic adsorptive stripping voltammetric determination of cefpodoxime proxetil by using pencil graphite electrode
    Sevcan Erden
    Monatshefte für Chemie - Chemical Monthly, 2021, 152 : 587 - 592