Simple and rapid voltammetric determination of boron in water and steel samples using a pencil graphite electrode

被引:16
|
作者
Liv, Lokman [1 ]
Nakiboglu, Nuri [2 ]
机构
[1] TUBITAK UME, Natl Metrol Inst, Electrochem Lab, Chem Grp, Kocaeli, Turkey
[2] Balikesir Univ, Fac Arts & Sci, Dept Chem, Balikesir, Turkey
关键词
Pencil graphite electrode; boron; voltammetry; water; steel; PLASMA-MASS SPECTROMETRY; ATOMIC-ABSORPTION-SPECTROMETRY; ALIZARIN-RED-S; SPECTROFLUOROMETRIC DETERMINATION; ELECTROCHEMICAL DETERMINATION; STRIPPING VOLTAMMETRY; EMISSION-SPECTROMETRY; ESTER GENERATION; BERYLLON-III; TRACE BORON;
D O I
10.3906/kim-1507-64
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This paper presents a simple, rapid, and accurate voltammetric method for determination of boron in water and steel samples using a disposable pencil graphite electrode. The oxidation of Tiron in the boron Tiron complex in phosphate buffer at pH 7.5 was measured as a response. Type and concentration of supporting electrolyte, pH, ionic strength, Tiron concentration, scan rate, step amplitude, pulse amplitude, and pencil grade were investigated as the parameters affecting the peak current. The limit of detection (3s) was estimated as 84 mu g/L. The relative standard deviation of the method was 4.6 for 1 mg B/L (N = 7). The recovery results varied between 90% and 103% for water samples and between 94% and 108% for steel samples. The results were compared with those obtained from the ICP-OES method and no statistically significant difference between the methods was found.
引用
收藏
页码:412 / 421
页数:10
相关论文
共 50 条
  • [1] Voltammetric Determination of Boron using Poly Xylenol Orange-Modified Pencil Graphite Electrode
    Liv, Lokman
    Nakiboglu, Nuri
    ANALYTICAL LETTERS, 2018, 51 (1-2) : 170 - 185
  • [2] Voltammetric Determination of Tannic Acid in Beverages using Pencil Graphite Electrode
    Vu, Dai Long
    Ertek, Bensu
    Dilgin, Yusuf
    Cervenka, Libor
    CZECH JOURNAL OF FOOD SCIENCES, 2015, 33 (01) : 72 - 76
  • [3] Voltammetric determination of diazepam using a bismuth modified pencil graphite electrode
    Dehghanzade, Mahsa
    Alipour, Esmaeel
    ANALYTICAL METHODS, 2016, 8 (09) : 1995 - 2004
  • [4] Voltammetric determination of rutin in fruit juice samples using a 2 mercaptobenzothiazole coated pencil graphite electrode
    En-Nakra, Farah
    Uzun, Demet
    Hasdemir, Erdogan
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2021, 104
  • [5] Voltammetric determination of famotidine on a disposable pencil graphite electrode
    David, Iulia Gabriela
    Popa, Dana Elena
    Calin, Andreea-Alexandra
    Buleandra, Mihaela
    Iorgulescu, Emilia-Elena
    TURKISH JOURNAL OF CHEMISTRY, 2016, 40 (01) : 125 - 135
  • [6] Development of a voltammetric method for the determination of rapamycin in pharmaceutical samples at pretreated pencil graphite electrode
    Karaboduk, Kuddusi
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2021, 68 (09) : 1722 - 1730
  • [7] SIMPLE VOLTAMMETRIC ANALYSIS OF SULFAMETHOXAZOLE AT A DISPOSABLE PENCIL GRAPHITE ELECTRODE
    David, Iulia Gabriela
    Panait, Andreea Laura
    Buleandra, Mihaela
    Popa, Dana Elena
    Cheregi, Mihaela C.
    REVUE ROUMAINE DE CHIMIE, 2022, 67 (03) : 177 - 183
  • [8] Voltammetric Determination of Pyridoxine in Pharmaceutical Samples Using Phosphorus-Doped Copper Oxide Pencil Graphite Electrode
    Acikalin, Merve Yalcin
    Dokur, Ebrar
    Uruc, Selen
    Gorduk, Ozge
    Sahin, Yucel
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2024, 171 (11)
  • [9] A disposable voltammetric sensor for the determination of diphenylamine using modified pencil graphite electrode
    Santhy Antherjanam
    Beena Saraswathyamma
    Analytical Sciences, 2024, 40 : 163 - 174
  • [10] Voltammetric determination of erythromycin in water samples using a boron-doped diamond electrode
    Radicova, Monika
    Behul, Miroslav
    Vojs, Marian
    Bodor, Robert
    Stanova, Andrea Vojs
    PHYSICA STATUS SOLIDI B-BASIC SOLID STATE PHYSICS, 2015, 252 (11): : 2608 - 2613