Transient state tests of cold-formed stainless steel single shear bolted connections

被引:22
|
作者
Cai, Yancheng [1 ]
Young, Ben [1 ]
机构
[1] Univ Hong Kong, Dept Civil Engn, Hong Kong, Hong Kong, Peoples R China
关键词
Experimental investigation; Failure modes; Material properties; Single shear bolted connection; Stainless steel; Ultimate strength; Transient state test; THIN SHEET STEELS; ELEVATED-TEMPERATURES; SCREWED CONNECTIONS; BEHAVIOR; RESISTANCE; DESIGN;
D O I
10.1016/j.engstruct.2014.09.031
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A total of 87 cold-formed stainless steel single shear bolted connections was conducted. The specimens were tested using transient state test method. The single shear bolted connection specimens were fabricated by three different grades of stainless steel. The three different grades of stainless steel are austenitic stainless steel EN 1.4301 (AISI 304) and EN 1.4571 (AISI 316Ti having small amount of titanium) as well as lean duplex stainless steel EN 1.4162 (AISI S32101). Three different load levels of 0.25, 0.50 and 0.75 of the failure load at room temperature were investigated. The tendency of the test strength reduction of the stainless steel single shear bolted connections conducted using the transient state test method is similar to those results obtained by the steady state test method. However, the critical temperatures determined by the transient state test results are usually slightly higher compared with those deduced from the steady state test results at the load levels of 0.25 and 0.50 of the failure load at room temperature. The austenitic stainless steel grade EN 1.4571 (AISI 316Ti) generally has better resistance than the other two stainless steel grades in transient state tests as higher values of critical temperatures were obtained. Two main failure modes, namely the bearing and net section tension failures, were observed in the transient state tests. The failure modes of the specimens in transient state tests at the load level of 0.25 are generally consistent with those specimens in the steady state tests. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
  • [31] Seismic Behavior of Cold-Formed Steel Frames with Bolted Moment Connections
    Chen, Ming
    Huo, Jia-Hao
    Xing, Yi-Wen
    JOURNAL OF STRUCTURAL ENGINEERING, 2020, 146 (03)
  • [32] Tensile Tests of Cold-Formed Stainless Steel Tubes
    Chen, Man-Tai
    Young, Ben
    JOURNAL OF STRUCTURAL ENGINEERING, 2020, 146 (09)
  • [33] Tests on cold-formed and welded stainless steel members
    Talja, A
    LIGHT-WEIGHT STEEL AND ALUMINIUM STRUCTURES, 1999, : 531 - 538
  • [34] Push-out tests on bolted shear connectors in composite cold-formed steel beams
    Hosseinpour, Mahmoud
    Zeynalian, Mehran
    Ataei, Abdoreza
    Daei, Maryam
    THIN-WALLED STRUCTURES, 2021, 164
  • [35] CONNECTIONS IN COLD-FORMED STEEL
    TOMA, A
    SEDLACEK, G
    WEYNAND, K
    THIN-WALLED STRUCTURES, 1993, 16 (1-4) : 219 - 237
  • [36] Shaketable tests of a cold-formed steel shear panel
    Kim, Tae-Wan
    Wilcoski, James
    Foutch, Douglas A.
    Lee, Moon Sung
    ENGINEERING STRUCTURES, 2006, 28 (10) : 1462 - 1470
  • [37] Block shear behaviour and design of cold-formed staggered hole bolted connections
    Pham, Viet Binh
    Pham, Cao Hung
    Hancock, Gregory J.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 180
  • [38] Fire resistance of stainless steel single shear bolted connections
    Cai, Yancheng
    Young, Ben
    THIN-WALLED STRUCTURES, 2018, 130 : 332 - 346
  • [39] Lap shear tests of bolted and screwed ferritic stainless steel connections
    Talja, Asko
    Torkar, Matjaz
    THIN-WALLED STRUCTURES, 2014, 83 : 157 - 168
  • [40] Bolted Connections in Cold-Formed Steel: Reliability Analysis for Rupture in Net Section
    Bolandim, Emerson A.
    Beck, Andre T.
    Malite, Maximiliano
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2013, 139 (05): : 748 - 756