Percutaneous atlantoaxial anterior transarticular screw fixation combined with mini-open posterior C1/2 wire fusion for patients with a high-riding vertebral artery

被引:10
|
作者
Wu, Ai-Min [1 ]
Wang, Xiang-Yang [1 ]
Zhou, Feng [1 ]
Zhang, Xiao-Lei [1 ]
Xu, Hua-Zi [1 ]
Chi, Yong-Long [1 ]
机构
[1] Wenzhou Med Univ, Affiliated Hosp 2, Dept Spinal Surg, Zhejiang Spine Ctr, Wenzhou, Zhejiang, Peoples R China
来源
JOURNAL OF SPINAL CORD MEDICINE | 2016年 / 39卷 / 02期
基金
中国国家自然科学基金;
关键词
Percutaneous; Minimally invasive; Anterior transarticular screw fixation; High-riding vertebral artery; Gallie fusion; BIOMECHANICAL ANALYSIS; C1-C2; FUSION; INSTABILITY; INJURY; STABILIZATION; ARTHRODESIS; SURGERY;
D O I
10.1179/2045772314Y.0000000298
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Context/objective: To describe the technique and clinical results of percutaneous atlantoaxial anterior transarticular fixation combined with limited exposure posterior C1/2 arthrodesis in patients with a high-riding vertebral artery. Design setting: Zhejiang Spine Center, China. Participants: Five patients with a high-riding vertebral artery and an upper cervical fracture. Interventions: Percutaneous atlantoaxial anterior transarticular screw fixation combined with limited exposure posterior C1/2 wire fusion. Outcome measures: Computed tomography scans were used to assess the high-riding vertebral artery and feasibility of anterior transarticular screw fixation preoperatively. A Philadelphia collar was used to immobilize the neck postoperatively. Anteroposterior (open-mouth) and lateral views were obtained at pre/postoperation and at the follow-up. Results: The operation was performed successfully on all of the patients, and no intraoperative operation-related complications such as nerve injury, vertebral artery, and soft tissue complications occurred. The mean follow-up period was 33.8 months (range: 24 to 58 months). No screw breakage, loosening, pullout, or cutout was observed. Bone union was achieved in all patients at the last follow-up. Conclusions: Our small case series results suggested that percutaneous anterior transarticular screw fixation combined with mini-open posterior C1/2 wire fusion is a technically minimally invasive, safe, feasible, and useful method to treat patients with a high-riding vertebral artery.
引用
收藏
页码:234 / 239
页数:6
相关论文
共 44 条
  • [41] Transarticular screw fixation C1/C2 in traumatic atlantoaxial instabilities. Comparison between percutaneous and open proceduresTransartikuläre Verschraubung C1/C2 bei atlanto-axialer Instabilität. Vergleich zwischen perkutanem und offenen Vorgehen
    M. Blauth
    M. Richter
    U. Lange
    Der Orthopäde, 1999, 28 : 651 - 661
  • [42] Is Initial Posterior Atlantoaxial Fixation and Fusion Applying Bilateral C1-2 Transarticular Screws and C1 Laminar Hooks Reliable for Acute Pediatric Atlantoaxial Instability? A Minimal 10-Year Analysis of Outcome and Radiological Evaluation
    Guo, Xiang
    Han, Zhao
    Chen, Qunxiang
    Yang, Jun
    Chen, Fei
    Guo, Qunfeng
    Lin, Peida
    Ni, Bin
    SPINE, 2020, 45 (04) : 244 - 249
  • [43] Ideal entry point and trajectory for C2 pedicle screw placement in basilar invagination patients with high-riding vertebral artery based on 3D computed tomography
    Zhou, Lu-Ping
    Zhang, Ren-Jie
    Jiang, Zhen-Fei
    Tao, Er-Xu
    Shang, Jin
    Shen, Cai-Liang
    SPINE JOURNAL, 2022, 22 (08): : 1281 - 1291
  • [44] Biomechanical study of novel unilateral C1 posterior arch screws and C2 laminar screws combined with an ipsilateral crossed C1-C2 pedicle screw-rod fixation for atlantoaxial instability
    Shen, Kai
    Deng, Zhongliang
    Yang, Junsong
    Liu, Chao
    Zhang, Ranxi
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2017, 137 (10) : 1349 - 1355