CT-guided percutaneous biopsy of suspect pancreatic lesions: radiological and clinical outcome

被引:5
|
作者
Gruber-Rouh, T. [1 ]
Langenbach, M. C. [1 ]
Eichler, K. [1 ]
Vogl, T. J. [1 ]
Yel, I [1 ]
Beeres, M. [1 ]
机构
[1] Univ Hosp Frankfurt, Inst Diagnost & Intervent Radiol, D-60590 Frankfurt, Germany
关键词
CORE-NEEDLE-BIOPSY; CANCER; DIAGNOSIS; MASSES;
D O I
10.1016/j.crad.2019.07.022
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To evaluate the clinical utility of computed tomography (CT)-guided percutaneous biopsies of suspect pancreatic lesions regarding safety, efficiency, radiation dose, intervention time, diagnostic yield, and complications. MATERIALS AND METHODS: Between 2015 and 2018, 48 patients (18 female, 30 male; mean age: 64.2 years) with suspect pancreatic lesions underwent CT-guided percutaneous biopsy. Ultrasound-guided biopsy of all lesions was not possible or without any result. CT-guided interventions were compared according to the following intervention parameters: radiation dose, procedure duration, number of needle correction scans. Evaluation criteria included technical success as well as major and minor complications according to the Society of Interventional Radiology. RESULTS: Biopsies were performed successfully in 100% of patients. No major side effects occurred during intervention. As a minor complication, 29.2% showed focal haemorrhage. Seventy-seven percent of lesions had a malignant appearance, and benign inflammatory lesions were found in 23%. The mean size of the target lesions was 2.9 cm (range: 0.7-2.3 cm). The mean target access path within the patient was 8 cm (range: 3-14 cm). The duration to completion was 12 minutes (range: 3 minutes 30 seconds to 30 minutes). The dose-length product of the intervention was 89.5 mGy.cm (range: 11-350 mGy.cm). The average number needle correction scans was 31.1 (range: 6-36). CONCLUSION: CT-guided biopsy of suspect pancreatic lesions is an efficient and safe method. It can be performed within short intervention times and low radiation exposure for differentiation of unclear lesions. (C) 2019 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:899.e7 / 899.e12
页数:6
相关论文
共 50 条
  • [31] CT-GUIDED PERCUTANEOUS LUNG BIOPSY AND CLINICAL VALUE OF SECURITY ANALYSIS
    Meng, C.
    RESPIROLOGY, 2011, 16 : 48 - 48
  • [32] Predicting the occurrence of pulmonary haemorrhage complicating percutaneous CT-guided lung biopsy: A study of clinical and radiological variables
    Chakrabarti, B.
    McCann, C.
    Amin, S.
    Pandey, R.
    Jones, P. L.
    Thwaite, E.
    Earis, J. E.
    Curtis, J. M.
    Warburton, C. J.
    THORAX, 2006, 61 : II104 - II104
  • [33] Clinical value of an electromagnetic navigation system for CT-guided percutaneous lung biopsy of peripheral lung lesions
    Zhang, Yao
    Huang, Haozhe
    Cao, Shuhui
    Teng, Jiajun
    Wang, Yue
    Ling, Xuxinyi
    Zhou, Yan
    Xu, Jianlin
    Li, Wentao
    Zhong, Hua
    JOURNAL OF THORACIC DISEASE, 2021, 13 (08) : 4885 - 4893
  • [34] Revisiting CT-Guided Percutaneous Core Needle Biopsy of Musculoskeletal Lesions: Contributors to Biopsy Success
    Omura, Michelle C.
    Motamedi, Kambiz
    UyBico, Stacy
    Nelson, Scott D.
    Seeger, Leanne L.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (02) : 457 - 461
  • [35] CT-guided biopsy or aspiration of bone lesions
    Harari, J
    COMPENDIUM ON CONTINUING EDUCATION FOR THE PRACTICING VETERINARIAN, 2005, 27 (08): : 576 - +
  • [36] CT-guided needle biopsy for musculoskeletal lesions
    Satoshi Tsukushi
    Yoshihiro Nishida
    Yoshihisa Yamada
    Masahiro Yoshida
    Naoki Ishiguro
    Archives of Orthopaedic and Trauma Surgery, 2010, 130 : 699 - 703
  • [37] CT-guided needle biopsy for musculoskeletal lesions
    Tsukushi, Satoshi
    Nishida, Yoshihiro
    Yamada, Yoshihisa
    Yoshida, Masahiro
    Ishiguro, Naoki
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2010, 130 (05) : 699 - 703
  • [38] PET/CT-guided biopsy of liver lesions
    Cerci J.J.
    Huber F.Z.T.
    Bogoni M.
    Clinical and Translational Imaging, 2014, 2 (2) : 157 - 163
  • [39] CT-GUIDED BIOPSY OF SPINE LYTIC LESIONS
    FACCHINETTI, A
    GRIVETTA, MA
    BARUZZI, F
    MINONZIO, G
    MERCURI, A
    ALBERTINI, F
    BONALDI, G
    RIVISTA DI NEURORADIOLOGIA, 1995, 8 (02): : 215 - 221
  • [40] Accuracy of CT-guided percutaneous core needle biopsy for assessment of pediatric musculoskeletal lesions
    Anastasia L. Hryhorczuk
    Peter J. Strouse
    J. Sybil Biermann
    Pediatric Radiology, 2011, 41 : 848 - 857