Study of bubble damage detectors for neutron detection

被引:4
|
作者
Tu, CQ [1 ]
Guo, SL [1 ]
Wang, YL [1 ]
Hao, XH [1 ]
Chen, CM [1 ]
Su, JL [1 ]
机构
[1] Inst Atom Energy, Beijing 102413, Peoples R China
关键词
bubble damage detector; neutron detection; superheated liquid droplets; polymer; neutron dosimeter;
D O I
10.1016/S1350-4487(97)00059-0
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Bubble damage detectors have been prepared by using polyacrylamide as detector solid and freon as detector liquid. Tests show that the prepared detectors are sensitive to fast neutrons and have proportionality between bubble number and neutron fluence within a certain range of neutron fluence. Therefore, it can be used as a fast neutron detector and a dosimeter. Our experiments also show that the sensitivity of the detector increases with temperature.
引用
收藏
页码:159 / 162
页数:4
相关论文
共 50 条
  • [12] Preliminary Study on Application of Neutron Bubble Detectors as Personal Neutron Dosimeters in Nuclear Well Logging
    Zhang, Guiying
    Deng, Jun
    Cao, Lei
    Zhang, Haiqing
    Ni, Bangfa
    Tian, Weizhi
    Wang, Pingsheng
    Huang, Donghui
    Liu, Cunxiong
    Xiao, Caijin
    Zhao, Changjun
    HEALTH PHYSICS, 2011, 100 (02): : S30 - S34
  • [13] Fast neutron damage in silicon detectors
    Kraner, H.W., 1600, (279): : 1 - 2
  • [14] ACOUSTIC DETECTION OF NEUTRONS BY BUBBLE DETECTORS
    BIRO, T
    KELEMEN, A
    PAVLICSEK, I
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1990, 17 (04): : 587 - 589
  • [15] Longevity tests and background response of bubble neutron detectors
    Sawicki, J.A.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1993, A336 (1-2) : 215 - 219
  • [16] LONGEVITY TESTS AND BACKGROUND RESPONSE OF BUBBLE NEUTRON DETECTORS
    SAWICKI, JA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 336 (1-2): : 215 - 219
  • [17] ACTIVE NEUTRON SPECTROMETRY WITH SUPERHEATED DROP (BUBBLE) DETECTORS
    DERRICO, F
    ALBERTS, WG
    CURZIO, G
    GULDBAKKE, S
    KLUGE, H
    MATZKE, M
    RADIATION PROTECTION DOSIMETRY, 1995, 61 (1-3) : 159 - 162
  • [18] Neutron measurements using bubble detectors - terrestrial and space
    Ing, H
    RADIATION MEASUREMENTS, 2001, 33 (03) : 275 - 286
  • [19] Neutron ambient dosimetry with superheated drop (bubble) detectors
    dErrico, F
    Alberts, WG
    Dietz, E
    Gualdrini, G
    Kurkdjian, J
    Noccioni, P
    Siebert, BRL
    RADIATION PROTECTION DOSIMETRY, 1996, 65 (1-4) : 397 - 400
  • [20] NEUTRON DETECTION WITH HYDROGENOUS DETECTORS
    KRAMERAGEEV, EA
    PARKHOMOV, AG
    TROSHIN, VS
    SHUBTSOV, MI
    SOVIET ATOMIC ENERGY, 1976, 41 (03): : 837 - 837