Purpose: This study analyzes the results of image‐guided prostate photodynamic therapy (PDT) that integrates PDT dosimetry, light source optimization, computerized light power adjustment, and volumetric real‐time light fluence calculation to deliver uniform photodynamic dose to the target volume (prostate) and spares the critical structures (rectum and bladder). Methods and Materials: All procedures are under the image guidance of transrectal ultrasound. The PDT dosimetry includes multi‐channel real‐time in‐vivo light dosimetry, absorption and fluorescence spectroscopy for 3D optical properties, drug concentrations, and tissue oxygenation. Drug concentration is also determined using fluorescence from a single optical fiber. These measurements are made before and after motexafin lutetium (MLu)‐mediated photodynamic therapy (PDT) using a computerized step motor. The light fluence rate distributions are also measured along the catheters during PDT and compared to the 3D volumetric light fluence calculations. Real‐time light fluence calculation was performed on the 3D target volumes using ultrasound image guidance. An optimization algorithm determines the light source strength, lengths, location, and retraction for cylindrical diffusing fibers (CDF) based on the 3D heterogeneous optical properties. The resulting light source power is feedback into a 12‐channel beamsplitter that is connected to a motorized attenuator system to control the light source intensity interactively during PDT. Results: Preliminary data have shown widespread heterogeneities of optical properties and photosensitizing drug distribution. As a result of these heterogeneities, methods to quantifying the three‐dimensional (3D) distributions of these quantities in individual prostate are essential for the successful application of PDT. Comparison of light fluence rate between real‐time measurements and calculation is performed in heterogeneous medium and the standard deviations are within 30% with a simplified model and better than 11% for an improved model. Conclusions: We have shown the rational and potential for an integrated system that is capable of obtaining critical parameters (light, drug, and oxygenation) and using the PDT dosimetry result as feedback to optimize treatment delivery. We concluded that a real‐time dosimetry and feedback system for monitoring PDT dose during treatment is both achievable and required for clinical interstitial PDT applications. Educational Objectives: 1. To explain the basic principle of PDT dosimetry. 2. To review explicit PDT dosimetry techniques to characterize tissue optical properties, drug concentration, tissue oxygen concentration, and PDT efficacy. 3. To discuss the rational and requirement for a feedback system incorporating PDT dosimetry, PDT dose optimization, and computerized light delivery. 4. Summarize the clinical results of Prostate PDT. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2588 / 2588
页数:1
相关论文
共 50 条
  • [21] Acute toxicity of image-guided hypofractionated proton therapy for localized prostate cancer
    Koichiro Nakajima
    Hiromitsu Iwata
    Hiroyuki Ogino
    Yukiko Hattori
    Shingo Hashimoto
    Mikiko Nakanishi
    Toshiyuki Toshito
    Yukihiro Umemoto
    Shoichiro Iwatsuki
    Yuta Shibamoto
    Jun-etsu Mizoe
    International Journal of Clinical Oncology, 2018, 23 : 353 - 360
  • [22] Optimized image-guided radiation therapy protocol for the prostate
    Jenkins, T.
    Sibata, C.
    Wolfe, M.
    Patel, R.
    Mota, H.
    Bonnerup, C.
    Arastu, H.
    Allison, R.
    EJC SUPPLEMENTS, 2005, 3 (02): : 235 - 235
  • [23] Gold nanoparticles in image-guided cancer therapy
    Kim, Dongkyu
    Jon, Sangyong
    INORGANICA CHIMICA ACTA, 2012, 393 : 154 - 164
  • [24] Image-guided enzyme/prodrug cancer therapy
    Li, Cong
    Penet, Marie-France
    Winnard, Paul, Jr.
    Artemov, Dmitri
    Bhujwalla, Zaver M.
    CLINICAL CANCER RESEARCH, 2008, 14 (02) : 515 - 522
  • [25] Image-Guided Nanodrug Therapy in Breast Cancer
    不详
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (11) : 21N - 22N
  • [26] Comparison of Image-guided Radiotherapy Technologies for Prostate Cancer
    Das, Satya
    Liu, Tian
    Jani, Ashesh B.
    Rossi, Peter
    Shelton, Joseph
    Shi, Zheng
    Khan, Mohammad K.
    AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2014, 37 (06): : 616 - 623
  • [27] Image-guided radiotherapy in prostate cancer: Concepts and implications
    Crehange, G.
    Martin, E.
    Supiot, S.
    Chapet, O.
    Mazoyer, F.
    Naudy, S.
    Maingon, P.
    CANCER RADIOTHERAPIE, 2012, 16 (5-6): : 430 - 438
  • [28] Image-guided adaptive therapy for lung cancer
    Ramsey, C
    Mahan, S
    MEDICAL PHYSICS, 2005, 32 (06) : 2125 - 2125
  • [29] Image-guided Prostate biopsy
    Hadaschik, B.
    AKTUELLE UROLOGIE, 2012, 43 (05) : 279 - 280
  • [30] Image-Guided Volumetric Modulated Arc Therapy (IG-VMAT) For Prostate Cancer
    Song, Yulin
    Mueller, Boris
    Obcemea, Ceferino
    Mychalczak, Borys
    5TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, PTS 1 AND 2, 2012, 37 : 223 - +