Detection of the fast neuronal signal on the motor cortex using functional frequency domain near infrared spectroscopy

被引:0
|
作者
Wolf, M [1 ]
Wolf, U [1 ]
Choi, JH [1 ]
Gupta, R [1 ]
Safonova, LP [1 ]
Paunescu, LA [1 ]
Michalos, A [1 ]
Gratton, E [1 ]
机构
[1] Univ Illinois, Dept Phys, Martin Wolf Lab Fluorescence Dynam, Urbana, IL 61801 USA
关键词
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Using non-invasive near infrared spectroscopy fast changes in the range of ms in the optical properties of neurons during brain activity have been described. Since the signal is small, the system to detect it has to be highly noise optimized. We used a frequency-domain tissue oximeter, whose laser diodes were modulated at 110MHz and the amplitude (AC), mean intensity (DC) and phase (phi) of the modulated optical signal was measured at 96 Hz sample rate. In two volunteers, 36 and 37 years old, the probe consisting of 4 crossed source detector pairs was placed above the motor cortex (C3 position), contralateral to the hand performing the tapping exercise. The tapping frequency was set at 2.5 times the heart rate of the subject to avoid the influence of harmonics on the signal. An electronic device recorded the tapping movement. Control-data were obtained from a solid medium of approximately the same optical properties as the human head. To reduce physiological noise the arterial pulsatility was removed using an adaptive filter, the data was detrended by a high pass filter and a cross correlation function between the optical data and the tapping signal was calculated. The instrumental noise of the control data was very low (AC mean 0.0015% +/- SD 0.00092%, DC 0.00037% +/- 0.00023% and phi 0.00083degrees +/- 0.00042degrees). On the head the noise level was AC 0.0042% +/- 0.0031%, DC 0.0021% +/- 0.0012% and phi 0.0020degrees +/- 0.0017degrees. In 14 DC, 5 AC and 0 phi out of 30 locations a fast signal was detected, which was higher (p<0.001) than the noise level. This signal disappeared during non-tapping periods. With the signal to noise ratio that we have achieved single subject measurements become feasible.
引用
收藏
页码:193 / 197
页数:5
相关论文
共 50 条
  • [41] A New Signal Analysis Method for Functional Near-Infrared Spectroscopy
    Zhang Zhongpeng
    Hong Wenxue
    PROCEEDINGS OF 2016 8TH IEEE INTERNATIONAL CONFERENCE ON COMMUNICATION SOFTWARE AND NETWORKS (ICCSN 2016), 2016, : 100 - 106
  • [42] Cortical Signal Analysis and Advances in Functional Near-Infrared Spectroscopy Signal: A Review
    Kamran, Muhammad A.
    Mannan, Malik M. Naeem
    Jeong, Myung Yung
    FRONTIERS IN HUMAN NEUROSCIENCE, 2016, 10
  • [43] Investigation of Neuromodulatory Effect of Anodal Cerebellar Transcranial Direct Current Stimulation on the Primary Motor Cortex Using Functional Near-Infrared Spectroscopy
    Shoaib, Zeshan
    Chang, Won Kee
    Lee, Jongseung
    Lee, Stephanie Hyeyoung
    Phillips, V. Zephaniah
    Lee, Seung Hyun
    Paik, Nam-Jong
    Hwang, Han-Jeong
    Kim, Won-Seok
    CEREBELLUM, 2024, 23 (01): : 56 - 66
  • [44] Investigation of Neuromodulatory Effect of Anodal Cerebellar Transcranial Direct Current Stimulation on the Primary Motor Cortex Using Functional Near-Infrared Spectroscopy
    Zeshan Shoaib
    Won Kee Chang
    Jongseung Lee
    Stephanie Hyeyoung Lee
    Zephaniah Phillips V
    Seung Hyun Lee
    Nam-Jong Paik
    Han-Jeong Hwang
    Won-Seok Kim
    The Cerebellum, 2024, 23 : 56 - 66
  • [45] Spontaneous Lie Detection using Functional Near-infrared Spectroscopy in an Interactive Game
    Bhutta, M. Raheel
    Hong, Keum-Shik
    Naseer, Noman
    Khan, M. Jawad
    2015 10TH ASIAN CONTROL CONFERENCE (ASCC), 2015,
  • [46] Noninvasive detection of fast signals from the cortex using frequency-domain optical methods
    Gratton, G
    Fabiani, M
    Corballis, PM
    Gratton, E
    IMAGING BRAIN STRUCTURE AND FUNCTION: EMERGING TECHNOLOGIES IN THE NEUROSCIENCES, 1997, 820 : 286 - 299
  • [47] Vigilance Detection Based on Functional Near-Infrared Spectroscopy
    Cao Yong
    Jiao Xunjun
    Jiang Jin
    Fu Jiahao
    Pan Jinjin
    ACTA OPTICA SINICA, 2018, 38 (03)
  • [48] Mental Fatigue Detection Based on the Functional Near Infrared Spectroscopy
    Zhang, Zhen
    Xu, Fenggang
    Yang, Hanjun
    Jiang, Jin
    Cao, Yong
    Jiao, Xuejun
    INTERNATIONAL CONFERENCE ON OPTICAL AND PHOTONICS ENGINEERING (ICOPEN 2016), 2017, 10250
  • [49] Region of interest detection and evaluation in functional near infrared spectroscopy
    Rojas, Raul Fernandez
    Huang, Xu
    Ou, Keng-Liang
    JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2016, 24 (04) : 317 - 326
  • [50] Exploring prefrontal cortex oxygenation in schizophrenia by functional near-infrared spectroscopy
    Quaresima, Valentina
    Giosue, Patricia
    Roncone, Rita
    Casacchia, Massimo
    Ferrari, Marco
    OXYGEN TRANSPORT TO TISSUE XXVII, 2006, 578 : 229 - 235