Feasibility of using intravenous contrast-enhanced computed tomography (CT) scans in lung cancer treatment planning

被引:24
|
作者
Xiao, Jianghong [1 ]
Zhang, Hong [2 ]
Gong, Youling [3 ,4 ]
Fu, Yuchuan [1 ,3 ]
Tang, Bin [1 ]
Wang, Shichao [1 ]
Jiang, Qingfeng [1 ]
Li, Ping [2 ,3 ]
机构
[1] Sichuan Univ, W China Hosp, Radiat Phys Ctr, Chengdu 610041, Sichuan Prov, Peoples R China
[2] Sichuan Univ, W China Hosp, Dept Radiat Oncol, Chengdu 610041, Sichuan Prov, Peoples R China
[3] Sichuan Univ, W China Hosp, State Key Lab Biotherapy, Chengdu 610041, Sichuan Prov, Peoples R China
[4] Sichuan Univ, W China Hosp, Dept Thorac Oncol, Chengdu 610041, Sichuan Prov, Peoples R China
关键词
Contrast agent; Active breathing control; Treatment planning; Dose calculation; Lung cancer; BREATHING CONTROL ABC; CONFORMAL RADIOTHERAPY; DOSE CALCULATIONS; MONTE-CARLO; REPRODUCIBILITY; COMPUTATIONS; ACCURACY;
D O I
10.1016/j.radonc.2010.02.029
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: To investigate the feasibility of using intravenous contrast-enhanced computed tomography (CT) scans in 3-dimensional conformal radiotherapy (3D-CRT), stereotactic body radiation therapy (SBRT) and intensity-modulated radiotherapy (IMRT) treatment planning for lung cancers, respectively. Materials and methods: Twelve patients with bulky lung tumors and 14 patients with small lung tumors were retrospectively analyzed. Each patient took two sets of CT in the same position with active breathing control (ABC) technique before and after intravenous contrast agent (CA) injections. Bulky tumors were planned with 3D-CRT, while SBRT plans were generated for patients with small tumors based on CT scans with intravenous CA. In addition, IMRT plans were generated for patients with bulky tumors to continue on a planning study. All plans were copied and replaced on the scans without intravenous CA. The radiation doses calculated from the two sets of CTs were compared with regard to planning volumes (PTV), the organ at-risk (OAR) and the lungs using Wilcoxon's signed rank test. Results: In comparisons for 3D-CRT plans, CT scans with intravenous CA reduced the mean dose and the maximum dose of PTV with significant differences (p < 0.05) that were within 1.0%. Comparing IMRT and SBRT plans, CT scans with intravenous CA obviously increased the minimum irradiation dose and dose of 95% volume of target received (D(95)) for targets, respectively (p < 0.05). There was no statistical significance for lung parameters between two sets of scans in SBRT plans and IMRT plans. Conclusions: The enhanced CT scans can be used for both target delineation and treatment planning in 3D-CRT. The dose difference caused by intravenous CA is small. But for SBRT and IMRT, the minimum irradiation dose in targets may be estimated to be increased up to 2.71% while the maximum dose may be estimated to be decreased up to 1.36%. However, the difference in dose distribution in most cases were found to be clinical tolerable. (C) 2010 Elsevier Ireland Ltd. All rights reserved. Radiotherapy and Oncology 96 (2010) 73-77
引用
收藏
页码:73 / 77
页数:5
相关论文
共 50 条
  • [21] ADVANTAGES AND LIMITATIONS OF COMPUTED-TOMOGRAPHY SCANS FOR TREATMENT PLANNING OF LUNG-CANCER
    MIRA, JG
    POTTER, JL
    FULLERTON, GD
    EZEKIEL, J
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1982, 8 (09): : 1617 - 1623
  • [22] Dynamic contrast-enhanced computed tomography
    Brix, G.
    Griebel, J.
    Delorme, S.
    RADIOLOGE, 2012, 52 (03): : 277 - 296
  • [23] The accuracy of contrast-enhanced computed tomography scans to detect postpartum haemorrhage: an observational study
    Mitsuyama, Yumi
    Katayama, Yusuke
    Oi, Kazuya
    Shimazaki, Junya
    Mimura, Kazuya
    Endo, Masayuki
    Shimazu, Takeshi
    BMC PREGNANCY AND CHILDBIRTH, 2022, 22 (01)
  • [24] The accuracy of contrast-enhanced computed tomography scans to detect postpartum haemorrhage: an observational study
    Yumi Mitsuyama
    Yusuke Katayama
    Kazuya Oi
    Junya Shimazaki
    Kazuya Mimura
    Masayuki Endo
    Takeshi Shimazu
    BMC Pregnancy and Childbirth, 22
  • [25] Assessing Tumor Response to Treatment in Patients with Lung Cancer Using Dynamic Contrast-Enhanced CT
    Strauch, Louise S.
    Eriksen, Rie O.
    Sandgaard, Michael
    Kristensen, Thomas S.
    Nielsen, Michael B.
    Lauridsen, Carsten A.
    DIAGNOSTICS, 2016, 6 (03)
  • [26] An unusual case of noncavitary hemorrhage revealed by intravenous contrast-enhanced computed tomography
    Nishiuchi, T
    Horikawa, H
    Hinami, J
    Yokota, J
    JOURNAL OF EMERGENCY MEDICINE, 2002, 22 (01): : 21 - 25
  • [27] Studying the complications of bariatric surgery with intravenous contrast-enhanced multidetector computed tomography
    Morandeira, C.
    Barcena, M. V.
    Bilbao, A.
    Perez, M.
    Ibanez, A. M.
    Isusi, M.
    Lecumberri, G.
    RADIOLOGIA, 2018, 60 (02): : 143 - 151
  • [28] Entering the Era of Non-fasting Intravenous Contrast-Enhanced Computed Tomography
    Chan, Y. S.
    Cho, C. C. M.
    Tong, C. S. L.
    Ng, A. W. H.
    HONG KONG JOURNAL OF RADIOLOGY, 2023, 26 (02): : 127 - 132
  • [29] Periodic contrast-enhanced computed tomography for thermal ablation monitoring: A feasibility study
    Brace, Christopher L.
    Mistretta, Charles A.
    Hinshaw, J. Louis
    Lee, Fred T., Jr.
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 4299 - +
  • [30] Suspected appendicitis in children: Rectal and intravenous contrast-enhanced versus intravenous contrast-enhanced CT
    Kharbanda, Anupam B.
    Taylor, George A.
    Bachur, Richard G.
    RADIOLOGY, 2007, 243 (02) : 520 - 526