Improved Estimation of Coronary Plaque and Luminal Attenuation Using a Vendor-specific Model-based Iterative Reconstruction Algorithm in Contrast-enhanced CT Coronary Angiography

被引:19
|
作者
Funama, Yoshinori [1 ]
Utsunomiya, Daisuke [2 ]
Hirata, Kenichiro [2 ]
Taguchi, Katsuyuki [3 ]
Nakaura, Takeshi [2 ]
Oda, Seitaro [2 ]
Kidoh, Masafumi [2 ]
Yuki, Hideaki [2 ]
Yamashita, Yasuyuki [2 ]
机构
[1] Kumamoto Univ, Dept Med Phys, Fac Life Sci, 4-24-1 Kuhonji, Kumamoto 8620976, Japan
[2] Kumamoto Univ, Dept Diagnost Radiol, Fac Life Sci, Kumamoto, Japan
[3] Johns Hopkins Univ, Sch Med, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD USA
基金
美国国家卫生研究院;
关键词
Coronary plaque attenuation; lumen-plaque contrast; full statistical iterative reconstruction algorithm; coronary CT angiography; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; RADIATION-DOSE REDUCTION; 320-DETECTOR ROW CT; ACUTE CHEST-PAIN; IMAGE QUALITY; INTRACORONARY ATTENUATION; SCANNER; EXPERIENCE; SOCIETY; IMPACT;
D O I
10.1016/j.acra.2017.02.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: To investigate the stabilities of plaque attenuation and coronary lumen for different plaque types, stenotic degrees, lumen densities, and reconstruction methods using coronary vessel phantoms and the visualization of coronary plaques in clinical patients through coronary computed tomography (CT) angiography. Materials and Methods: We performed 320-detector volume scanning of vessel tubes with stenosis and a tube without stenosis using three types of plaque CT numbers. The stenotic degrees were 50% and 75%. Images were reconstructed with filtered back projection (FBP) and two types of iterative reconstructions (AIDR3D and FIRST [forward-projected model-based iterative reconstruction solution]); with stenotic CT number of approximately 40, 80, and 150 HU (Hounsfield unit), respectively. In each case, the tubing of the coronary vessel was filled with diluted contrast material and distilled water to reach the target lumen CT numbers of approximately 350 HU and 450 HU, and 0 HU, respectively. Peak lumen and plaque CT numbers were measured to calculate the lumen-plaque contrast. In addition, we retrospectively evaluated the image quality with regard to coronary arterial lumen and the plaque in 10 clinical patients on a 4-point scale. Results: At 50% stenosis, the plaque CT number with contrast enhancement increased for FBP and AIDR3D, and the difference in the plaque CT number with and without contrast enhancement was 15-44 HU for FBP and 10-31 HU for AIDR3D. However, the plaque CT number for FIRST had a smaller variation and the difference with and without contrast enhancement was -12 to 8 HU. The visual evaluation score for the vessel lumen was 2.8 +/- 0.6, 3.5 +/- 0.5, and 3.7 +/- 0.5 for FBP, AIDR3D, and FIRST, respectively. Conclusions: The FIRST method controls the increase in plaque density and the lumen-plaque contrast. Consequently, it improves the visualization of coronary plaques in coronary CT angiography.
引用
收藏
页码:1070 / 1078
页数:9
相关论文
共 50 条
  • [41] Incremental Image Noise Reduction in Coronary CT Angiography Using a Deep Learning-Based Technique with Iterative Reconstruction
    Hong, Jung Hee
    Park, Eun-Ah
    Lee, Whal
    Ahn, Chulkyun
    Kim, Jong-Hyo
    KOREAN JOURNAL OF RADIOLOGY, 2020, 21 (10) : 1165 - 1177
  • [42] Impact of a vendor-specific motion-correction algorithm on image quality, interpretability, and diagnostic performance of daily routine coronary CT angiography: influence of heart rate on the effect of motion-correction
    Lee, Heon
    Kim, Jeong A.
    Lee, Ji Sung
    Suh, Jon
    Paik, Sang Hyun
    Park, Jai Soung
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 (08): : 1603 - 1612
  • [43] Impact of a vendor-specific motion-correction algorithm on image quality, interpretability, and diagnostic performance of daily routine coronary CT angiography: influence of heart rate on the effect of motion-correction
    Heon Lee
    Jeong A. Kim
    Ji Sung Lee
    Jon Suh
    Sang Hyun Paik
    Jai Soung Park
    The International Journal of Cardiovascular Imaging, 2014, 30 : 1603 - 1612
  • [44] Catheter contrast-enhanced coronary CT-angiography using an aortic root injection- preliminary technical development in four patients
    Kostaki G. Bis
    Anil N. Shetty
    Stacey Brewington
    William O’Neill
    The International Journal of Cardiovascular Imaging, 2004, 20 : 541 - 547
  • [45] Value of knowledge-based iterative model reconstruction in low-kV 256-slice coronary CT angiography
    Yuki, Hideaki
    Utsunomiya, Daisuke
    Funama, Yoshinori
    Tokuyasu, Shinichi
    Namimoto, Tomohiro
    Hirai, Toshinori
    Itatani, Ryo
    Katahira, Kazuhiro
    Oshima, Shuichi
    Yamashita, Yasuyuki
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2014, 8 (02) : 115 - 123
  • [46] Image quality of ct angiography using model-based iterative reconstruction in infants with congenital heart disease: Comparison with filtered back projection and hybrid iterative reconstruction
    Jia, Qianjun
    Zhuang, Jian
    Jiang, Jun
    Li, Jiahua
    Huang, Meiping
    Liang, Changhong
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 86 : 190 - 197
  • [47] The feasibility of sub-millisievert coronary CT angiography with low tube voltage, prospective ECG gating, and a knowledge-based iterative model reconstruction algorithm
    Chul Hwan Park
    Joohee Lee
    Chisuk Oh
    Kyung Hwa Han
    Tae Hoon Kim
    The International Journal of Cardiovascular Imaging, 2015, 31 : 197 - 203
  • [48] The feasibility of sub-millisievert coronary CT angiography with low tube voltage, prospective ECG gating, and a knowledge-based iterative model reconstruction algorithm
    Park, Chul Hwan
    Lee, Joohee
    Oh, Chisuk
    Han, Kyung Hwa
    Kim, Tae Hoon
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2015, 31 : 197 - 203
  • [49] Submillisievert CT using model-based iterative reconstruction with lung-specific setting: An initial phantom study
    Akinori Hata
    Masahiro Yanagawa
    Osamu Honda
    Tomoko Gyobu
    Ken Ueda
    Noriyuki Tomiyama
    European Radiology, 2016, 26 : 4457 - 4464
  • [50] Submillisievert CT using model-based iterative reconstruction with lung-specific setting: An initial phantom study
    Hata, Akinori
    Yanagawa, Masahiro
    Honda, Osamu
    Gyobu, Tomoko
    Ueda, Ken
    Tomiyama, Noriyuki
    EUROPEAN RADIOLOGY, 2016, 26 (12) : 4457 - 4464