Direct bidirectional angle-insensitive imaging of the flow signal intensity in Doppler optical coherence tomography

被引:8
|
作者
Piao, DQ [1 ]
Zhu, Q [1 ]
机构
[1] Univ Connecticut, Dept Elect & Comp Engn, Unit 1157, Storrs, CT 06269 USA
关键词
D O I
10.1364/AO.44.000348
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We introduce a new method, to our knowledge, for direct detection of flow signal intensity by stationary target rejection. In our system, two delay lines are constructed with identical scanning speed and ranging depth. One delay line is used for depth ranging as well as phase modulation, and the other one acts as a full-range retroreflector (FRRR). The signal from this FRRR carries the overall features of local phase modulation, and it is used as the local oscillator for coherent demodulation. With this setup, stationary targets can be rejected at a 4-kHz high-pass cutoff frequency of the filter that follows the demodulator, compared with 20 kHz for conventional fixed-frequency demodulation. This technique features angle insensitivity and provides flow direction as well by implementing standard in-phase and quadrature detection. Besides the direct directional detection of flow signal intensity, flow speed information can be acquired with postprocessing. (C) 2005 Optical Society of America.
引用
收藏
页码:348 / 357
页数:10
相关论文
共 50 条
  • [1] Angle independent flow assessment with bidirectional Doppler optical coherence tomography
    Blatter, Cedric
    Grajciar, Branislav
    Schmetterer, Leopold
    Leitgeb, Rainer A.
    [J]. OPTICS LETTERS, 2013, 38 (21) : 4433 - 4436
  • [2] Angle-insensitive flow measurement using Doppler bandwidth
    Yeung, KWW
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (03) : 574 - 580
  • [4] Simultaneous measurement of flow velocity and Doppler angle by the use of Doppler optical coherence tomography
    Wu, L
    [J]. OPTICS AND LASERS IN ENGINEERING, 2004, 42 (03) : 303 - 313
  • [5] Absolute flow measurement in chicken embryo based on optical coherence tomography with direct Doppler angle measuring
    Ma, Yushu
    Zhao, Yuqian
    Jiang, Huiwen
    Lin, Yang
    Li, Ang
    Meng, Ziyue
    Liu, Jian
    Yu, Yao
    Wang, Yi
    He, Zhonghai
    Shi, Wenbo
    Ma, Zhenhe
    [J]. INFRARED PHYSICS & TECHNOLOGY, 2022, 121
  • [6] Angle-insensitive amorphous silicon optical filter for fluorescence contact imaging
    Papageorgiou, Efthymios P.
    Zhang, Hui
    Boser, Bernhard E.
    Park, Catherine
    Anwar, Mekhail
    [J]. OPTICS LETTERS, 2018, 43 (03) : 354 - 357
  • [7] Angle-resolved Doppler flow imaging by detector-array-based optical coherence tomography
    Yokoyama, H
    Akiba, M
    Chan, KP
    Tanno, N
    [J]. CLEO(R)/PACIFIC RIM 2001, VOL I, TECHNICAL DIGEST, 2001, : 354 - 355
  • [8] Functional Doppler optical coherence tomography for cortical blood flow imaging
    Yu, Lingfeng
    Liu, Gangjun
    Nguyen, Elaine
    Choi, Bernard
    Chen, Zhongping
    [J]. PHOTONIC THERAPEUTICS AND DIAGNOSTICS VI, 2010, 7548
  • [9] Optical coherence Doppler tomography for quantitative cerebral blood flow imaging
    You, Jiang
    Du, Congwu
    Volkow, Nora D.
    Pan, Yingtian
    [J]. BIOMEDICAL OPTICS EXPRESS, 2014, 5 (09): : 3217 - 3230
  • [10] OPTICAL COHERENCE TOMOGRAPHY IMAGING OF THE IRIDOCORNEAL ANGLE
    Ohan, M. A.
    Chen, A.
    [J]. JOURNAL OF INVESTIGATIVE MEDICINE, 2023, 71 (01) : NP256 - NP256