Angle independent flow assessment with bidirectional Doppler optical coherence tomography

被引:19
|
作者
Blatter, Cedric [1 ]
Grajciar, Branislav [1 ]
Schmetterer, Leopold [1 ,2 ]
Leitgeb, Rainer A. [1 ]
机构
[1] Med Univ Vienna, Ctr Med Phys & Biomed Engn, A-1090 Vienna, Austria
[2] Med Univ Vienna, Dept Clin Pharmacol, A-1090 Vienna, Austria
关键词
RETINAL BLOOD-FLOW; SPEED; VESSELS; OCT;
D O I
10.1364/OL.38.004433
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Bidirectional Doppler optical coherence tomography is a stable and accurate method to extract the absolute velocity of vessels close to perpendicular to the optical axis by illuminating the sample under two different angles. However it requires knowledge of the vessel angle in the en face plane. In this Letter, we demonstrate that a direct calculation of the flow out of bidirectional Doppler cross sections perpendicular to the illumination plane is independent of that angle and of the Doppler angle, thereby improving the accuracy and flexibility of that technique. We validate our approach with an in vitro experiment and in vivo measurements of a human retinal vessel and discuss the practical limitations of this approach. The method yields accurate flow values for most vascular plexuses without precise knowledge of the vessel orientation. The precision gradually decreases for larger en face angles. (C) 2013 Optical Society of America
引用
收藏
页码:4433 / 4436
页数:4
相关论文
共 50 条
  • [1] Determination of fluid flow-velocity independent of Doppler angle by optical coherence tomography
    Proskurin, SG
    He, Y
    Wang, RK
    [J]. COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE VIII, 2004, 5316 : 136 - 140
  • [2] Direct bidirectional angle-insensitive imaging of the flow signal intensity in Doppler optical coherence tomography
    Piao, DQ
    Zhu, Q
    [J]. APPLIED OPTICS, 2005, 44 (03) : 348 - 357
  • [3] Simultaneous measurement of flow velocity and Doppler angle by the use of Doppler optical coherence tomography
    Wu, L
    [J]. OPTICS AND LASERS IN ENGINEERING, 2004, 42 (03) : 303 - 313
  • [4] Quantification of total retinal blood flow via dual -beam bidirectional Doppler optical coherence tomography for the assessment of neurovascular coupling
    Aschinger, G.
    Werkmeister, R.
    Garhofer, G.
    Schmetterer, L.
    [J]. ACTA OPHTHALMOLOGICA, 2015, 93
  • [5] Dual angle Scan Protocol with Doppler Optical Coherence Tomography for Retinal Blood Flow Measurement
    Tan, Ou
    Wang, Yimin
    Huang, David
    [J]. MEDICAL IMAGING 2011: COMPUTER-AIDED DIAGNOSIS, 2011, 7963
  • [6] In vivo bidirectional Doppler Fourier-domain optical coherence tomography for measurement of absolute flow velocities
    Werkmeister, Rene M.
    Dragostinoff, Nikolaus
    Pircher, Michael
    Goetzinger, Erich
    Hitzenberger, Christoph K.
    Leitgeb, Rainer A.
    Schmetterer, Leopold
    [J]. OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XIII, 2009, 7168
  • [8] Volumetric Doppler angle correction for ultrahigh-resolution optical coherence Doppler tomography
    You, Jiang
    Li, Ang
    Du, Congwu
    Pan, Yingtian
    [J]. APPLIED PHYSICS LETTERS, 2017, 110 (01)
  • [9] Doppler Optical Coherence Tomography
    Leitgeb, Rainer A.
    Werkmeister, Rene M.
    Blatter, Cedric
    Schmetterer, Leopold
    [J]. PROGRESS IN RETINAL AND EYE RESEARCH, 2014, 41 : 26 - 43
  • [10] Absolute flow measurement in chicken embryo based on optical coherence tomography with direct Doppler angle measuring
    Ma, Yushu
    Zhao, Yuqian
    Jiang, Huiwen
    Lin, Yang
    Li, Ang
    Meng, Ziyue
    Liu, Jian
    Yu, Yao
    Wang, Yi
    He, Zhonghai
    Shi, Wenbo
    Ma, Zhenhe
    [J]. INFRARED PHYSICS & TECHNOLOGY, 2022, 121