Using Robust Optimization for Skin Flashing in Intensity Modulated Radiation Therapy for Breast Cancer Treatment: A Feasibility Study

被引:11
|
作者
Liang, Xiaoying [1 ]
Bradley, Julie A. [1 ]
Vega, Raymond B. Mailhot [1 ]
Rutenberg, Michael [1 ]
Zheng, Dandan [2 ]
Getman, Nataliya [1 ]
Norton, Kelly W. [1 ]
Mendenhall, Nancy [1 ]
Li, Zuofeng [1 ]
机构
[1] Univ Florida, Coll Med, Dept Radiat Oncol, Jacksonville, FL 32209 USA
[2] Univ Nebraska Med Ctr, Dept Radiat Oncol, Omaha, NE USA
关键词
SETUP ERRORS; WHOLE-BREAST; RADIOTHERAPY; IMRT; UNCERTAINTIES; MOTION; IMPACT; RANGE; PLANS;
D O I
10.1016/j.prro.2019.09.017
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To study the feasibility and the effectiveness of a novel implementation of robust optimization on 2 sets of computed tomography (CT) data simultaneously for skin flashing in intensity modulated radiation therapy for breast cancer. Method and Materials: Five patients who received treatment to the breast and regional lymphatics were selected for this study. For each patient, 3 plans were generated using 3 different skin-flashing methods, including (1) a manual flash plan with optimization on the nominal planning target volume (PTV) not extending beyond the skin that required manually postplanning the opening of the multi-leaf collimator and jaw to obtain flash; (2) an expanded PTV plan with optimization on an expanded PTV that included the target in the air beyond the skin; and (3) a robust-optimized (RO) plan using robust optimization that simultaneously optimizes on the nominal CT data set and a simulated geometry error CT data set. The feasibility and the effectiveness of the robust optimization approach was investigated by comparing it with the 2 other methods. The robustness of the plan against target position variations was studied by simulating 0-, 5-, 10-, and 15-mm geometry errors. Results: The RO plans were the only ones able to meet acceptable criteria for all patients in both the nominal and simulated geometry error scenarios. The expanded PTV plans developed major deviation on the maximum dose to the PTV for 1 patient. For the manual flash plans, every patient developed major deviation either on 95% of the dose to the PTV or the maximum dose to the PTV in the simulated geometry error scenarios. The RO plan demonstrated the best robustness against the target position variation among the 3 methods of skin flashing. The doses to the lung and heart were comparable for all 3 planning techniques. Conclusion: Using robust optimization for skin flash in breast intensity modulated radiation therapy planning is feasible. Further investigation is warranted to confirm the clinical effectiveness of this novel approach. (C) 2019 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:59 / 69
页数:11
相关论文
共 50 条
  • [21] Intensity-Modulated Radiation Therapy for Breast Cancer Reply
    Jagsi, Reshma
    Griffith, Kent
    Moran, Jean M.
    Vicini, Frank
    Pierce, Lori
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2022, 112 (04): : 1064 - 1064
  • [22] Sea Change: A Decade of Intensity-Modulated Radiation Therapy for Treatment of Breast Cancer
    Smith, Grace L.
    Smith, Benjamin D.
    JNCI-JOURNAL OF THE NATIONAL CANCER INSTITUTE, 2020, 112 (03): : 221 - 223
  • [23] Intensity modulated radiation therapy (IMRT) decreases acute skin toxicity for women receiving radiation for breast cancer
    Freedman, GM
    Anderson, PR
    Li, JS
    Eisenberg, DF
    Hanlon, AL
    Wang, L
    Nicolaou, N
    AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2006, 29 (01): : 66 - 70
  • [24] Dosimetric effects of supine immobilization devices on the skin in intensity-modulated radiation therapy for breast cancer: a retrospective study
    Lv, Ran
    Yang, Guangyi
    Huang, Yongzhi
    Wang, Yanhong
    BMC CANCER, 2021, 21 (01)
  • [25] Dosimetric effects of supine immobilization devices on the skin in intensity-modulated radiation therapy for breast cancer: a retrospective study
    Ran Lv
    Guangyi Yang
    Yongzhi Huang
    Yanhong Wang
    BMC Cancer, 21
  • [26] Robust optimization of intensity modulated proton therapy
    Liu, Wei
    Zhang, Xiaodong
    Li, Yupeng
    Mohan, Radhe
    MEDICAL PHYSICS, 2012, 39 (02) : 1079 - 1091
  • [27] Intensity modulated radiation therapy and chemotherapy for Ioca advanced pancreatic cancer:Results of feasibility study
    Yong-Rui Bai Guo-Hua Wu Xu-Dong Wu Yuan Yao Yin Chen Ren-Hua Zhou Dong-Qin Lu
    World Journal of Gastroenterology, 2003, 9 (11) : 2561 - 2564
  • [28] Intensity modulated radiation therapy and chemotherapy for locally advanced pancreatic cancer: Results of feasibility study
    Bai, YR
    Wu, GH
    Guo, WJ
    Wu, XD
    Yao, Y
    Chen, Y
    Zhou, RH
    Lu, DQ
    WORLD JOURNAL OF GASTROENTEROLOGY, 2003, 9 (11) : 2561 - 2564
  • [29] Prospective Study of Intensity-Modulated Radiation Therapy for Locally Advanced Breast Cancer
    Bataille, Benoit
    Raoudha, Bennadji
    Le Tinier, Florence
    Basson, Laurent
    Escande, Alexandre
    Langin, Helene
    Tresch, Emmanuelle
    Crop, Frederik
    Darloy, Franck
    Carlier, Damien
    Lartigau, Eric
    Pasquier, David
    CANCERS, 2020, 12 (12) : 1 - 13
  • [30] The Study of AAA Algorithm and PBC Algorithm of Intensity Modulated Radiation Therapy for Breast Cancer
    Ma, C.
    Yin, Y.
    Lu, J.
    MEDICAL PHYSICS, 2010, 37 (06)