Position-sensitive soft X-ray detectors and their application

被引:0
|
作者
Goganov, D. A. [1 ]
Kazansky, B. V. [1 ]
Klimenskaya, D. A. [1 ]
Klochkova, I. B. [1 ]
Lebedev, A. G. [1 ]
Lepik, I. P. [1 ]
Pronichev, V. A. [2 ]
Protasov, Y. V. [1 ]
Serebryakov, A. S. [3 ]
机构
[1] OOO Elion, St Petersburg 191119, Russia
[2] Bourevestnik Res & Prod Enterprise, St Petersburg 195112, Russia
[3] ZAO Komita, St Petersburg 197101, Russia
关键词
PROPORTIONAL CHAMBERS; SPATIAL-RESOLUTION; DIFFRACTION; MUSCLE;
D O I
10.1134/S0020441215010182
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The designs and characteristics of linear and curved position-sensitive gas-filled detectors of soft X rays are described. The best result obtained with a gas mixture based on xenon is near 40 mu m (CuK (alpha)). The information of their use in X-ray scientific equipment is presented.
引用
收藏
页码:107 / 113
页数:7
相关论文
共 50 条
  • [31] Array of avalanche photodiodes as a position-sensitive X-ray detector
    Kishimoto, S
    Yoda, Y
    Seto, M
    Kitao, S
    Kobayashi, Y
    Haruki, R
    Harami, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 513 (1-2): : 193 - 196
  • [32] AN X-RAY GAS POSITION-SENSITIVE DETECTOR - CONSTRUCTION AND CHARACTERIZATION
    BARBOSA, AF
    GABRIEL, A
    CRAIEVICH, A
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07): : 2315 - 2317
  • [33] A microstrip germanium detector for position-sensitive X-ray spectroscopy
    Protic, D
    Stöhlker, T
    Beyer, HF
    Bojowald, J
    Borchert, G
    Gumberidze, A
    Hamacher, A
    Kozhuharov, C
    Ma, X
    Mohos, I
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (04) : 1048 - 1052
  • [34] A POSITION-SENSITIVE PHOTON DETECTOR FOR THE UV OR X-RAY RANGE
    ZUTAVERN, FJ
    SCHNATTERLY, SE
    KALLNE, E
    FRANCK, CP
    ATON, T
    RIFE, J
    NUCLEAR INSTRUMENTS & METHODS, 1980, 172 (1-2): : 351 - 355
  • [35] X-RAY FLUORESCENT SPECTROMETER WITH LINEAR POSITION-SENSITIVE DETECTOR
    DOLGIH, VE
    CHERKASHENKO, VM
    KURMAEV, EZ
    GOGANOV, DA
    OVCHINNIKOV, EK
    YARMOSHENKO, YM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 224 (1-2): : 117 - 119
  • [36] NOVEL X-RAY DIFFRACTOMETER POSITION-SENSITIVE DETECTOR SYSTEM
    FRAASS, BA
    GRANFORS, PR
    HILLEKE, RO
    SIMMONS, RO
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1984, 55 (09): : 1455 - 1460
  • [37] POSITION-SENSITIVE X-RAY DETECTOR FOR HEAO-A SATELLITE
    HELD, D
    WEISSKOP.MC
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1973, NS20 (01) : 140 - 144
  • [38] POSITION-SENSITIVE X-RAY DETECTOR FOR EQUATORIAL AND MERIDIONAL REFLECTIONS
    SAND, P
    CRIST, C
    BIOPHYSICAL JOURNAL, 1978, 21 (03) : A128 - A128
  • [39] A POSITION-SENSITIVE X-RAY-DETECTOR FOR AN X-RAY ION COINCIDENCE EXPERIMENT
    HUBRICHT, G
    TRABERT, E
    PHYSICA SCRIPTA, 1989, 39 (05): : 581 - 585
  • [40] X-ray spectroscopy of highly charged ions:: Application of position sensitive germanium detectors
    Stöhker, T
    Banas, D
    Beyer, HJ
    Gumberidze, A
    Tachenov, S
    Sierpowski, D
    Krings, T
    Kozhuharov, C
    Spillmann, U
    Ma, X
    Protic, D
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 366 - 368