PET and SPECT in Osteomyelitis and Prosthetic Bone and Joint Infections: A Systematic Review

被引:142
|
作者
van der Bruggen, Wouter [1 ]
Bleeker-Rovers, Chantal P. [2 ,3 ]
Boerman, Otto C. [1 ,3 ]
Gotthardt, Martin [1 ]
Oyen, Wim J. G. [1 ,3 ]
机构
[1] Radboud Univ Nijmegen, Med Ctr, Dept Nucl Med, NL-6500 HB Nijmegen, Netherlands
[2] Radboud Univ Nijmegen, Med Ctr, Dept Internal Med, NL-6500 HB Nijmegen, Netherlands
[3] Radboud Univ Nijmegen, Med Ctr, Nijmegen Inst Infect Inflammat & Immun N4i, NL-6500 HB Nijmegen, Netherlands
关键词
POSITRON-EMISSION-TOMOGRAPHY; TOTAL-HIP-ARTHROPLASTY; HUMAN-IMMUNOGLOBULIN-G; WHITE BLOOD-CELL; F-18; FDG-PET; LEUKOCYTE SCINTIGRAPHY; MUSCULOSKELETAL INFECTION; PERIPROSTHETIC INFECTION; GRANULATION TISSUES; INITIAL-EXPERIENCE;
D O I
10.1053/j.semnuclmed.2009.08.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective To review the literature on diagnostic accuracy and clinical value of single-photon emission computed tomography (SPECT) and positron emission tomography (PET) for imaging of bone and joint infections. Methods The PubMed/MEDLINE and Embase (OvidSP) literature databases were systematically searched for publications on SPECT and PET on osteomyelitis and prosthetic bone and joint infections using specific guidelines with MeSH-terms, truncations, and completion using cross-references. Results In 44 original articles (15 for SPECT and 29 for (18)F-fluorodeoxyglucose [FDG]-PET) on osteomyelitis and prosthetic bone and joint infection, 1634 patients were included (580 patients SPECT, 1054 patients FOG-PET). Level of evidence (Oxford criteria) was 2-3b. For SPEC, the highest diagnostic accuracy of 95% for diagnosis of bone and joint infections is achieved with combined (111)In-WBC and (99m)Tc-sulfur colloid. Acceptable diagnostic accuracy was also obtained with (99m)Tc-WBC or (111)In-WBC combined with (99m)Tc-methylene diphosphonate ((99m)Tc-MDP). FDG-PET is useful for diagnosis of osteomyelitis with a sensitivity and specificity generally over 95%. In patients with orthopedic implant infections, sensitivity varies widely from 28% to 91% and specificity from 9% to 97%. This variation in FDG-PET performance in orthopedic implant infections depends largely on the (use of different) criteria to diagnose infection. Determination of the best criteria is still a matter of debate. Conclusions SPECT/computed tomography (CT) with (111)In-WBC combined with (99m)Tc-MDP or (99m)Tc-sulfur colloid seems to be the best imaging technique for diagnosis of bone and joint infections. FDG-PET is also useful for diagnosis of osteomyelitis with improved spatial resolution over SPECT imaging, allowing more accurate localization. Localization can be further improved by adding CT. Diagnosis of orthopedic implant infections with FOG-PET depends strongly on the localization of the implant and the criteria used to diagnose infection. Confirmation of well defined criteria to diagnose infection on FDG-PET in patients with metallic implants is thus of paramount importance for optimal diagnosis. Semin Nucl Med 40:3-15 (C) 2010 Elsevier Inc. All rights reserved.
引用
收藏
页码:3 / 15
页数:13
相关论文
共 50 条
  • [41] Single nucleotide polymorphisms in the development of osteomyelitis and prosthetic joint infection: a narrative review
    Zhou, Jia-Qi
    Liu, Zi-Xian
    Zhong, Hong-Fa
    Liu, Guan-Qiao
    Ding, Ming-Cong
    Zhang, Yu
    Yu, Bin
    Jiang, Nan
    FRONTIERS IN IMMUNOLOGY, 2024, 15
  • [42] Efficacy and Tolerability of Linezolid in Chronic Osteomyelitis and Prosthetic Joint Infections: A Case-Control Study
    Papadopoulos, A.
    Plachouras, D.
    Giannitsioti, E.
    Poulakou, G.
    Giamarellou, H.
    Kanellakopoulou, K.
    JOURNAL OF CHEMOTHERAPY, 2009, 21 (02) : 165 - 169
  • [43] 'To bead or not to bead?' Treatment of osteomyelitis and prosthetic joint-associated infections with gentamicin bead chains
    Barth, Roos E.
    Vogely, H. Charles
    Hoepelman, Andy I. M.
    Peters, Edgar J. G.
    INTERNATIONAL JOURNAL OF ANTIMICROBIAL AGENTS, 2011, 38 (05) : 371 - 375
  • [44] CHRONIC OSTEOMYELITIS - RISK OF PROSTHETIC JOINT INFECTION
    LANGE, RH
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1987, 258 (15): : 2125 - 2125
  • [45] Prosthetic-joint infections
    Glatt, AE
    NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (01): : 95 - 96
  • [46] Enterococcal Prosthetic Joint Infections
    Weightman, N. C.
    Long, S. T.
    Conroy, J.
    Kerr, K. G.
    INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2008, 12 : E212 - E213
  • [47] INFECTIONS SIMULATING BONE-TUMORS - A REVIEW OF SUBACUTE OSTEOMYELITIS
    LINDENBAUM, S
    ALEXANDER, H
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1984, (184) : 193 - 203
  • [48] PROSTHETIC JOINT INFECTIONS IN THE ELDERLY
    POWERS, KA
    TERPENNING, MS
    VOICE, RA
    KAUFFMAN, CA
    AMERICAN JOURNAL OF MEDICINE, 1990, 88 (5N): : N9 - N13
  • [49] Prosthetic joint infections in the elderly
    G. De Angelis
    N. T. Mutters
    L. Minkley
    F. Holderried
    E. Tacconelli
    Infection, 2015, 43 : 629 - 637
  • [50] Prosthetic Joint Infections: an Update
    C. L. Abad
    A. Haleem
    Current Infectious Disease Reports, 2018, 20