Optimal switching placement for customer interruption cost minimization

被引:0
|
作者
Lin, C. H. [1 ]
Chen, C. S. [2 ]
Chuang, H. J. [3 ]
Li, C. S. [1 ]
Huang, M. Y. [2 ]
Huang, C. W. [4 ]
机构
[1] Natl Kaohsiung Univ Appl Sci, Dept Elect Engn, Kaohsiung 807, Taiwan
[2] Natl Sun Yat Sen Univ, Dept Elect Engn, Kaohsiung 80424, Taiwan
[3] Kao Yuan Univ, Dept Elect Engn, Kaohsiung, Taiwan
[4] Taiwan Power Co, Power Res Inst, Kaohsiung, Taiwan
关键词
distribution automation system; immune algorithm; outage management system;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
To enhance the cost effectiveness of distribution automation system (DAS), this paper proposes the immune algorithm (IA) to derive the optimal placement of switching devices by minimizing the total cost of customer service outage and investment cost of line switches. The reliability index of each service zone defined by the boundary switches is derived to solve the expected energy not served due to fault contingency and the customer interruption cost is then determined according to the. customer type and power consumption within the service zone. To demonstrate the effectiveness of proposed IA methodology to solve the optimal placement of line switches, a practical distribution system of Taiwan Power Company (Taipower) is selected for computer simulation to explore the cost benefit of line switch placement for DAS.
引用
收藏
页码:312 / +
页数:2
相关论文
共 50 条
  • [1] Feeder-switch relocation for customer interruption cost minimization
    Teng, JH
    Lu, CN
    IEEE TRANSACTIONS ON POWER DELIVERY, 2002, 17 (01) : 254 - 259
  • [2] Switches optimal placement of automated distribution networks with probability customer interruption cost model: A case study
    Karimi, Hassan
    Niknam, Taher
    Aghaei, Jamshid
    GhasemiGarpachi, Mina
    Dehghani, Moslem
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2021, 127
  • [3] Customer Interruption Cost Minimization Based on Graph Theory in Smart Distribution Grid
    Hendi, Reza Baradaran
    Seyed-Shenava, Seyed-Jalal
    2013 SMART GRID CONFERENCE (SGC'13), 2013, : 47 - 52
  • [4] A Comparative Study of Optimal PMU Placement Algorithms for Cost Minimization
    Deese, Anthony S.
    Nugent, Tim
    Coppi, Stephen
    2014 IEEE PES GENERAL MEETING - CONFERENCE & EXPOSITION, 2014,
  • [5] Customer Interruption Cost in Smart Grids
    Safdarian, Amir
    Lehtonen, Matti
    Fotuhi-Firuzabad, Mahmud
    Billinton, Roy
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2014, 29 (02) : 994 - 995
  • [6] Optimal Distribution Automation Devices Placement for Reliability Improvement of a Real Distribution Network with Sub-Feeders Considering Customer Interruption Cost
    Masimula, Jabulani
    Awodele, Kehinde
    2019 SOUTHERN AFRICAN UNIVERSITIES POWER ENGINEERING CONFERENCE/ROBOTICS AND MECHATRONICS/PATTERN RECOGNITION ASSOCIATION OF SOUTH AFRICA (SAUPEC/ROBMECH/PRASA), 2019, : 732 - 737
  • [7] Customer interruption cost assessment of domestic residential customer using customer survey
    Lee, Byung-Sung
    Chu, Cheol-Min
    Transactions of the Korean Institute of Electrical Engineers, 2010, 59 (10): : 1792 - 1796
  • [8] Impact of distributed generation resources on customer interruption cost
    Rajabi-Ghahnavie, A
    Fotuhi-Firuzabad, M
    Parniani, M
    2004 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY - POWERCON, VOLS 1 AND 2, 2004, : 856 - 861
  • [9] Customer interruption cost assessment: an Indian commercial survey
    Kaur, N
    Singh, G
    Bedi, MS
    POWERCON 2002: INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY, VOLS 1-4, PROCEEDINGS, 2002, : 880 - 884
  • [10] Impact of energy end use and customer interruption cost on optimal allocation of switchgear in constrained distribution networks
    Helseth, Arild
    Holen, Arne T.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (03) : 1419 - 1425