Adversarial Resolution Enhancement for Electrical Capacitance Tomography Image Reconstruction

被引:11
|
作者
Deabes, Wael [1 ,2 ]
Abdel-Hakim, Alaa E. [1 ,3 ]
Bouazza, Kheir Eddine [1 ,4 ]
Althobaiti, Hassan [1 ]
机构
[1] Umm Al Qura Univ, Dept Comp Sci Jamoum, Mecca 25371, Saudi Arabia
[2] Mansoura Univ, Comp & Syst Engn Dept, Mansoura 35516, Egypt
[3] Assiut Univ, Elect Engn Dept, Assiut 71516, Egypt
[4] Univ Oran, Lab Informat & Technol Informat Oran LITIO, Oran 31000, Algeria
关键词
ECT; image reconstruction; deep learning; CGAN; ARE-ECT; SYSTEM; ALGORITHM;
D O I
10.3390/s22093142
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
High-quality image reconstruction is essential for many electrical capacitance tomography (CT) applications. Raw capacitance measurements are used in the literature to generate low-resolution images. However, such low-resolution images are not sufficient for proper functionality of most systems. In this paper, we propose a novel adversarial resolution enhancement (ARE-ECT) model to reconstruct high-resolution images of inner distributions based on low-quality initial images, which are generated from the capacitance measurements. The proposed model uses a UNet as the generator of a conditional generative adversarial network (CGAN). The generator's input is set to the low-resolution image rather than the typical random input signal. Additionally, the CGAN is conditioned by the input low-resolution image itself. For evaluation purposes, a massive ECT dataset of 320 K synthetic image-measurement pairs was created. This dataset is used for training, validating, and testing the proposed model. New flow patterns, which are not exposed to the model during the training phase, are used to evaluate the feasibility and generalization ability of the ARE-ECT model. The superiority of ARE-ECT, in the efficient generation of more accurate ECT images than traditional and other deep learning-based image reconstruction algorithms, is proved by the evaluation results. The ARE-ECT model achieved an average image correlation coefficient of more than 98.8% and an average relative image error about 0.1%.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Image Reconstruction for Electrical Capacitance Tomography Through Redundant Sensitivity Matrix
    de Moura, Hector Lise
    Pipa, Daniel Rodrigues
    Wrasse, Aluisio do Nascimento
    da Silva, Marco Jose
    IEEE SENSORS JOURNAL, 2017, 17 (24) : 8157 - 8165
  • [42] Image Reconstruction Algorithm Based on Compressed Sensing for Electrical Capacitance Tomography
    Zhang, Lifeng
    Liu, Zhaolin
    Tian, Pei
    EIGHTH INTERNATIONAL CONFERENCE ON DIGITAL IMAGE PROCESSING (ICDIP 2016), 2016, 10033
  • [43] Trust Region Algorithm for Image Reconstruction in Electrical Capacitance Tomography System
    Wang Lili
    Chen Yu
    Chen Deyun
    Yu Xiaoyang
    2011 INTERNATIONAL CONFERENCE ON COMPUTER SCIENCE AND NETWORK TECHNOLOGY (ICCSNT), VOLS 1-4, 2012, : 204 - 209
  • [44] A reconstruction method for electrical capacitance tomography based on image fusion techniques
    Olmos, A. Martinez
    Botella, G.
    Castillo, E.
    Morales, Diego P.
    Banqueri, J.
    Garcia, A.
    DIGITAL SIGNAL PROCESSING, 2012, 22 (06) : 885 - 893
  • [45] A multi-scale image reconstruction algorithm for electrical capacitance tomography
    Lei, Jing
    Liu, Shi
    Li, Zhihong
    Sun, Meng
    Wang, Xueyao
    APPLIED MATHEMATICAL MODELLING, 2011, 35 (06) : 2585 - 2606
  • [46] Optimization of sensor structural parameters and image reconstruction for electrical capacitance tomography
    Ming, Gao
    Deyun, Chen
    Lili, Wang
    Xiaoyang, Yu
    International Journal of Control and Automation, 2015, 8 (01): : 56 - 58
  • [47] Nonlinear image reconstruction for electrical capacitance tomography using experimental data
    Soleimani, Manuchehr
    Lionheart, William R. B.
    Meas. Sci. Technol., 10 (1987-1996):
  • [48] An image reconstruction algorithm based on the semiparametric model for electrical capacitance tomography
    Lei, J.
    Liu, S.
    Guo, H. H.
    Li, Z. H.
    Li, J. T.
    Han, Z. X.
    COMPUTERS & MATHEMATICS WITH APPLICATIONS, 2011, 61 (09) : 2843 - 2853
  • [49] Simulation Studies on Image Reconstruction Algorithm for Portable Electrical Capacitance Tomography
    Hamzah, A. A.
    Rahim, R. A.
    Mohamad, E. J.
    Pusppanathan, J.
    Kadir, K. A.
    Ameran, H. L. M.
    Mohamed, M. N. A.
    INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING, 2018, 10 (08): : 107 - 111
  • [50] Image reconstruction algorithm accelerated by polynomial for electrical capacitance tomography system
    Harbin University of Science and Technology, Harbin 150080, China
    Yi Qi Yi Biao Xue Bao, 2008, 12 (2538-2542):