Background: Cigarette smoking predisposes to vascular disease. Our study aimed to assess the acute effects of cigarette smoking on peripheral microcirculation using near-infrared spectroscopy (NIRS) and to compare microcirculatory function of smokers with that of nonsmokers. Methods: We examined 65 healthy volunteers: 25 smokers (14 men and 11 women; age range, 20 to 27 years) and 40 nonsmokers (31 men and 9 women; age range, 19 to 38 years). Smokers had refrained from smoking for 2 h prior to the examination. Tissue 02 saturation (Sto(2)), defined as the percentage of hemoglobin saturation in the microvasculature compartments, was measured with a probe placed on the thenar muscle. Sto(2) baseline values were recorded for 5 min. Subsequently, the brachial artery occlusion technique was applied to evaluate microcirculatory function before, during, and after smoking one cigarette. Results: Sto(2) before smoking was 85 +/- 6% (mean +/- SD), not differing significantly between men and women (84.4 +/- 6.6% vs 85.6 +/- 5.8%, respectively; p = 0.721). Sto(2) did not change significantly during smoking. O-2 consumption rate was significantly greater in women (33.4 +/- 6.7 Sto(2) U/min vs 25.7 +/- 7.1 Sto(2) U/min, p = 0.032) at baseline and throughout the smoking session. O-2 consumption rate was reduced during smoking (p < 0.001) and at 5 min after the smoking session. Smoking had a significant effect on vascular reactivity (p = 0.015), with no significant differences between genders. Five minutes after smoking, vascular reactivity had returned to approximately normal levels. Conclusion: Smoking acutely affects microcirculatory function. NIRS is a noninvasive, operator-independent technique that can document these effects. It seems promising for the prospective evaluation of the effects of long-term exposure to cigarette smoke.
引用
下载
收藏
页码:1479 / 1485
页数:7
相关论文
共 50 条
  • [21] Reproducibility of Skeletal Muscle Oxidative Function and Postexercise Kinetics Using Near-Infrared Spectroscopy
    Southern, William M.
    Reynolds, Mary Ann
    McCully, Kevin K.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (05): : 8 - 8
  • [22] Sourcebook update: using near-infrared spectroscopy to assess skeletal muscle oxygen uptake
    Pelka, Edward Z.
    Davis, B. Ryan
    McDaniel, John
    ADVANCES IN PHYSIOLOGY EDUCATION, 2024, 48 (03) : 566 - 572
  • [23] Peripheral circulation evaluation with near-infrared spectroscopy in skeletal muscle during cardiopulmonary bypass
    Mukaida, H.
    Matsushita, S.
    Inotani, T.
    Futaki, S.
    Takano, A.
    Watanabe, M.
    Morita, T.
    Miida, T.
    Amano, A.
    PERFUSION-UK, 2015, 30 (08): : 653 - 659
  • [24] EXTRACEREBRAL ABSORPTION OF NEAR-INFRARED LIGHT INFLUENCES THE DETECTION OF INCREASED CEREBRAL OXYGENATION MONITORED BY NEAR-INFRARED SPECTROSCOPY
    GERMON, TJ
    YOUNG, AER
    MANARA, AR
    NELSON, RJ
    JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1995, 58 (04): : 477 - 479
  • [25] Muscle Near-Infrared Spectroscopy Signals versus Venous Blood Hemoglobin Oxygen Saturation in Skeletal Muscle
    Sun, Yi
    Ferguson, Brian S.
    Rogatzki, Mmatthew J.
    Mcdonald, James R.
    Gladden, L. Bruce
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2016, 48 (10): : 2013 - 2020
  • [26] Comparison of forearm muscle oxygenation dynamics during isometric and isotonic contractions monitored by near-infrared spectroscopy
    Cheung, A.
    Tu, L.
    Sahragard, F.
    Shadgan, B.
    BIOPHOTONICS IN EXERCISE SCIENCE, SPORTS MEDICINE, HEALTH MONITORING TECHNOLOGIES, AND WEARABLES, 2020, 11237
  • [27] NEAR-INFRARED OXIMETRY AND NEAR-INFRARED SPECTROSCOPY
    OWENREECE, H
    ELWELL, CE
    FALLON, P
    GOLDSTONE, J
    SMITH, M
    ANAESTHESIA, 1994, 49 (12) : 1102 - 1103
  • [28] Changes in the microcirculation during human endotoxemia measured with near-infrared spectroscopy
    P Pickkers
    K Gotink
    A Draisma
    J van der Hoeven
    Critical Care, 10 (Suppl 1):
  • [29] Contrast Baths, Intramuscular Hemodynamics, and Oxygenation as Monitored by Near-Infrared Spectroscopy
    Shadgan, Babak
    Pakravan, Amir H.
    Hoens, Alison
    Reid, W. Darlene
    JOURNAL OF ATHLETIC TRAINING, 2018, 53 (08) : 782 - 787
  • [30] Effects of sepsis on venous microcirculation: non-invasive evaluation by quantitative near-infrared spectroscopy
    V Papi
    V Defraia
    M Sandri
    R Romano
    R De Blasi
    Critical Care, 15 (Suppl 1):