Vacuum vessel contact dose build-up from start to end of ITER operations

被引:0
|
作者
Cambi, G [1 ]
Cepraga, DG [1 ]
Frisoni, M [1 ]
Carloni, F [1 ]
Chiasera, A [1 ]
机构
[1] Univ Bologna, Dept Phys, I-40126 Bologna, Italy
关键词
D O I
10.1109/FUSION.2003.1426611
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The paper presents the ITER Vacuum Vessel (VV) contact dose build up evaluation from start to end of the machine life (expected to occur after about 20 years of operations, corresponding to an average neutron fluence of 0.5 MWa/m(2) on the First Wall). The reference design used for ITER Generic Site Safety Report (GSSR) has been considered. Results are given for the inboard and outboard W regions (and for both the front and rear 316L(N)-IG walls) in the radial equatorial plane. The Sn calculation sequence SCALENEA-1 (with the FISPACT-99 activation code) has been used for the analysis. The results point out that after only 20 seconds of irradiation at the nominal neutron power load, the contact dose of the most activated W zone (i.e. the outboard region, front wall), reaches the hands-on limit of 10 muSv/h just after few months cooling time, requiring remote handling operations on that component in maintenance cells.
引用
收藏
页码:156 / 159
页数:4
相关论文
共 50 条
  • [41] Absorbed dose measurements in the build-up region of flattened versus unflattened megavoltage photon beams
    De Puysseleyr, Annemieke
    Lechner, Wolfgang
    De Neve, Wilfried
    Georg, Dietmar
    De Wagter, Carlos
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2016, 26 (02): : 177 - 183
  • [42] The current column contraction and ion charge increase induced by the current build-up in a pulsed vacuum discharge
    E. A. Zverev
    I. A. Krinberg
    Technical Physics Letters, 2000, 26 : 288 - 291
  • [43] The current column contraction and ion charge increase induced by the current build-up in a pulsed vacuum discharge
    Zverev, EA
    Krinberg, IA
    TECHNICAL PHYSICS LETTERS, 2000, 26 (04) : 288 - 291
  • [44] Dose Evaluation of Build-up Region of Photon Beam using Thermoluminescence Dosimeter (TLD) Sheet
    Sasaki, K.
    Shiota, Y.
    Miura, M.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S917 - S917
  • [45] The effect of electron collimator leaf shape on the build-up dose in narrow electron MLC fields
    Vatanen, T.
    Traneus, E.
    Vaananen, A.
    Lahtinen, T.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (23): : 7211 - 7226
  • [46] Assessment the accuracy of dose calculation in build-up region for two radiotherapy treatment planning systems
    Farhood, Bagher
    Toossi, Mohammad Taghi Bahreyni
    Ghorbani, Mahdi
    Salari, Elahe
    Knaup, Courtney
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2017, 13 (06) : 968 - 973
  • [47] Effect of thermoplastic mask hole diameter on dose distribution in the build-up region of medical LINAC
    Demir, Hikmettin
    Gul, Osman Vefa
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2024, 17 (02)
  • [48] Measurement of build-up region dose with optical cone-beam computed tomography scanner
    Garisto, Sarah
    Jordan, Kevin
    10TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2019, 1305
  • [49] Mechanical properties of carbon steel depending on the rate of the dose build-up of nitrogen and argon ions
    V. L. Vorob’ev
    P. V. Bykov
    V. Ya. Bayankin
    A. A. Shushkov
    A. V. Vakhrushev
    The Physics of Metals and Metallography, 2014, 115 : 800 - 804
  • [50] Comparing dose in the build-up region between compensator- and MLC-based IMRT
    Javedan, Khosrow
    Zhang, Geoffrey G.
    Hoffe, Sarah
    Feygelman, Vladimir
    Forster, Kenneth
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2012, 13 (05): : 12 - 23