Simultaneous atmospheric CO, N2O and H2O detection using a single quantum cascade laser sensor based on dual-spectroscopy techniques

被引:86
|
作者
Li, Jingsong [1 ]
Deng, Hao [1 ]
Sun, Juan [1 ]
Yu, Benli [1 ]
Fischer, Horst [2 ]
机构
[1] Anhui Univ, Minist Educ, Key Lab Optoelect Informat Acquisit & Manipulat, Hefei, Peoples R China
[2] Max Planck Inst Chem, Hahn Meitner Weg 1, D-55128 Mainz, Germany
来源
基金
中国国家自然科学基金;
关键词
QCL; Carbon monoxide; Nitrous oxide; Water vapor; DAS; WMS; WAVELENGTH-MODULATION SPECTROSCOPY; BROADENING COEFFICIENTS; GAS DETECTION; REAL-TIME; METHANE; BREATH; CH4;
D O I
10.1016/j.snb.2016.03.089
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A single continuous wave (CW) room-temperature (RT) quantum cascade laser (QCL) sensor based on dual spectroscopic techniques was demonstrated and developed for simultaneous measurement of atmospheric carbon monoxide (CO), nitrous oxide (N2O) and water vapor (H2O). The newly developed detection scheme combines the benefits of absolute concentration measurements using calibration free direct absorption spectroscopy (DAS) with higher sensitive wavelength modulation spectroscopy (WMS), which offers the possibility of calibration-free trace gases concentration detection with a 3-4 fold improvement in measurement precision and a significant decrease in optimal signal averaging time. By using the DAS calibrated WMS-2f detection scheme, Allan deviation analysis indicates that measurement precision of 1.64 ppb for CO, 1.15 ppb for N2O and 50.4 ppm for H2O was achieved with a 1-s integration time, which can be further improved to 0.21 ppb, 0.18 ppb and 5.65 ppm by averaging up to 75 s. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:723 / 732
页数:10
相关论文
共 50 条
  • [21] Photoacoustic detection of NO2 and N2O using quantum cascade lasers
    Lima, J. P.
    Vargas, H.
    Miklos, A.
    Angelmahr, M.
    Hess, P.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2006, 85 (2-3): : 279 - 284
  • [22] Photoacoustic detection of NO2 and N2O using quantum cascade lasers
    J.P. Lima
    H. Vargas
    A. Miklós
    M. Angelmahr
    P. Hess
    Applied Physics B, 2006, 85 : 279 - 284
  • [23] A portable N2O sensor based on quartz-enhanced photoacoustic spectroscopy with a distributed-feedback quantum cascade laser for medical and atmospheric applications
    Bayrakli, Ismail
    OPTICAL AND QUANTUM ELECTRONICS, 2021, 53 (11)
  • [24] A portable N2O sensor based on quartz-enhanced photoacoustic spectroscopy with a distributed-feedback quantum cascade laser for medical and atmospheric applications
    Ismail Bayrakli
    Optical and Quantum Electronics, 2021, 53
  • [25] Ambient detection of CH4 and N2O by Quantum Cascade Laser
    Castillo, Paulo Cesar
    Sydoryk, Ihor
    Gross, Barry
    Moshary, Fred
    ADVANCED ENVIRONMENTAL, CHEMICAL, AND BIOLOGICAL SENSING TECHNOLOGIES X, 2013, 8718
  • [26] Pure amplitude and wavelength modulation spectroscopy for detection of N2O using a three-section quantum cascade laser
    Patimisco, Pietro
    Sampaolo, Angelo
    Bidaux, Yves
    Bismuto, Alfredo
    Scott, Marshall
    Jiang, James
    Tittel, Frank K.
    Spagnolo, Vincenzo
    QUANTUM SENSING AND NANO ELECTRONICS AND PHOTONICS XIV, 2017, 10111
  • [27] CW EC-QCL Based Sensor for Simultaneous HOD/H2O, N2O and CH4 Detection by Multi-pass Absorption Spectroscopy
    Yu, Yajun
    Sanchez, Nancy P.
    Griffin, Robert J.
    Tittel, Frank K.
    2016 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2016,
  • [28] Re-injection off-axis integrated cavity output spectroscopy for the simultaneous detection of N2O, H2O and CO with a mid-infrared QCL laser
    Yang, Xi
    Zhang, Zhirong
    Xia, Hua
    Sun, Pengshuai
    Pang, Tao
    Wu, Bian
    Liu, Xu
    Guo, Qiang
    ANALYST, 2024, 149 (03) : 909 - 916
  • [29] CONDENSATION COEFFICIENT MEASUREMENTS OF H2O, N2O, AND CO2
    BRYSON, CE
    CAZCARRA, V
    LEVENSON, LL
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY, 1974, 11 (01): : 411 - 416
  • [30] Inter-pulse spectroscopy based on room-temperature pulsed quantum-cascade laser for N2O detection
    Wang Min
    Chen Jie
    Liu Niu
    Wang Ya
    MEASURING TECHNOLOGY AND MECHATRONICS AUTOMATION IV, PTS 1 AND 2, 2012, 128-129 : 607 - 610