Heart Rate Detection Using Microsoft Kinect: Validation and Comparison to Wearable Devices

被引:40
|
作者
Gambi, Ennio [1 ]
Agostinelli, Angela [1 ]
Belli, Alberto [1 ]
Burattini, Laura [1 ]
Cippitelli, Enea [1 ]
Fioretti, Sandro [1 ]
Pierleoni, Paola [1 ]
Ricciuti, Manola [1 ]
Sbrollini, Agnese [1 ]
Spinsante, Susanna [1 ]
机构
[1] Univ Politecn Marche, Dipartimento Ingn Informaz, Via Brecce Bianche 12, I-60131 Ancona, Italy
关键词
heart rate; contactless sensing; EVM; Kinect; RGB-D sensors; photoplethysmography; videoplethysmography; RATE-VARIABILITY; COMPONENT ANALYSIS; EXTRACTION; NONCONTACT; SENSORS; SYSTEM;
D O I
10.3390/s17081776
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Contactless detection is one of the new frontiers of technological innovation in the field of healthcare, enabling unobtrusive measurements of biomedical parameters. Compared to conventional methods for Heart Rate (HR) detection that employ expensive and/or uncomfortable devices, such as the Electrocardiograph (ECG) or pulse oximeter, contactless HR detection offers fast and continuous monitoring of heart activities and provides support for clinical analysis without the need for the user to wear a device. This paper presents a validation study for a contactless HR estimation method exploiting RGB (Red, Green, Blue) data from a Microsoft Kinect v2 device. This method, based on Eulerian Video Magnification (EVM), Photoplethysmography (PPG) and Videoplethysmography (VPG), can achieve performance comparable to classical approaches exploiting wearable systems, under specific test conditions. The output given by a Holter, which represents the gold-standard device used in the test for ECG extraction, is considered as the ground-truth, while a comparison with a commercial smartwatch is also included. The validation process is conducted with two modalities that differ for the availability of a priori knowledge about the subjects' normal HR. The two test modalities provide different results. In particular, the HR estimation differs from the ground-truth by 2% when the knowledge about the subject's lifestyle and his/her HR is considered and by 3.4% if no information about the person is taken into account.
引用
收藏
页数:18
相关论文
共 50 条
  • [11] Fetal heart rate monitoring device using condenser microphone sensor: Validation and comparison to standard devices
    Ahmad, Husna Azyan Binti
    El-Badawy, Ismail M.
    Singh, Om Prakash
    Hisham, Rozana Binti
    Malarvili, M. B.
    TECHNOLOGY AND HEALTH CARE, 2018, 26 (04) : 573 - 579
  • [12] Real-time monitoring of heart rate by processing of Microsoft Kinect™ 2.0 generated streams
    Bosi, Ilaria
    Cogerino, Chiara
    Bazzani, Marco
    2016 INTERNATIONAL MULTIDISCIPLINARY CONFERENCE ON COMPUTER AND ENERGY SCIENCE (SPLITECH), 2016, : 1 - 6
  • [13] Validation of Static and Dynamic Balance Assessment Using Microsoft Kinect for Young and Elderly Populations
    Eltoukhy, Moataz A.
    Kuenze, Christopher
    Oh, Jeonghoon
    Signorile, Joseph F.
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2018, 22 (01) : 147 - 153
  • [14] Detection of respiratory rate using pulse wave on near infrared wearable devices
    Chen X.-C.
    Zhao H.
    Li H.
    Zheng H.-X.
    Chen, Xing-Chi (chenxingchi999@126.com), 1600, Chinese Academy of Sciences (24): : 1297 - 1306
  • [15] Detection of Cardiopulmonary Activity and Related Abnormal Events Using Microsoft Kinect Sensor
    Al-Naji, Ali
    Chahl, Javaan
    SENSORS, 2018, 18 (03)
  • [16] Efficient Source Separation Algorithms for Acoustic Fall Detection Using a Microsoft Kinect
    Li, Yun
    Ho, K. C.
    Popescu, Mihail
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2014, 61 (03) : 745 - 755
  • [17] Non-contact detection of human heart rate with Kinect
    Zhou, Liqian
    Yin, Ming
    Xu, Xi
    Yuan, Xinpan
    Liu, Xiaojun
    CLUSTER COMPUTING-THE JOURNAL OF NETWORKS SOFTWARE TOOLS AND APPLICATIONS, 2019, 22 (Suppl 4): : S8199 - S8206
  • [18] Non-contact detection of human heart rate with Kinect
    Liqian Zhou
    Ming Yin
    Xi Xu
    Xinpan Yuan
    Xiaojun Liu
    Cluster Computing, 2019, 22 : 8199 - 8206
  • [19] Heart Rate Monitoring Using Kinect and Color Amplification
    Smilkstein, Tina
    Buenrostro, Miguel
    Kenyon, Alan
    Lienemann, Matthew
    Larson, Grace
    2014 IEEE Healthcare Innovation Conference (HIC), 2014, : 60 - 62
  • [20] Examining weekly heart rate variability changes: a comparison between wearable devices running head: weekly heart rate variability changes
    Ruiz-Alias, Santiago A.
    Marcos-Blanco, Aitor
    Clavero-Jimeno, Antonio
    Garcia-Pinillos, Felipe
    SPORTS ENGINEERING, 2022, 25 (01)